Comparison of Loss in Single-Layer and Multi-Layer Windings with a DC Current Component

A common technique for reducing losses in high frequency windings is to use multiple conductor layers, each thin compared to a skin depth. This can be effective, but single-layer windings can also be advantageous for high frequency windings because their ac resistance goes up proportional to the square root of frequency, whereas the ac resistance of multi-layer windings can be proportional to the square of frequency. A general comparison of multi-layer and single-layer windings for applications with significant dc current shows that multi-layer windings can be effective in reducing loss in these applications, but achieving lower loss than a single-layer winding may require a large number of layers and may only produce a small improvement in loss

[1]  M. Perry,et al.  Multiple Layer Series Connected Winding Design for Minimum Losses , 1979, IEEE Transactions on Power Apparatus and Systems.

[2]  C.R. Sullivan Cost-constrained selection of strand diameter and number in a Litz-wire transformer winding , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[3]  M.E. Dale,et al.  Comparison of Single-Layer and Multi-Layer Windings with Physical Constraints or Strong Harmonics , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[4]  J. H. Spreen,et al.  Electrical terminal representation of conductor loss in transformers , 1990 .

[5]  M.E. Dale,et al.  General Comparison of Power Loss in Single-Layer and Multi-Layer Windings , 2005, 2005 IEEE 36th Power Electronics Specialists Conference.

[6]  G. A. Karvelis,et al.  Analysis and design of a novel nondissipative active clamp for forward converters , 2000, 2000 IEEE 31st Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.00CH37018).

[7]  Alex Van den Bossche,et al.  Inductors and Transformers for Power Electronics , 2005 .

[8]  Charles R. Sullivan Optimal choice for number of strands in a litz-wire transformer winding , 1997 .

[9]  Charles R. Sullivan,et al.  AC resistance of planar power inductors and the quasidistributed gap technique , 2001 .