In vivo quantitation of water content in muscle tissues by NMR imaging.

The water contents of phantoms and muscle tissues were determined directly from NMR imaging experiments. The method involves the calculation of corrected proton densities using relaxation time determinations and suitable calibration phantoms. Comparison with the values obtained from the oven-dry method yields good agreement in normal rat skeletal tissue and in rats injected with red blood cells from sickle cell patients.

[1]  C. Durney,et al.  Assessment of lung water distribution by nuclear magnetic resonance. A new method for quantifying and monitoring experimental lung injury. , 1988, The American review of respiratory disease.

[2]  F. Smith,et al.  Measurement of total lung water from nuclear magnetic resonance images. , 1986, The British journal of radiology.

[3]  J. Ford,et al.  Accurate T2 NMR images. , 1983, Medical physics.

[4]  S. Holland,et al.  Modeling sickle cell vasoocclusion in the rat leg: quantification of trapped sickle cells and correlation with 31P metabolic and 1H magnetic resonance imaging changes. , 1989, Proceedings of the National Academy of Sciences of the United States of America.

[5]  C. Durney,et al.  Lung water quantitation by nuclear magnetic resonance imaging. , 1982, Science.

[6]  T. Conturo,et al.  Improved determination of spin density, T1 and T2 from a three-parameter fit to multiple-delay-multiple-echo (MDME) NMR images. , 1986, Physics in medicine and biology.

[7]  B R Rosen,et al.  Spin lattice relaxation time measurements in two-dimensional nuclear magnetic resonance imaging: corrections for plane selection and pulse sequence. , 1984, Journal of computer assisted tomography.

[8]  J. Ford,et al.  Accurate T1 and spin density NMR images. , 1985, Medical physics.

[9]  R. Kurland,et al.  Effect of induced field inhomogeneity on transverse proton NMR relaxation in tissue water and model systems , 1986, Magnetic resonance in medicine.

[10]  C N de Graaf,et al.  Precision in calculated rho, T1 and T2 images as a function of data analysis method. , 1988, Magnetic resonance imaging.

[11]  J C Gore,et al.  Effects of selective pulses on the measurement of T2 and apparent diffusion in multiecho MRI , 1987, Magnetic resonance in medicine.

[12]  C. N. de Graaf,et al.  Derivation of quantitative information in NMR imaging: a phantom study , 1984 .

[13]  I. Young,et al.  Variations in slice shape and absorption as artifacts in the determination of tissue parameters in NMR imaging , 1985, Magnetic resonance in medicine.

[14]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[15]  J C Gore,et al.  Errors in the measurements of T2 using multiple‐echo MRI techniques. I. Effects of radiofrequency pulse imperfections , 1986, Magnetic resonance in medicine.

[16]  K Straughan,et al.  Calibration of proton density measurements in nuclear magnetic resonance imaging. , 1984, Physics in medicine and biology.

[17]  J C Gore,et al.  Toward an automated analysis system for nuclear magnetic resonance imaging. I. Efficient pulse sequences for simultaneous T1-T2 imaging. , 1986, Medical physics.

[18]  R. Nagel,et al.  Dense cells in sickle cell anemia: the effects of gene interaction. , 1984, Blood.

[19]  J A Koutcher,et al.  Accuracy and reproducibility of image derived relaxation times on a clinical 1.5 T magnetic resonance scanner. , 1989, Medical physics.

[20]  P. R. Moran A general approach to T1, T2, and spin-density discrimination sensitivities in NMR imaging sequences. , 1984, Magnetic resonance imaging.