Accuracy of a step counter during treadmill and daily life walking by healthy adults and patients with cardiac disease

Background Step counters have been used to observe activity and support physical activity, but there is limited evidence on their accuracy. Objective The purpose was to investigate the step accuracy of the Fitbit Zip (Zip) in healthy adults during treadmill walking and in patients with cardiac disease while hospitalised at home. Methods Twenty healthy adults aged 39±13.79 (mean ±SD) wore four Zips while walking on a treadmill at different speeds (1.7–6.1 km/hour), and 24 patients with cardiac disease (age 67±10.03) wore a Zip for 24 hours during hospitalisation and for 4 weeks thereafter at home. A Shimmer3 device was used as a criterion standard. Results At a treadmill speed of 3.6 km/hour, the relative error (±SD) for the Zips on the upper body was −0.02±0.67 on the right side and −0.09 (0.67) on the left side. For the Zips on the waist, this was 0.08±0.71 for the right side and -0.08 (0.47) on the left side. At a treadmill speed of 3.6 km/hour and higher, the average per cent of relative error was <3%. The 24-hour test for the hospitalised patients showed a relative error of −47.15±24.11 (interclass correlation coefficient (ICC): 0.60), and for the 24-hour test at home, the relative error was −27.51±28.78 (ICC: 0.87). Thus, none of the 24-hour tests had less than the expected 20% error. In time periods of evident walking during the 24 h test, the Zip had an average per cent relative error of <3% at 3.6 km/hour and higher speeds. Conclusions A speed of 3.6 km/hour or higher is required to expect acceptable accuracy in step measurement using a Zip, on a treadmill and in real life. Inaccuracies are directly related to slow speeds, which might be a problem for patients with cardiac disease who walk at a slow pace.

[1]  Kerenaftali Klein,et al.  Gait speed in ambulant older people in long term care: a systematic review and meta-analysis. , 2014, Journal of the American Medical Directors Association.

[2]  S. Trost,et al.  Clinical use of objective measures of physical activity , 2013, British Journal of Sports Medicine.

[3]  J. Spence,et al.  Examining the Steps-Per-Day Trajectories of Cardiac Rehabilitation Patients: A LATENT CLASS GROWTH ANALYSIS PERSPECTIVE , 2014, Journal of cardiopulmonary rehabilitation and prevention.

[4]  L. Neubeck,et al.  Validation of Fitbit-Flex as a measure of free-living physical activity in a community-based phase III cardiac rehabilitation population , 2016, European journal of preventive cardiology.

[5]  Anthony S Leicht,et al.  Influence of non-level walking on pedometer accuracy. , 2009, Journal of science and medicine in sport.

[6]  Matthew P Buman,et al.  Twenty-four Hours of Sleep, Sedentary Behavior, and Physical Activity with Nine Wearable Devices. , 2016, Medicine and science in sports and exercise.

[7]  J. Schwartz,et al.  Abstract MP11: Fitbit: An Accurate and Reliable Device for Wireless Physical Activity Tracking , 2015 .

[8]  Catrine Tudor-Locke,et al.  Evaluation of Quality of Commercial Pedometers , 2006, Canadian Journal of Public Health.

[9]  J. Naslund,et al.  Feasibility of popular m-health technologies for activity tracking among individuals with serious mental illness. , 2015, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[10]  Adolfo Muñoz,et al.  The Usefulness of Activity Trackers in Elderly with Reduced Mobility: A Case Study , 2013, MedInfo.

[11]  K. Filion,et al.  Efficacy of exercise-based cardiac rehabilitation post-myocardial infarction: a systematic review and meta-analysis of randomized controlled trials. , 2011, American heart journal.

[12]  George D Fulk,et al.  Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury , 2013, Physical Therapy.

[13]  Hirofumi Tanaka,et al.  Effect of walking speed and placement position interactions in determining the accuracy of various newer pedometers , 2014 .

[14]  Scott E Crouter,et al.  Accuracy and reliability of 10 pedometers for measuring steps over a 400-m walk. , 2003, Medicine and science in sports and exercise.

[15]  Fernando Costa,et al.  Exercise and physical activity in the prevention and treatment of atherosclerotic cardiovascular disease: a statement from the Council on Clinical Cardiology (Subcommittee on Exercise, Rehabilitation, and Prevention) and the Council on Nutrition, Physical Activity, and Metabolism (Subcommittee on Ph , 2003, Circulation.

[16]  R Senden,et al.  Importance of correcting for individual differences in the clinical diagnosis of gait disorders. , 2012, Physiotherapy.

[17]  Elizabeth J. Lyons,et al.  Using an electronic activity monitor system as an intervention modality: A systematic review , 2015, BMC Public Health.

[18]  C. F. Pedersen,et al.  An Evaluation of Commercial Pedometers for Monitoring Slow Walking Speed Populations. , 2016, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.

[19]  G. Cardon,et al.  Non-traditional wearing positions of pedometers: validity and reliability of the Omron HJ-203-ED pedometer under controlled and free-living conditions. , 2012, Journal of science and medicine in sport.

[20]  Scott J Strath,et al.  Accuracy of uploadable pedometers in laboratory, overground, and free-living conditions in young and older adults , 2012, International Journal of Behavioral Nutrition and Physical Activity.

[21]  A. Schmidt-Trucksäss,et al.  Pedometer accuracy in patients with chronic heart failure. , 2010, International journal of sports medicine.

[22]  B. Franklin,et al.  American College of Sports Medicine position stand. Quantity and quality of exercise for developing and maintaining cardiorespiratory, musculoskeletal, and neuromotor fitness in apparently healthy adults: guidance for prescribing exercise. , 2011, Medicine and science in sports and exercise.

[23]  Robert Shapiro,et al.  A comprehensive evaluation of motion sensor step-counting error. , 2011, Applied physiology, nutrition, and metabolism = Physiologie appliquee, nutrition et metabolisme.

[24]  Gabriel A. Koepp,et al.  "Go4Life" exercise counseling, accelerometer feedback, and activity levels in older people. , 2014, Archives of gerontology and geriatrics.

[25]  S. Trost,et al.  Evaluating the Responsiveness of Accelerometry to Detect Change in Physical Activity , 2014, Measurement in physical education and exercise science.

[26]  S. Ebrahim,et al.  Exercise-based cardiac rehabilitation for coronary heart disease. , 2016, The Cochrane database of systematic reviews.

[27]  Shaw Bronner,et al.  Comparison of steps and energy expenditure assessment in adults of Fitbit Tracker and Ultra to the Actical and indirect calorimetry , 2013, Journal of medical engineering & technology.

[28]  I. Olkin,et al.  Using pedometers to increase physical activity and improve health: a systematic review. , 2007, JAMA.

[29]  S. Clemes,et al.  Evaluation of a commercially available pedometer used to promote physical activity as part of a national programme , 2009, British Journal of Sports Medicine.

[30]  Maggie Killington,et al.  Accuracy of the FitBit at walking speeds and cadences relevant to clinical rehabilitation populations. , 2016, Disability and health journal.

[31]  Tim Olds,et al.  The validity of consumer-level, activity monitors in healthy adults worn in free-living conditions: a cross-sectional study , 2015, International Journal of Behavioral Nutrition and Physical Activity.

[32]  David E. Goodrich,et al.  Adverse events among high-risk participants in a home-based walking study: a descriptive study , 2007, The international journal of behavioral nutrition and physical activity.

[33]  Mark A Tully,et al.  The validation of Fibit Zip™ physical activity monitor as a measure of free-living physical activity , 2014, BMC Research Notes.

[34]  R. Kenny,et al.  Diurnal variations in the outcomes of instrumented gait and quiet standing balance assessments and their association with falls history , 2012, Physiological measurement.

[35]  C. Mazzà,et al.  Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors , 2015, PloS one.

[36]  P. Poirier,et al.  Daily Steps Threshold to Improve Cardiovascular Disease Risk Factors During the Year After an Acute Coronary Syndrome , 2013, Journal of cardiopulmonary rehabilitation and prevention.

[37]  Thea J. M. Kooiman,et al.  Reliability and validity of ten consumer activity trackers , 2015, BMC Sports Science, Medicine and Rehabilitation.

[38]  Brian Caulfield,et al.  SHIMMER: A new tool for temporal gait analysis , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[39]  D. Bassett,et al.  Pedometer measures of free-living physical activity: comparison of 13 models. , 2004, Medicine and science in sports and exercise.

[40]  Michael Weis,et al.  Accelerometer-based quantification of 6-minute walk test performance in patients with chronic heart failure: applicability in telemedicine. , 2009, Journal of cardiac failure.

[41]  Gavin Sandercock,et al.  Influence of step length on 6-minute walk test performance in patients with chronic heart failure. , 2012, Physiotherapy.

[42]  Sandra Prescher,et al.  Tele-accelerometry as a novel technique for assessing functional status in patients with heart failure: feasibility, reliability and patient safety. , 2013, International Journal of Cardiology.

[43]  Jesse Dallery,et al.  Internet-based contingency management increases walking in sedentary adults. , 2013, Journal of applied behavior analysis.

[44]  M. Granat,et al.  The validity and reliability of a novel activity monitor as a measure of walking , 2006, British Journal of Sports Medicine.

[45]  J. Takács,et al.  Validation of the Fitbit One activity monitor device during treadmill walking. , 2014, Journal of science and medicine in sport.

[46]  S. Ebrahim,et al.  Exercise based rehabilitation for heart failure. , 2004, The Cochrane database of systematic reviews.