Minimizing the thermal losses from perfusion during focused ultrasound exposures with flowing microbubbles.

This paper demonstrated the use of flowing microbubbles (MBs) to minimize thermal losses from perfusion during focused ultrasound exposures due to acoustic cavitation. Temperature and cavitation were simultaneously investigated as MBs flowing through a wall-less flow phantom with varying flow velocities (2-55 cm/s) and concentrations (0%-0.1%) when exposed at different acoustic power levels (5-120 W). The peak temperature at the end of ultrasonic exposures in the flow and in the outer of the vessel as well as the cavitation were higher than those pure controls measured at the same exposure parameters and flow velocities but without MBs. All the peak temperatures initially increased with increasing flow velocities of MBs, followed by a decrease of the peak temperatures with increasing flow velocities when the velocity was higher than the inflection velocity. Meanwhile, cavitation showed a trend of increases with increasing flow velocity. The inflection velocity and cavitation increased with increasing acoustic power and MBs concentration. Thermal lesion appeared around the vessel as MBs flow through the vessel, at which lesion was not observed originally without MBs. These results suggested that this may provide an effective way to minimize thermal losses from perfusion during focused ultrasound exposures.

[1]  Zhao-You Tang,et al.  Iodized oil enhances the thermal effect of high-intensity focused ultrasound on ablating experimental liver cancer , 1997, Journal of Cancer Research and Clinical Oncology.

[2]  F V Gleeson,et al.  The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population , 2005, British Journal of Cancer.

[3]  Kenneth I Marro,et al.  Magnetic resonance imaging of boiling induced by high intensity focused ultrasound. , 2007, The Journal of the Acoustical Society of America.

[4]  Roxy Senior,et al.  Contrast echocardiography: evidence for clinical use. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[5]  Vesna Zderic,et al.  Biological and physical mechanisms of HIFU-induced hyperecho in ultrasound images. , 2006, Ultrasound in medicine & biology.

[6]  H. Nagawa,et al.  Heating and coagulation volume obtained with high-intensity focused ultrasound therapy: comparison of perflutren protein-type A microspheres and MRX-133 in rabbits. , 2005, Radiology.

[7]  Roy W. Martin,et al.  Hemorrhage control in arteries using high-intensity focused ultrasound: a survival study. , 2006, Ultrasonics.

[8]  Yao-Sheng Tung,et al.  Contrast-agent-enhanced ultrasound thermal ablation. , 2006, Ultrasound in medicine & biology.

[9]  F. Jolesz,et al.  Current status and future potential of MRI‐guided focused ultrasound surgery , 2008, Journal of magnetic resonance imaging : JMRI.

[10]  Zhen Xu,et al.  Effects of acoustic parameters on bubble cloud dynamics in ultrasound tissue erosion (histotripsy). , 2007, The Journal of the Acoustical Society of America.

[11]  G. Muto,et al.  Visually directed transrectal high intensity focused ultrasound for the treatment of prostate cancer: a preliminary report on the Italian experience. , 2009, The Journal of urology.

[12]  Xiaodong Zhou,et al.  Analysis of apoptosis and cell proliferation after high intensity-focused ultrasound ablation combined with microbubbles in rabbit livers , 2007, European journal of gastroenterology & hepatology.

[13]  Lawrence A Crum,et al.  Effects of nonlinear propagation, cavitation, and boiling in lesion formation by high intensity focused ultrasound in a gel phantom. , 2006, The Journal of the Acoustical Society of America.

[14]  Cheng Xu,et al.  Dynamic changes of integrated backscatter, attenuation coefficient and bubble activities during high-intensity focused ultrasound (HIFU) treatment. , 2009, Ultrasound in medicine & biology.

[15]  P. Dayton,et al.  Mechanisms of contrast agent destruction , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Vassilis Sboros,et al.  Response of contrast agents to ultrasound. , 2008, Advanced drug delivery reviews.

[17]  Laura Curiel,et al.  In vivo monitoring of focused ultrasound surgery using local harmonic motion. , 2009, Ultrasound in medicine & biology.

[18]  Christian Greis,et al.  Technology overview: SonoVue (Bracco, Milan). , 2004, European radiology.

[19]  Natalia Vykhodtseva,et al.  500‐element ultrasound phased array system for noninvasive focal surgery of the brain: A preliminary rabbit study with ex vivo human skulls , 2004, Magnetic resonance in medicine.

[20]  Kullervo Hynynen,et al.  Pre-clinical testing of a phased array ultrasound system for MRI-guided noninvasive surgery of the brain--a primate study. , 2006, European journal of radiology.

[21]  C R Hill,et al.  Lesion development in focused ultrasound surgery: a general model. , 1994, Ultrasound in medicine & biology.

[22]  Diane Dalecki,et al.  Ultrasonic excitation of a bubble inside a deformable tube: implications for ultrasonically induced hemorrhage. , 2008, The Journal of the Acoustical Society of America.

[23]  Flordeliza S Villanueva,et al.  Molecular imaging of cardiovascular disease using ultrasound , 2008, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[24]  D. Razansky,et al.  Enhanced heat deposition using ultrasound contrast agent - modeling and experimental observations , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[25]  Xiaodong Zhou,et al.  Ablation of High-Intensity Focused Ultrasound Assisted with SonoVue on Rabbit VX2 Liver Tumors: Sequential Findings with Histopathology, Immunohistochemistry, and Enzyme Histochemistry , 2009, Annals of Surgical Oncology.

[26]  Morton W. Miller,et al.  The pulse length-dependence of inertial cavitation dose and hemolysis. , 2003, Ultrasound in medicine & biology.

[27]  Win-Li Lin,et al.  Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption. , 2008, Ultrasonics sonochemistry.

[28]  Kazuaki Sasaki,et al.  In vivo acceleration of ultrasonic tissue heating by microbubble agent , 2005 .

[29]  Vesna Zderic,et al.  Gel phantom for use in high-intensity focused ultrasound dosimetry. , 2005, Ultrasound in medicine & biology.

[30]  F. Fry,et al.  Ultrasound and microbubbles: their generation, detection and potential utilization in tissue and organ therapy--experimental. , 1995, Ultrasound in medicine & biology.

[31]  Lawrence A Crum,et al.  Acoustic characterization of high intensity focused ultrasound fields: a combined measurement and modeling approach. , 2008, The Journal of the Acoustical Society of America.

[32]  Ronald A. Roy,et al.  Measurements of bubble-enhanced heating from focused, MHz-frequency ultrasound in a tissue-mimicking material. , 2001, Ultrasound in medicine & biology.

[33]  C. Lafon,et al.  Feasibility of using ultrasound contrast agents to increase the size of thermal lesions induced by non-focused transducers: in vitro demonstration in tissue mimicking phantom. , 2009, Ultrasonics.

[34]  J. Kennedy High-intensity focused ultrasound in the treatment of solid tumours , 2005, Nature Reviews Cancer.

[35]  Kenneth S. Suslick,et al.  Plasma formation and temperature measurement during single-bubble cavitation , 2005, Nature.

[36]  Kullervo Hynynen,et al.  Uterine leiomyomas: MR imaging-based thermometry and thermal dosimetry during focused ultrasound thermal ablation. , 2006, Radiology.

[37]  Sunita Chauhan,et al.  Multiple high-intensity focused ultrasound probes for kidney-tissue ablation. , 2005, Journal of endourology.

[38]  Gail ter Haar,et al.  Therapeutic applications of ultrasound. , 2007 .

[39]  Vera A. Khokhlova,et al.  Effect of acoustic nonlinearity on heating of biological tissue by high-intensity focused ultrasound , 2001 .

[40]  Ronald A. Roy,et al.  Experimental validation of a tractable numerical model for focused ultrasound heating in flow-through tissue phantoms. , 2004, The Journal of the Acoustical Society of America.

[41]  Feng Wu,et al.  Activation of tumor-infiltrating antigen presenting cells by high intensity focused ultrasound ablation of human breast cancer. , 2009, Ultrasound in medicine & biology.

[42]  Yoichiro Matsumoto,et al.  Use of a microbubble agent to increase the effects of high intensity focused ultrasound on liver tissue , 2005, European Radiology.

[43]  F. Gleeson,et al.  High-intensity focused ultrasound for the treatment of liver tumours. , 2004, Ultrasonics.

[44]  Katherine W Ferrara,et al.  Ultrasound contrast microbubbles in imaging and therapy: physical principles and engineering , 2009, Physics in medicine and biology.

[45]  Ian Rivens,et al.  Investigation of the viscous heating artefact arising from the use of thermocouples in a focused ultrasound field , 2008, Physics in medicine and biology.

[46]  Ronald A. Roy,et al.  Role of acoustic cavitation in the delivery and monitoring of cancer treatment by high-intensity focused ultrasound (HIFU) , 2007, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[47]  N. Tomita,et al.  Low‐intensity ultrasound and microbubbles enhance the antitumor effect of cisplatin , 2008, Cancer science.