[Patient-ventilator interaction].

Mechanically ventilated patients interact with ventilator functions at different levels such as triggering of the ventilator, pressurization and cycling from inspiration to expiration. Patient ventilator asynchrony in any one of these phase results in fighting with ventilator, increase in work of breathing and respiratory muscle fatigue. Patient ventilator dyssynchrony occurs when gas delivery from the ventilator does not match with the neural output of the respiratory center. The clinical findings of patient-ventilator asynchrony are; use of accessory respiratory muscle, tachypnea, tachycardia, active expiration, diaphoresis and observation of asynchrony between patient respiratory effort and the ventilator waveforms. Among the patients with dynamic hyperinflation such as chronic obstructive pulmonary disease the most frequent causes of patient-ventilator asynchrony are trigger and expiratory asynchronies. In acute respiratory distress syndrome patient-ventilator asynchrony may develop due to problems in triggering or asynchrony in flow and inspiration-expiration cycle. Patient-ventilator interaction during noninvasive mechanical ventilation may be affected by the type of masks used, ventilator types, ventilation modes and parameters, humidification and sedation. Among the different patient groups it is important to know causes and solutions of patient-ventilator asynchrony problems. By this way patient will adapt ventilator and then dyspnea, ineffective respiratory effort and work of breathing may decrease subsequently.

[1]  Jon O Nilsestuen,et al.  Using ventilator graphics to identify patient-ventilator asynchrony. , 2005, Respiratory care.

[2]  P. Pelosi,et al.  The effects of pressurization rate on breathing pattern, work of breathing, gas exchange and patient comfort in pressure support ventilation. , 2001, The European respiratory journal.

[3]  M. Tobin,et al.  Effect of imposed inflation time on respiratory frequency and hyperinflation in patients with chronic obstructive pulmonary disease. , 2001, American journal of respiratory and critical care medicine.

[4]  R. Kallet,et al.  Effects of tidal volume on work of breathing during lung-protective ventilation in patients with acute lung injury and acute respiratory distress syndrome* , 2006, Critical care medicine.

[5]  G. Rubenfeld,et al.  Low tidal volume ventilation does not increase sedation use in patients with acute lung injury* , 2005, Critical care medicine.

[6]  P. Gay,et al.  Noninvasive proportional assist ventilation for acute respiratory insufficiency. Comparison with pressure support ventilation. , 2001, American journal of respiratory and critical care medicine.

[7]  D. Hess,et al.  Conventional mechanical ventilation in acute lung injury and acute respiratory distress syndrome. , 2006, Clinics in chest medicine.

[8]  L. Brochard,et al.  Effects of flow triggering on breathing effort during partial ventilatory support. , 1998, American journal of respiratory and critical care medicine.

[9]  V. Ranieri,et al.  Patient-ventilator interaction and sleep in mechanically ventilated patients: Pressure support versus proportional assist ventilation* , 2007, Critical care medicine.

[10]  A. Cuvelier,et al.  Asynchrony and Cyclic Variability in Pressure Support Ventilation , 2010 .

[11]  L. Brochard,et al.  Effect of the humidification device on the work of breathing during noninvasive ventilation , 2002, Intensive Care Medicine.

[12]  V. Ranieri,et al.  Inspiratory effort and measurement of dynamic intrinsic PEEP in COPD patients: Effects of ventilator triggering systems , 1995, Intensive Care Medicine.

[13]  Kalok C. Lee,et al.  Noninvasive ventilator triggering in chronic obstructive pulmonary disease. A test lung comparison. , 2001, American journal of respiratory and critical care medicine.

[14]  Jesse B. Hall,et al.  The relationship between sedative infusion requirements and permissive hypercapnia in critically ill, mechanically ventilated patients* , 2006, Critical care medicine.

[15]  S. Parthasarathy,et al.  Mechanical ventilation: let us minimize sleep disturbances , 2007, Current opinion in critical care.

[16]  P. Pelosi,et al.  Effect of different cycling-off criteria and positive end-expiratory pressure during pressure support ventilation in patients with chronic obstructive pulmonary disease* , 2007, Critical care medicine.

[17]  S. Parthasarathy,et al.  Cycling of inspiratory and expiratory muscle groups with the ventilator in airflow limitation. , 1998, American journal of respiratory and critical care medicine.

[18]  C. Gregoretti,et al.  Patient-ventilator asynchrony during noninvasive ventilation: the role of expiratory trigger , 1999, Intensive Care Medicine.

[19]  M. Tobin,et al.  Variability of patient-ventilator interaction with pressure support ventilation in patients with chronic obstructive pulmonary disease. , 1995, American journal of respiratory and critical care medicine.

[20]  E. Kondili,et al.  Effects of the flow waveform method of triggering and cycling on patient-ventilator interaction during pressure support , 2003, Intensive Care Medicine.

[21]  S. Parthasarathy,et al.  Effect of ventilator mode on sleep quality in critically ill patients. , 2002, American journal of respiratory and critical care medicine.

[22]  M. Younes,et al.  Effect of inspiratory flow rate on respiratory output in normal subjects. , 1992, The American review of respiratory disease.

[23]  S. Nava,et al.  Physiological effects of flow and pressure triggering during non-invasive mechanical ventilation in patients with chronic obstructive pulmonary disease. , 1997, Thorax.

[24]  D. Tassaux,et al.  Clinical review: Patient-ventilator interaction in chronic obstructive pulmonary disease , 2006, Critical care.

[25]  R. Pearl,et al.  Flow triggering, pressure triggering, and autotriggering during mechanical ventilation. , 2000, Critical care medicine.

[26]  P E Pepe,et al.  Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction: the auto-PEEP effect. , 1982, The American review of respiratory disease.

[27]  E. Kondili,et al.  Bedside waveforms interpretation as a tool to identify patient-ventilator asynchronies , 2005, Intensive Care Medicine.

[28]  Masaji Nishimura,et al.  Autotriggering caused by cardiogenic oscillation during flow‐triggered mechanical ventilation , 2000, Critical care medicine.

[29]  M J Tobin,et al.  Comparison of assisted ventilator modes on triggering, patient effort, and dyspnea. , 1997, American journal of respiratory and critical care medicine.

[30]  M J Tobin,et al.  Assessment of neural inspiratory time in ventilator-supported patients. , 2000, American journal of respiratory and critical care medicine.

[31]  M. Tobin,et al.  Influence of ventilator settings in determining respiratory frequency during mechanical ventilation. , 1999, American journal of respiratory and critical care medicine.

[32]  B. Thompson,et al.  Acute effects of tidal volume strategy on hemodynamics, fluid balance, and sedation in acute lung injury* , 2005, Critical care medicine.

[33]  S. Nava,et al.  Effects of different ventilator settings on sleep and inspiratory effort in patients with neuromuscular disease. , 2005, American journal of respiratory and critical care medicine.

[34]  S. Nava,et al.  Respiratory response and inspiratory effort during pressure support ventilation in COPD patients , 1995, Intensive Care Medicine.

[35]  J. Acosta-Escribano,et al.  Noninvasive pressure support versus proportional assist ventilation in acute respiratory failure , 2003, Intensive Care Medicine.

[36]  Marc Gainnier,et al.  Impact of expiratory trigger setting on delayed cycling and inspiratory muscle workload. , 2005, American journal of respiratory and critical care medicine.