[Small animal image-guided radiotherapy: A new era for preclinical studies].
暂无分享,去创建一个
A.-M. Frelin-Labalme | Sophie Chiavassa | Gregory Delpon | S. Heinrich | V. Beaudouin | C. Noblet | M. Begue | C. Le Deroff | F. Pouzoulet | V. Beaudouin | C. Noblet | G. Delpon | S. Chiavassa | F. Pouzoulet | M. Bègue | S. Heinrich | A. Frelin-Labalme | C. L. Deroff
[1] Erik Tryggestad,et al. Small animal radiotherapy research platforms , 2011, Physics in medicine and biology.
[2] Mary Beth Tribble,et al. PTH1-34 alleviates radiotherapy-induced local bone loss by improving osteoblast and osteocyte survival. , 2014, Bone.
[3] P. Andreo,et al. Absorbed Dose Determination in External Beam Radiotherapy: An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water , 2001 .
[4] Peter Kazanzides,et al. High-resolution, small animal radiation research platform with x-ray tomographic guidance capabilities. , 2008, International journal of radiation oncology, biology, physics.
[5] Edward E Graves,et al. The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy. , 2011, Medical physics.
[6] N. Perichon,et al. The LNE-LNHB water calorimeter for primary measurement of absorbed dose at low depth in water: application to medium-energy x-rays , 2013, Physics in medicine and biology.
[7] K. Winston,et al. A system for stereotactic radiosurgery with a linear accelerator , 1988 .
[8] N. Perichon,et al. Comparison between absorbed dose to water standards established by water calorimetry at the LNE-LNHB and by application of international air-kerma based protocols for kilovoltage medium energy x-rays , 2013, Physics in medicine and biology.
[9] Frank Verhaegen,et al. A combined dose calculation and verification method for a small animal precision irradiator based on onboard imaging. , 2012, Medical physics.
[10] David A Jaffray,et al. Two-dimensional inverse planning and delivery with a preclinical image guided microirradiator. , 2013, Medical physics.
[11] S Stute,et al. GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy , 2011, Physics in medicine and biology.
[12] A. Nahum,et al. The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL; 10-300 kV generating potential). Institution of Physics and Engineering in Medicine and Biology. , 1996, Physics in medicine and biology.
[13] Peter Kazanzides,et al. Image-guided small animal radiation research platform: calibration of treatment beam alignment , 2009, Physics in medicine and biology.
[14] C. Hennequin,et al. Implications récentes des équipes françaises en oncologie radiothérapie et radiobiologie clinique , 2012 .
[15] Frank Verhaegen,et al. A review of treatment planning for precision image-guided photon beam pre-clinical animal radiation studies. , 2014, Zeitschrift fur medizinische Physik.
[16] Frank Verhaegen,et al. A longitudinal evaluation of partial lung irradiation in mice by using a dedicated image-guided small animal irradiator. , 2014, International journal of radiation oncology, biology, physics.
[17] Shiva K. Das,et al. Pilot Study Evaluating a Rat Model of Radiation-induced Erectile Dysfunction Using an Image-guided Microirradiator. , 2014, Urology.
[18] S M Seltzer,et al. AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology. , 2001, Medical physics.
[19] D A Jaffray,et al. Characterization of image quality and image-guidance performance of a preclinical microirradiator. , 2011, Medical physics.
[20] Christian Vanhove,et al. MRI-guided 3D conformal arc micro-irradiation of a F98 glioblastoma rat model using the Small Animal Radiation Research Platform (SARRP) , 2014, Journal of Neuro-Oncology.
[21] F. Eschwège,et al. [Hypofractionation and radiotherapy: "the eternal return"]. , 2013, Cancer radiotherapie : journal de la Societe francaise de radiotherapie oncologique.
[22] J. Kaas,et al. Multi-institutional dosimetric and geometric commissioning of image-guided small animal irradiators. , 2014, Medical physics.
[23] F Verhaegen,et al. A comprehensive system for dosimetric commissioning and Monte Carlo validation for the small animal radiation research platform , 2009, Physics in medicine and biology.
[24] Frank Verhaegen,et al. Development and validation of a treatment planning system for small animal radiotherapy: SmART-Plan. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.
[25] Paul J Keall,et al. A bone composition model for Monte Carlo x-ray transport simulations. , 2009, Medical physics.
[26] D. Jaffray. Image-guided radiotherapy: from current concept to future perspectives , 2012, Nature Reviews Clinical Oncology.
[27] Hristo N Nikolov,et al. A quality assurance phantom for the performance evaluation of volumetric micro-CT systems , 2007, Physics in medicine and biology.
[28] A. Micke,et al. Multichannel film dosimetry with nonuniformity correction. , 2011, Medical physics.