PEM-PET Image Reconstruction in a Clinically-Relevant Time Frame

A positron emission mammography-positron emission tomography (PEM-PET) system is being constructed for PET guidance of breast core biopsy. The system will have two orthogonal pairs of rotating planar detectors operating in coincidence mode, for which performing fully 3D image reconstruction in a clinically-relevant time frame is a challenge. This contribution describes a framework for fast list-mode ordered subsets expectation maximization (OSEM) iterative image reconstruction and two additional techniques to speed image reconstruction. First, a novel analytic approach to sensitivity normalization matrix calculation was developed. Second, parallelization was accomplished for sensitivity normalization matrix calculation and the iteration step of OSEM. The algorithm was tested using a Monte Carlo simulation of a 3 minute clinical PEM-PET acquisition for an ellipsoidal breast phantom with spherical tumors. Timing tests were made on two workstations, one with 2 CPUs and one with 4 dual core CPUs (8 effective processors). On the 8 processor system the sensitivity normalization matrix was computed in 21 sec and fully 3D image reconstruction with this precomputed sensitivity matrix was achieved in 4.6 min. Thus fully 3D iterative image reconstruction for PEM-PET in a clinical time frame is achievable.

[1]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[2]  J. Mulshine,et al.  Preliminary results for positron emission mammography: real-time functional breast imaging in a conventional mammography gantry , 1996, European Journal of Nuclear Medicine.

[3]  R. Wojcik,et al.  A large field of view positron emission mammography imager , 2002, 2002 IEEE Nuclear Science Symposium Conference Record.

[4]  S. Majewski,et al.  The potential role of positron emission mammography for detection of breast cancer. A phantom study. , 2000, Medical physics.

[5]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[6]  Christopher J. Thompson,et al.  Positron emission mammography (PEM): a promising technique for detecting breast cancer , 1995 .

[7]  H. Barrett,et al.  List-mode likelihood: EM algorithm and image quality estimation demonstrated on 2-D PET , 1998, IEEE Transactions on Medical Imaging.

[8]  S R Cherry,et al.  Design and evaluation of an LSO PET detector for breast cancer imaging. , 2000, Medical physics.

[9]  Jonathan S. Maltz,et al.  Development of the LBNL positron emission mammography camera , 2002 .

[10]  Andrew G. Weisenberger,et al.  Development of a dedicated positron emission tomography system for the detection and biopsy of breast cancer , 2006 .

[11]  Raymond R Raylman,et al.  Positron emission mammography with tomographic acquisition using dual planar detectors: initial evaluations. , 2004, Physics in medicine and biology.

[12]  Andrew J. Reader,et al.  One-pass list-mode EM algorithm for high-resolution 3-D PET image reconstruction into large arrays , 2002 .

[13]  H H Barrett,et al.  List-mode likelihood. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[14]  M Schwaiger,et al.  Breast imaging with fluorine-18-FDG PET: quantitative image analysis. , 1997, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  W. W. Moses,et al.  List-mode maximum-likelihood reconstruction applied to positron emission mammography (PEM) with irregular sampling , 2000, IEEE Transactions on Medical Imaging.

[16]  R L Wahl,et al.  Standardized uptake values of normal tissues at PET with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose: variations with body weight and a method for correction. , 1993, Radiology.