Characterisation of micromechanically coupled U-shaped cantilever-based oscillators with and without micromechanical elements for synchronised oscillation-based applications

Two novel oscillation systems, consisting of a U-shaped cantilever and a beam-shaped cantilever, were designed, fabricated and comparatively characterised for synchronised oscillation-based applications. In the case of without mechanical elements, two geometrically different cantilevers, with resonant frequencies of 182.506 kHz (detecting) and 372.503 kHz (sensing), respectively, are coupled by two coupling overhangs. Under synchronised oscillation, the frequency response was found to double from 182.850 to 365.713 kHz from a low-frequency cantilever (U shaped) to a high-frequency cantilever (beam shaped). A plateau with a frequency ratio of 2.000 was observed for both systems, which corresponds to a stable synchronisation region. This demonstrates the possibility of increasing the frequency response signal from the low-frequency cantilever to the high-frequency cantilever based on this super harmonic synchronisation. However, based on the comparative studies of two systems with and without mechanical systems, it is found that enhancing the nonlinearity without increasing energy loss (support loss in the present study) seems to be necessary to widen the frequency entrainment range for real applications.

[1]  Ryutaro Maeda,et al.  Synchronized oscillation in micro mechanically coupled opposite C-shaped cantilever-based oscillator system , 2011, 2011 16th International Solid-State Sensors, Actuators and Microsystems Conference.

[2]  Masayoshi Esashi,et al.  Micromechanically-coupled resonated system for synchronized oscillation with improved phase noise , 2010, 2010 IEEE 23rd International Conference on Micro Electro Mechanical Systems (MEMS).

[3]  Jürgen Kurths,et al.  Synchronization: Phase locking and frequency entrainment , 2001 .

[4]  M. Roukes,et al.  Ultimate limits to inertial mass sensing based upon nanoelectromechanical systems , 2003, physics/0309075.

[5]  Brian H. Houston,et al.  Frequency entrainment for micromechanical oscillator , 2003 .

[6]  Masayoshi Esashi,et al.  Crystallographic influence on nanomechanics of (100)-oriented silicon resonators , 2003 .

[7]  M. Imboden,et al.  Synchronized Oscillation in Coupled Nanomechanical Oscillators , 2007, Science.

[8]  Daniel Rugar,et al.  Sub-attonewton force detection at millikelvin temperatures , 2001 .

[9]  Masayoshi Esashi,et al.  Mass sensing with resonating ultrathin double beams , 2003, Proceedings of IEEE Sensors 2003 (IEEE Cat. No.03CH37498).

[10]  M. Sepaniak,et al.  Cantilever transducers as a platform for chemical and biological sensors , 2004 .

[11]  M. Roukes,et al.  Noise processes in nanomechanical resonators , 2002 .

[12]  D. Rugar,et al.  Frequency modulation detection using high‐Q cantilevers for enhanced force microscope sensitivity , 1991 .

[13]  Masayoshi Esashi,et al.  Time dependence of energy dissipation in resonating silicon cantilevers in ultrahigh vacuum , 2003 .

[14]  T. Kenny,et al.  Attonewton force detection using ultrathin silicon cantilevers , 1997 .

[15]  Masayoshi Esashi,et al.  Thermal treatments and gas adsorption influences on nanomechanics of ultra-thin silicon resonators for ultimate sensing , 2004 .

[16]  Jürgen Kurths,et al.  Synchronization - A Universal Concept in Nonlinear Sciences , 2001, Cambridge Nonlinear Science Series.