Cooling of next generation computer chips: Parametric study for single- and two-phase cooling

The following study focuses on the scalability of single- and two-phase cooling techniques to address the cooling constraints and requirements of future vertically integrated chips. Water and refrigerant R134a were considered for single- and two-phase cooling respectively during simulations. A parametric study based on fin height, fin width and channel width of multi-microchannel heat removal structures was conducted for different power maps using an LTCM developed in-house code. Observations were made on junction temperature, pressure drop, and heat transfer coefficient behavior. Cooling structures with a fin height of 150 μm, fin width of 50 μm, and channel width of 100 μm showed sufficient cooling performance for homogeneous heat fluxes with 100 W/cm2 hot spots for both cooling techniques.

[1]  B. Michel,et al.  High Heat Flux Two-Phase Cooling in Silicon Multimicrochannels , 2008, IEEE Transactions on Components and Packaging Technologies.

[2]  Dimos Poulikakos,et al.  A novel high performance, ultra thin heat sink for electronics , 2010 .

[3]  Thomas Brunschwiler,et al.  Thermal Management of Vertically Integrated Packages , 2008 .

[4]  Thomas Brunschwiler,et al.  Experimental Investigation of an Ultrathin Manifold Microchannel Heat Sink for Liquid-Cooled Chips , 2010 .

[5]  J. Thome,et al.  Flow Boiling of R134a in a Multi-Microchannel Heat Sink With Hotspot Heaters for Energy-Efficient Microelectronic CPU Cooling Applications , 2011, IEEE Transactions on Components, Packaging and Manufacturing Technology.

[6]  R. Pease,et al.  High-performance heat sinking for VLSI , 1981, IEEE Electron Device Letters.

[7]  E. Colgan,et al.  A practical implementation of silicon microchannel coolers for high power chips , 2005, Semiconductor Thermal Measurement and Management IEEE Twenty First Annual IEEE Symposium, 2005..

[8]  J. Thome,et al.  State of the Art of High Heat Flux Cooling Technologies , 2007 .

[9]  B. Michel,et al.  Direct Liquid Jet-Impingment Cooling With Micron-Sized Nozzle Array and Distributed Return Architecture , 2006, Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems, 2006. ITHERM 2006..

[10]  Jackson Braz Marcinichen,et al.  Reasons to Use Two-phase Refrigerant Cooling , 2011 .