RF and Microwave Power Sensor Calibration by Direct Comparison Transfer

Many instruments can be used to measure radio frequency (RF) and microwave power. The most accurate one is a power sensor with a meter. The accuracy of RF and microwave power measurement depends on the accuracy of power sensor calibration. This chapter provides calibration methods of RF and microwave power sensor with system setup, modeling, equations, and analyses in different representations, traceability and measurement uncertainty evaluations. From the simple direct comparison transfer method, to the different improvements, and then the general analytical models, the methods provided in this chapter are useful for the guided-wave power sensor calibration in frequency range of a few MHz to several hundred GHz.

[1]  Fred R. Clague A Calibration Service for Coaxial Reference Standards for Microwave Power | NIST , 1995 .

[2]  G. H. Bryant Principles of Microwave Measurements , 1993 .

[3]  A. Fantom,et al.  Radio Frequency and Microwave Power Measurement , 1990 .

[4]  N. Ridler,et al.  Propagating S-parameter uncertainties to other measurement quantities , 2001, 58th ARFTG Conference Digest.

[5]  L. Brunetti,et al.  A new microcalorimeter for measurements in 3.5 mm coaxial line , 2002, CPEM 2002.

[6]  Xiaohai Cui,et al.  Comparison of experimental techniques for evaluating the correction factor of a rectangular waveguide microcalorimeter , 2010, CPEM 2010.

[7]  Y. Shan,et al.  Bilateral comparison between NMC and INRIM on microwave power sensor using type N and 3.5 mm connectors , 2010, CPEM 2010.

[8]  R. D. Moyer,et al.  Techniques for measuring the effective source reflection coefficient of two-resistor power splitters , 1987, IEEE Transactions on Instrumentation and Measurement.

[9]  Dieter Janik,et al.  An efficient broadband method for equivalent source reflection coefficient measurements , 2000, Conference on Precision Electromagnetic Measurements. Conference Digest. CPEM 2000 (Cat. No.00CH37031).

[10]  Ronald A. Ginley A Direct Comparison System for Measuring Radio Frequency Power (100 kHz to 18 GHz) , 2006 .

[11]  John R. Juroshek,et al.  A Direct Calibration Method for Measuring Equivalent Source Mismatch | NIST , 1997 .

[12]  K. Wong,et al.  Power sensor calibration and uncertainties , 2002, 60th ARFTG Conference Digest, Fall 2002..

[13]  A. Y. Rumfelt,et al.  Radio frequency power measurements , 1967 .

[14]  O.C. Lundstrom,et al.  Microwave Power Measurement , 1947, Proceedings of the IRE.

[15]  Klas Yhland,et al.  Measurement Uncertainty in Power Splitter Effective Source Match , 2007, IEEE Transactions on Instrumentation and Measurement.

[16]  Glenn F. Engen,et al.  Microwave Circuit Theory and Foundations of Microwave Metrology , 1992 .

[17]  M. Rodriguez Towards traceability of the direct calibration method to the cal kit standards , 2000, Conference on Precision Electromagnetic Measurements. Conference Digest. CPEM 2000 (Cat. No.00CH37031).

[18]  M J Salter,et al.  An approach to the treatment of uncertainty in complex S-parameter measurements , 2002 .

[19]  Yu Song Meng,et al.  Direct comparison transfer of microwave power sensor calibration with an adaptor : modeling and evaluation. , 2013 .

[20]  J.R. Juroshek NIST 0.05-50 GHz direct comparison power calibration system , 2000, Conference on Precision Electromagnetic Measurements. Conference Digest. CPEM 2000 (Cat. No.00CH37031).

[21]  Y. Shan,et al.  Development of a 50 GHz coaxial direct comparison transfer microwave power sensor calibration system at NMC , 2010, CPEM 2010.

[22]  Y. Shan,et al.  Direct comparison transfer microwave power sensor calibration system , 2008, 2008 Conference on Precision Electromagnetic Measurements Digest.