Near-infrared fluorescence contrast-enhanced imaging with area illumination and area detection: the forward imaging problem.

Fluorescence frequency-domain photon migration measurements were acquired from tissue phantoms, each containing a fluorescent target, by means of area illumination and area detection on the same surface and for the first time, to our knowledge, compared with predictions computed with a numerical solution to the coupled photon diffusion equations. We accomplished area illumination and area detection using a planar, intensity-modulated excitation light source and a gain-modulated intensified charge-coupled device camera, respectively. A 1-ml vessel containing 1-microm solution of Indocyanine Green in 1% Liposyn was immersed 1 cm deep in each 512-ml tissue phantom. For most tissue phantoms, the background surrounding the 1-ml target was composed of Liposyn solution containing Indocyanine Green or 3,3'-Diethylthiatricarbocyanine Iodide such that the target-to-background ratio of fluorescence yield was > or = 10:1. Measurements of fluorescence modulation amplitude and phase were predicted with a mean error ranging from 10.1% to 13.6% and 0.56 degrees to 1.72 degrees, respectively. These numbers are similar to those obtained by use of single-pixel frequency-domain photon migration techniques and validate the potential use of area illumination and area detection for biomedical imaging of tissues. Results also demonstrate that target-to-background ratios of fluorescence yield and fluorescence lifetime significantly affect target detectability.

[1]  Daniel J. Hawrysz,et al.  Three-dimensional, Bayesian image reconstruction from sparse and noisy data sets: Near-infrared fluorescence tomography , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[2]  J Lee,et al.  Error consideration in contrast-enhanced three-dimensional optical tomography. , 2001, Optics letters.

[3]  M G Nichols,et al.  Localization of Luminescent Inhomogeneities in Turbid Media with Spatially Resolved Measurements of cw Diffuse Luminescence Emittance. , 1998, Applied optics.

[4]  L. O. Svaasand,et al.  Boundary conditions for the diffusion equation in radiative transfer. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[5]  Anuradha Godavarty,et al.  Influence of the refractive index-mismatch at the boundaries measured in fluorescenceenhanced frequency-domain photon migration imaging. , 2002, Optics express.

[6]  A G Yodh,et al.  Fluorescent heterogeneities in turbid media: limits for detection, characterization, and comparison with absorption. , 1998, Applied optics.

[7]  J Wu,et al.  Time-resolved multichannel imaging of fluorescent objects embedded in turbid media. , 1995, Optics letters.

[8]  J. S. Reynolds,et al.  Measurement of the fluorescence lifetime in scattering media by frequency-domain photon migration. , 1999, Applied optics.

[9]  R. Weissleder,et al.  Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation. , 2001, Optics letters.

[10]  M J Eppstein,et al.  Biomedical optical tomography using dynamic parameterization and bayesian conditioning on photon migration measurements. , 1999, Applied optics.

[11]  M S Feld,et al.  Fluorescence tomographic imaging in turbid media using early-arriving photons and Laplace transforms. , 1997, Proceedings of the National Academy of Sciences of the United States of America.

[12]  E. Sevick-Muraca,et al.  Precise analysis of frequency domain photon migration measurement for characterization of concentrated colloidal suspensions , 2002 .

[13]  R. Anderson Polarized light examination and photography of the skin. , 1991, Archives of dermatology.

[14]  S. Jacques,et al.  Imaging superficial tissues with polarized light , 2000, Lasers in surgery and medicine.

[15]  Brian W. Pogue,et al.  Mathematical model for time-resolved and frequency-domain fluorescence spectroscopy in biological tissues. , 1994, Applied optics.

[16]  Eva M Sevick-Muraca,et al.  Three-dimensional fluorescence enhanced optical tomography using referenced frequency-domain photon migration measurements at emission and excitation wavelengths. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[17]  Israel Gannot,et al.  Inverse method 3-D reconstruction of localized in vivo fluorescence-application to Sjogren syndrome , 1999 .

[18]  E M Sevick-Muraca,et al.  Three-dimensional unconstrained and constrained image-reconstruction techniques applied to fluorescence, frequency-domain photon migration. , 2001, Applied optics.

[19]  J E Bugaj,et al.  Stabilization of the Optical Tracer Agent Indocyanine Green Using Noncovalent Interactions , 2000, Photochemistry and photobiology.

[20]  E Gratton,et al.  Experimental verification of a theory for the time-resolved fluorescence spectroscopy of thick tissues. , 1997, Applied optics.

[21]  R. Alfano,et al.  Optical polarization imaging. , 1997, Applied optics.

[22]  Eva M Sevick-Muraca,et al.  Near-infrared fluorescence contrast-enhanced imaging with intensified charge-coupled device homodyne detection: measurement precision and accuracy. , 2003, Journal of biomedical optics.

[23]  R. Weissleder,et al.  Charge-coupled-device based scanner for tomography of fluorescent near-infrared probes in turbid media. , 2002, Medical physics.

[24]  Anuradha Godavarty,et al.  Near- Infrared Fluorescence Imaging and Spectroscopy in Random Media and Tissues , 2003 .

[25]  John C. Adams,et al.  MUDPACK: Multigrid portable FORTRAN software for the efficient solution of linear elliptic partial d , 1989 .

[26]  C. L. Hutchinson,et al.  Fluorescence-lifetime determination in tissues or other scattering media from measurement of excitation and emission kinetics. , 1996, Applied optics.

[27]  Durian Influence of boundary reflection and refraction on diffusive photon transport. , 1994, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[28]  B. Wilson,et al.  Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. , 1989, Applied optics.

[29]  J. S. Reynolds,et al.  Multipixel Techniques for Frequency‐Domain Photon Migration Imaging , 1997, Biotechnology progress.

[30]  C. L. Hutchinson,et al.  Fluorescence and Absorption Contrast Mechanisms for Biomedical Optical Imaging Using Frequency‐Domain Techniques , 1997, Photochemistry and photobiology.