The standardized EEG electrode array of the IFCN

Standardized EEG electrode positions are essential for both clinical applications and research. The aim of this guideline is to update and expand the unifying nomenclature and standardized positioning for EEG scalp electrodes. Electrode positions were based on 20% and 10% of standardized measurements from anatomical landmarks on the skull. However, standard recordings do not cover the anterior and basal temporal lobes, which is the most frequent source of epileptogenic activity. Here, we propose a basic array of 25 electrodes including the inferior temporal chain, which should be used for all standard clinical recordings. The nomenclature in the basic array is consistent with the 10-10-system. High-density scalp EEG arrays (64-256 electrodes) allow source imaging with even sub-lobar precision. This supplementary exam should be requested whenever necessary, e.g. search for epileptogenic activity in negative standard EEG or for presurgical evaluation. In the near future, nomenclature for high density electrodes arrays beyond the 10-10 system needs to be defined, to allow comparison and standardized recordings across centers. Contrary to the established belief that smaller heads needs less electrodes, in young children at least as many electrodes as in adults should be applied due to smaller skull thickness and the risk of spatial aliasing.

[1]  Robert Oostenveld,et al.  The five percent electrode system for high-resolution EEG and ERP measurements , 2001, Clinical Neurophysiology.

[2]  Claudio Pollo,et al.  Electrical source imaging for presurgical focus localization in epilepsy patients with normal MRI , 2010, Epilepsia.

[3]  C D Binnie,et al.  Practical considerations in the positioning of EEG electrodes. , 1982, Electroencephalography and clinical neurophysiology.

[4]  Christoph M. Michel,et al.  Yield of MRI, high-density electric source imaging (HD-ESI), SPECT and PET in epilepsy surgery candidates , 2016, Clinical Neurophysiology.

[5]  H. Jasper,et al.  The ten-twenty electrode system of the International Federation. The International Federation of Clinical Neurophysiology. , 1999, Electroencephalography and clinical neurophysiology. Supplement.

[6]  Sándor Beniczky,et al.  Quantitative analysis of surface electromyography: Biomarkers for convulsive seizures , 2016, Clinical Neurophysiology.

[7]  Sándor Beniczky,et al.  Beyond the Double Banana: Improved Recognition of Temporal Lobe Seizures in Long-Term EEG , 2014, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[8]  Richard C. Burgess,et al.  Effects of eyelid closure, blinks, and eye movements on the electroencephalogram , 2005, Clinical Neurophysiology.

[9]  W. Freeman,et al.  Spatial spectra of scalp EEG and EMG from awake humans , 2003, Clinical Neurophysiology.

[10]  Jacques Felblinger,et al.  Automatic localization and labeling of EEG sensors (ALLES) in MRI volume , 2008, NeuroImage.

[11]  D. Lehmann,et al.  Low resolution electromagnetic tomography: a new method for localizing electrical activity in the brain. , 1994, International journal of psychophysiology : official journal of the International Organization of Psychophysiology.

[12]  Georgia Ramantani,et al.  Catching the Invisible: Mesial Temporal Source Contribution to Simultaneous EEG and SEEG Recordings , 2014, Brain Topography.

[13]  Taeun Chang,et al.  The American Clinical Neurophysiology Society's Guideline on Continuous Electroencephalography Monitoring in Neonates. , 2011, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[14]  Guideline Thirteen: Guidelines for Standard Electrode Position Nomenclature , 1994, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[15]  P. Ellen Grant,et al.  Effects of sutures and fontanels on MEG and EEG source analysis in a realistic infant head model , 2013, NeuroImage.

[16]  M. Cook,et al.  EEG source localization in focal epilepsy: Where are we now? , 2008, Epilepsia.

[17]  Anders M. Dale,et al.  Improved Localization of Cortical Activity By Combining EEG and MEG with MRI Cortical Surface Reconstruction , 2002 .

[18]  Sándor Beniczky,et al.  Patterns of muscle activation during generalized tonic and tonic–clonic epileptic seizures , 2011, Epilepsia.

[19]  Poul Jennum,et al.  Automated differentiation between epileptic and nonepileptic convulsive seizures , 2015, Annals of neurology.

[20]  Chang-Hwan Im,et al.  Detection of eye blink artifacts from single prefrontal channel electroencephalogram , 2016, Comput. Methods Programs Biomed..

[21]  C. Michel,et al.  The Role of Functional Neuroimaging in Pre-Surgical Epilepsy Evaluation , 2014, Front. Neurol..

[22]  Georgia Ramantani,et al.  Electrical source imaging in cortical malformation–related epilepsy: A prospective EEG‐SEEG concordance study , 2014, Epilepsia.

[23]  Christoph M. Michel,et al.  EEG mapping and source imaging , 2012 .

[24]  L. Koessler,et al.  Spatial localization of EEG electrodes , 2007, Neurophysiologie Clinique/Clinical Neurophysiology.

[25]  Lucy R. Sullivan,et al.  American Clinical Neurophysiology Society Guideline 5: Minimum Technical Standards for Pediatric Electroencephalography , 2016, The Neurodiagnostic journal.

[26]  Alpo Värri,et al.  Automatic detection of slow wave sleep using two channel electro-oculography , 2007, Journal of Neuroscience Methods.

[27]  Peter W. Kaplan,et al.  Consensus Statement on Continuous EEG in Critically Ill Adults and Children, Part II: Personnel, Technical Specifications, and Clinical Practice , 2015, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[28]  M. Hallett,et al.  Neurophysiology of myoclonus and progressive myoclonus epilepsies. , 2016, Epileptic disorders : international epilepsy journal with videotape.

[29]  Bin He,et al.  Dynamic imaging of ictal oscillations using non-invasive high-resolution EEG , 2011, NeuroImage.

[30]  B. He,et al.  Effect of EEG electrode number on epileptic source localization in pediatric patients , 2015, Clinical Neurophysiology.

[31]  Steve S. Chung,et al.  Ictal eye closure is a reliable indicator for psychogenic nonepileptic seizures , 2006, Neurology.

[32]  Yang Sheng,et al.  A Single Camera Photogrammetry System for Multi-angle Fast Localization of EEG Electrodes , 2011, Annals of Biomedical Engineering.

[33]  Silvia Brem,et al.  Automated detection and labeling of high-density EEG electrodes from structural MR images , 2016, Journal of neural engineering.

[34]  Gunnar Seemann,et al.  The Influence of Age and Skull Conductivity on Surface and Subdermal Bipolar EEG Leads , 2010, Comput. Intell. Neurosci..

[35]  Tammy N Tsuchida,et al.  American Clinical Neurophysiology Society Guideline 3: A Proposal for Standard Montages to Be Used in Clinical EEG , 2016, The Neurodiagnostic journal.

[36]  Christoph M. Michel,et al.  Epileptic source localization with high density EEG: how many electrodes are needed? , 2003, Clinical Neurophysiology.

[37]  P. V. van Rijen,et al.  Measurement of the Conductivity of Skull, Temporarily Removed During Epilepsy Surgery , 2004, Brain Topography.

[38]  C M Michel,et al.  Spatiotemporal EEG analysis and distributed source estimation in presurgical epilepsy evaluation. , 1999, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[39]  Claudio Pollo,et al.  Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients , 2011, Brain : a journal of neurology.

[40]  Toshimitsu Musha,et al.  Electric Dipole Tracing in the Brain by Means of the Boundary Element Method and Its Accuracy , 1987, IEEE Transactions on Biomedical Engineering.