Three Phase Active Shunt Power Filter with Simple Control in PSIM Simulation

Generally the electrical system used by many consumer and industry usually uses passive filter and capacitor bank to compensate, harmonics and reactive power absorbed by the loads .The passive filter and capacitor bank make harmonic resonance with input impedance so that magnitude of harmonic current increased with harmonic frequency generated by nonlinear load. In this paper a simple active filter with PSIM simulation model used, the reference current generated by simple method of power synchronous detection and gate pulses generated by the use of modulated hysteresis current controller. The proposed model compensates current harmonics, and it  does power factor correction. The active filter designed in PSIM software and control of active filter is done in Simulink environment. PSIM and MATLAB software is linked by Sim coupler. The capacitor voltage is maintained constant by using PI controller. Simulation results with PSIM software shows that the designed active filter is very effective in harmonic elimination and power factor correction Keywords: : Active filter, Modulated Hysteresis current control, power synchronous detection (PSD),current harmonics, Pulse Width Modulation, , PSIM software

[1]  Hirofumi Akagi,et al.  Trends in active power line conditioners , 1992, Proceedings of the 1992 International Conference on Industrial Electronics, Control, Instrumentation, and Automation.

[2]  V. Agarwal,et al.  A DSP Based Optimal Algorithm for Shunt Active Filter Under Nonsinusoidal Supply and Unbalanced Load Conditions , 2007, IEEE Transactions on Power Electronics.

[3]  Sergio Alejandro Gonzalez,et al.  Harmonic Computation Technique Suitable for Active Power Filters , 2007, IEEE Transactions on Industrial Electronics.

[4]  E.R. Cadaval,et al.  Comparison of Control Strategies for Shunt Active Power Filters in Three-Phase Four-Wire Systems , 2007, IEEE Transactions on Power Electronics.

[5]  J. H. Marks,et al.  Control techniques for active power filters , 2005 .

[6]  Xu Wang,et al.  Control Techniques for Active Power Filters , 2010, 2010 International Conference on Electrical and Control Engineering.

[7]  S.J. Finney,et al.  Review of harmonic current extraction techniques for an active power filter , 2004, 2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951).

[8]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[9]  Marian P. Kazmierkowski,et al.  Current control techniques for three-phase voltage-source PWM converters: a survey , 1998, IEEE Trans. Ind. Electron..

[10]  G. W. Chang,et al.  Optimisation-based strategy for shunt active power filter control under non-ideal supply voltages , 2005 .