A comprehensive experimental characterization of the iPIX gamma imager

The results of more than 280 different experiments aimed at exploring the main features and performances of a newly developed gamma imager, called iPIX, are summarized in this paper. iPIX is designed to quickly localize radioactive sources while estimating the ambient dose equivalent rate at the measurement point. It integrates a 1 mm thick CdTe detector directly bump-bonded to a Timepix chip, a tungsten coded-aperture mask, and a mini RGB camera. It also represents a major technological breakthrough in terms of lightness, compactness, usability, response sensitivity, and angular resolution. As an example of its key strengths, an 241Am source with a dose rate of only few nSv/h can be localized in less than one minute.

[1]  F. Laine,et al.  CARTOGAM – a portable gamma camera for remote localisation of radioactive sources in nuclear facilities , 2001 .

[2]  E E Fenimore,et al.  New family of binary arrays for coded aperture imaging. , 1989, Applied optics.

[3]  Zhong He,et al.  The Polaris-H imaging spectrometer , 2015 .

[4]  Daniel Turecek,et al.  Pixelman: a multi-platform data acquisition and processing software package for Medipix2, Timepix and Medipix3 detectors , 2011 .

[5]  Rafael Ballabriga,et al.  Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements , 2007 .

[6]  H. Anger,et al.  Use of a Gamma-Ray Pinhole Camera for in vivo Studies , 1952, Nature.

[7]  A new mask-antimask coded-aperture telescope for hard X-ray astronomy , 1991 .

[8]  Mathieu Thevenin,et al.  GAMPIX: A new generation of gamma camera , 2012, Proceedings of the 2012 Conference on Design and Architectures for Signal and Image Processing.

[9]  D. Esperante,et al.  The Timepix Telescope for high performance particle tracking , 2013, 1304.5175.

[10]  C. Mahe,et al.  Development of a portable gamma camera with coded aperture , 2006 .

[11]  D. J. Brenner Conversion Coefficients for Use in Radiological Protection against External Radiation , 1999 .

[12]  Wolfgang Raskob,et al.  BOOSTER: Development of a toolbox for triage of large group of individuals exposed to radioactive material , 2013, 2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (ANIMMA).

[13]  Thierry Varet,et al.  Evaluation of the next generation gamma imager , 2013, 2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (ANIMMA).

[14]  J. Atteia,et al.  Gamma-Ray Bursts , 2009 .

[15]  R. Dicke SCATTER-HOLE CAMERAS FOR X-RAYS AND GAMMA RAYS. , 1968 .

[16]  J. Bouchami,et al.  Performance of the Medipix and Timepix devices for the recognition of electron-gamma radiation fields , 2011 .