Phase contrast electron microscopy: development of thin-film phase plates and biological applications

Phase contrast transmission electron microscopy (TEM) based on thin-film phase plates has been developed and applied to biological systems. Currently, development is focused on two techniques that employ two different types of phase plates. The first technique uses a Zernike phase plate, which is made of a uniform amorphous carbon film that completely covers the aperture of an objective lens and can retard the phase of electron waves by π/2, except at the centre where a tiny hole is drilled. The other technique uses a Hilbert phase plate, which is made of an amorphous carbon film that is twice as thick as the Zernike phase plate, covers only half of the aperture and retards the electron wave phase by π. By combining the power of efficient phase contrast detection with the accurate preservation achieved by a cryotechnique such as vitrification, macromolecular complexes and supermolecular structures inside intact bacterial or eukaryotic cells may be visualized without staining. Phase contrast cryo-TEM has the potential to bridge the gap between cellular and molecular biology in terms of high-resolution visualization. Examples using proteins, viruses, cyanobacteria and somatic cells are provided.

[1]  O. Scherzer The Theoretical Resolution Limit of the Electron Microscope , 1949 .

[2]  M. Setou,et al.  Mammalian cell nano structures visualized by cryo Hilbert differential contrast transmission electron microscopy , 2006, Medical Molecular Morphology.

[3]  D. Parsons,et al.  Enhanced contrast in electron microscopy of unstained biological material: II. Defocused contrast of large objects , 1970, Journal of microscopy.

[4]  J. Dubochet,et al.  Electron microscopy of frozen water and aqueous solutions , 1982 .

[5]  Grant J Jensen,et al.  A comparison of liquid nitrogen and liquid helium as cryogens for electron cryotomography. , 2006, Journal of structural biology.

[6]  E. Ramberg Phase Contrast in Electron Microscope Images , 1949 .

[7]  Radostin Danev,et al.  Zernike phase contrast electron microscopy of ice-embedded influenza A virus. , 2008, Journal of structural biology.

[8]  H. Heide Design and operation of cold stages , 1982 .

[9]  B. Gowen,et al.  ATP-Bound States of GroEL Captured by Cryo-Electron Microscopy , 2001, Cell.

[10]  F. Zernike Phase contrast, a new method for the microscopic observation of transparent objects , 1942 .

[11]  W. Chiu,et al.  Seeing GroEL at 6 A resolution by single particle electron cryomicroscopy. , 2004, Structure.

[12]  W. Mccrone Single Particle Analysis , 1973 .

[13]  J. Heuser,et al.  Procedure for freeze-drying molecules adsorbed to mica flakes. , 1983, Journal of molecular biology.

[14]  W. Chiu Electron microscopy of frozen, hydrated biological specimens. , 1986, Annual review of biophysics and biophysical chemistry.

[15]  A S Frangakis,et al.  Toward detecting and identifying macromolecules in a cellular context: template matching applied to electron tomograms. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[16]  K. Nagayama,et al.  Complex Observation in electron microscopy: IV. Reconstruction of Complex object wave from conventional and half plane phase plate image pair , 2004 .

[17]  K. M. Zinn,et al.  Transmission electron microscopy. , 1973, International ophthalmology clinics.

[18]  Serge Lowenthal,et al.  OBSERVATION OF PHASE OBJECTS BY OPTICALLY PROCESSED HILBERT TRANSFORM , 1967 .

[19]  K. Nagayama,et al.  Single particle analysis based on Zernike phase contrast transmission electron microscopy. , 2008, Journal of structural biology.

[20]  広 久保田,et al.  Principle of Optics , 1960 .

[21]  Kenneth H Downing,et al.  Dose tolerance at helium and nitrogen temperatures for whole cell electron tomography. , 2005, Journal of structural biology.

[22]  M. Dennis,et al.  Synaptic vesicle exocytosis captured by quick freezing and correlated with quantal transmitter release , 1979, The Journal of cell biology.

[23]  K. Nagayama Phase Contrast Enhancement with Phase Plates in Electron Microscopy , 2005 .

[24]  Y. Hiroaki,et al.  The TRPC3 channel has a large internal chamber surrounded by signal sensing antennas. , 2007, Journal of molecular biology.

[25]  H. Saibil,et al.  Allosteric signaling of ATP hydrolysis in GroEL–GroES complexes , 2006, Nature Structural &Molecular Biology.

[26]  H. Fernández-morán LOW‐TEMPERATURE PREPARATION TECHNIQUES FOR ELECTRON MICROSCOPY OF BIOLOGICAL SPECIMENS BASED ON RAPID FREEZING WITH LIQUID HELIUM II * , 1960, Annals of the New York Academy of Sciences.

[27]  K. Nagayama,et al.  Applicability of thin film phase plates in biological electron microscopy , 2006, Biophysics.

[28]  Lawrence Weiskrantz,et al.  Discussions and conclusions , 1998 .

[29]  D. Parsons,et al.  Possibility of a phase contrast electron microscope. , 1972, Applied optics.

[30]  David B. Williams,et al.  Transmission Electron Microscopy , 1996 .

[31]  K. Nagayama,et al.  Complex Observation in Electron Microscopy. II. Direct Visualization of Phases and Amplitudes of Exit Wave Functions , 2001 .

[32]  K. Nagayama,et al.  Transmission electron microscopy with Zernike phase plate. , 2001, Ultramicroscopy.

[33]  K. Nagayama Complex observation in electron microscopy. I. Basic scheme to surpass the Scherzer limit , 1999 .

[34]  J. Spence High-Resolution Electron Microscopy , 2003 .

[35]  K. Nagayama,et al.  Intact Carboxysomes in a Cyanobacterial Cell Visualized by Hilbert Differential Contrast Transmission Electron Microscopy , 2006, Journal of bacteriology.

[36]  Yoshinori Fujiyoshi,et al.  Development of a superfluid helium stage for high-resolution electron microscopy , 1991 .

[37]  K. Nagayama,et al.  A Novel Phase-contrast Transmission Electron Microscopy Producing High-contrast Topographic Images of Weak objects , 2002, Journal of biological physics.

[38]  K. Nagayama,et al.  In vivo subcellular ultrastructures recognized with Hilbert differential contrast transmission electron microscopy. , 2005, Journal of electron microscopy.

[39]  A. van Harreveld,et al.  Electron microscopy after rapid freezing on a metal surface and substitution fixation , 1964, The Anatomical record.

[40]  K. Nagayama,et al.  Transfer doublet and an elaborated phase plate holder for 120 kV electron-phase microscope. , 2005, Journal of electron microscopy.

[41]  K. Nagayama,et al.  Observation of in vivo DNA in Ice Embedded whole Cyanobacterial Cells by Hilbert Differential Contrast Transmission Electron Microscopy (HDC-TEM) , 2007 .