Sub-electron readout noise in a Skipper CCD fabricated on high resistivity silicon

The readout noise for Charge-Coupled Devices (CCDs) has been the main limitation when using these detectors for measuring small amplitude signals. A scientific CCD fabricated on a high-resistivity silicon substrate utilizing a floating gate amplifier with the capability of multiple sampling of the charge signal is described in this paper. The Skipper CCD architecture and its advantages for low noise applications are discussed. A technique for obtaining sub-electron readout noise levels is presented, and its noise and signal characteristics are derived. We demonstrate that with this procedure a very low readout noise of 0.2e −  RMS can be achieved. The contribution of other noise sources (output stage, vertical and horizontal charge transfer inefficiency, and dark current noise) are also considered. The optimum number of samples for achieving the total lowest possible noise level is obtained. This technique is applied to an X-rays experiment using a 55Fe source.

[1]  I. McLean,et al.  Ground-based and Airborne Instrumentation for Astronomy , 2006 .

[2]  G. Smith,et al.  Nobel Lecture: The invention and early history of the CCD , 2010 .

[3]  H. Cease,et al.  CCD testing and characterization for dark energy survey , 2006, SPIE Astronomical Telescopes + Instrumentation.

[4]  James R. Janesick,et al.  Sub-electron noise charge-coupled devices , 1990, Other Conferences.

[5]  K. Kandiah,et al.  Limits of resolution of charge sensitive detector systems , 1993 .

[6]  D. DePoy,et al.  Focal plane detectors for Dark Energy Camera (DECam) , 2010, Astronomical Telescopes + Instrumentation.

[7]  I. McLean Electronic imaging in astronomy : detectors and instrumentation , 1997 .

[8]  The Dark Energy Camera (DECam) A new instrument for the Dark Energy Survey , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[9]  Mingzhi Wei,et al.  Fully depleted, back-illuminated charge-coupled devices fabricated on high-resistivity silicon , 2003 .

[10]  Prospects for a direct dark matter search using high resistivity CCD detectors , 2008, 0802.2872.

[11]  B. Flaugher The Dark Energy Survey instrument design , 2006, SPIE Astronomical Telescopes + Instrumentation.

[12]  H. Wey,et al.  An improved correlated double sampling circuit for low noise charge coupled devices , 1990 .

[13]  Willard S. Boyle Nobel Lecture: CCD—An extension of man’s view , 2010 .

[14]  D. D. Wen,et al.  Design and operation of a floating gate amplifier , 1974 .

[15]  James E. Gunn,et al.  New advancements in charge-coupled device technology: subelectron noise and 4096 x 4096 pixel CCDs , 1990, Other Conferences.

[16]  J. Janesick,et al.  Scientific Charge-Coupled Devices , 2001 .

[17]  B. Kilminster,et al.  Direct search for low mass dark matter particles with CCDs , 2011, 1105.5191.

[18]  Walter Stuermer,et al.  Characterization of DECam focal plane detectors , 2008, Astronomical Telescopes + Instrumentation.

[19]  Alan Owens,et al.  On the experimental determination of the Fano factor in Si at soft X-ray wavelengths , 2002 .

[20]  J. Hynecek Low-noise and high-speed charge detection in high-resolution CCD image sensors , 1997 .

[21]  Barry E. Burke,et al.  Fano-Noise-Limited CCDs , 1988, Optics & Photonics.

[22]  Alan A. Wells,et al.  The X-ray energy response of silicon Part A. Theory , 1994 .