DFIG based standalone power system operating at low load conditions.

The comparison of inductive and capacitive filter for standalone variable speed operated doubly fed induction generator DFIG is presented in the paper. Simulation and experimental results of both methods of filtration are shown. The model equations with stator connected filtering capacitors are analyzed. Sensorless control of the stator voltage vector in the polar frame is described. PLL based frequency control of generated stator voltage is presented. Modification of the control system allow for faster synchronization of the actual and reference voltage vector, what provide shorter start-up procedure of the system and better stabilization especially at low load conditions. Simulation and experimental results of improved frequency control of the standalone doubly fed induction generator are presented.

[1]  Hirofumi Akagi,et al.  Control and performance of a doubly-fed induction machine intended for a flywheel energy storage system , 2002 .

[2]  Benoit Robyns,et al.  Variable Speed Small Hydro Power Plant Connected to AC Grid or Isolated Loads , 2008 .

[3]  Wlodzimierz Koczara,et al.  DFIG-Based Power Generation System With UPS Function for Variable-Speed Applications , 2008, IEEE Transactions on Industrial Electronics.

[4]  W. Koczara,et al.  Rotor current PI controllers in the method of output voltage control of variable speed standalone DFIG , 2008, 2008 IEEE International Symposium on Industrial Electronics.

[5]  T. Kuwabara,et al.  Design and dynamic response characteristics of 400 MW adjustable speed pumped storage unit for Ohkawachi Power Station , 1996 .

[6]  Amit K. Jain,et al.  Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid , 2008, IEEE Transactions on Industrial Electronics.

[7]  Y. Kawabata,et al.  Variable speed constant frequency stand-alone power generator using wound-rotor induction machine , 2004, The 4th International Power Electronics and Motion Control Conference, 2004. IPEMC 2004..

[8]  I. Erlich,et al.  MODELING AND DYNAMIC SIMULATION OF VARIABLE SPEED PUMP STORAGE UNITS INCORPORATED INTO THE GERMAN ELECTRIC POWER SYSTEM , 2001 .

[9]  T. Yanagisawa,et al.  Successful achievement in a variable speed pumped storage power system at Yagisawa power plant , 1993, Conference Record of the Power Conversion Conference - Yokohama 1993.

[10]  J. Clare,et al.  MRAS observer for sensorless control of standalone doubly fed induction generators , 2005, IEEE Transactions on Energy Conversion.