Critical guidelines for validation of the selectivity of in-vivo chemical microsensors

Microsensors are miniaturized analytical devices for making in-situ chemical measurements in biological systems with extraordinary temporal resolution. Their most severe limitation is chemical selectivity. Here, we suggest guidelines that can be applied to a range of in-vivo microsensor applications for evaluation of analyte identification and improvement of selectivity.

[1]  Michel Jouvet,et al.  In vivo electrochemical detection of catechols in the neostriatum of anaesthetized rats: dopamine or DOPAC? , 1980, Nature.

[2]  P. Garris,et al.  Frequency of Dopamine Concentration Transients Increases in Dorsal and Ventral Striatum of Male Rats during Introduction of Conspecifics , 2002, The Journal of Neuroscience.

[3]  M. Rice,et al.  Simultaneous voltammetric and chemical monitoring of dopamine release in situ , 1985, Brain Research.

[4]  R. Wightman,et al.  Correlation of local changes in extracellular oxygen and pH that accompany dopaminergic terminal activity in the rat caudate–putamen , 2003, Journal of neurochemistry.

[5]  R. Mark Wightman,et al.  Interference by pH and Ca2+ ions during measurements of catecholamine release in slices of rat amygdala with fast-scan cyclic voltammetry , 1994, Journal of Neuroscience Methods.

[6]  P. Garris,et al.  pH-Dependent processes at Nafion®-coated carbon-fiber microelectrodes , 1993 .

[7]  Francois Pomerleau,et al.  Improved ceramic-based multisite microelectrode for rapid measurements of l-glutamate in the CNS , 2002, Journal of Neuroscience Methods.

[8]  G. Gerhardt,et al.  Effects of recording media composition on the responses of Nafion-coated carbon fiber microelectrodes measured using high-speed chronoamperometry , 2001, Journal of Neuroscience Methods.

[9]  M. Fillenz,et al.  An amperometric enzyme electrode for monitoring brain glucose in the freely moving rat , 1986, Neuroscience Letters.

[10]  Ralph N. Adams,et al.  Nafion-coated electrodes with high selectivity for CNS electrochemistry , 1984, Brain Research.

[11]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[12]  E. Pothos,et al.  Presynaptic Recording of Quanta from Midbrain Dopamine Neurons and Modulation of the Quantal Size , 1998, The Journal of Neuroscience.

[13]  R. Wightman,et al.  Subsecond adsorption and desorption of dopamine at carbon-fiber microelectrodes. , 2000, Analytical chemistry.

[14]  M. Rice,et al.  A new type of enzyme electrode: the ascorbic acid eliminator electrode. , 1982, Life sciences.

[15]  P. Garris,et al.  Sub-second changes in accumbal dopamine during sexual behavior in male rats , 2001, Neuroreport.

[16]  R. Adams,et al.  Electrochemical assay for brain ascorbate with ascorbate oxidase. , 1982, Analytical chemistry.

[17]  C. A. Marsden,et al.  In vivo voltammetry—Present electrodes and methods , 1988, Neuroscience.

[18]  M. Rice,et al.  Dependence of dopamine calibration factors on media Ca2+ and Mg2+ at carbon-fiber microelectrodes used with fast-scan cyclic voltammetry , 1998, Journal of Neuroscience Methods.

[19]  N. Kulagina,et al.  Monitoring glutamate and ascorbate in the extracellular space of brain tissue with electrochemical microsensors. , 1999, Analytical chemistry.

[20]  G. Gerhardt,et al.  Self-referencing ceramic-based multisite microelectrodes for the detection and elimination of interferences from the measurement of L-glutamate and other analytes. , 2001, Analytical chemistry.

[21]  R. Wightman,et al.  Subsecond dopamine release promotes cocaine seeking , 2003, Nature.

[22]  G. S. Wilson,et al.  Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring. , 1991, Analytical chemistry.

[23]  J. A. Jankowski,et al.  Temporally resolved catecholamine spikes correspond to single vesicle release from individual chromaffin cells. , 1991, Proceedings of the National Academy of Sciences of the United States of America.