Condition monitoring of bones using piezo-transducers
暂无分享,去创建一个
[1] M Fitzmaurice,et al. The Use of Biomedical Sensors to Monitor Capsule Formation Around Soft Tissue Implants , 2006, Annals of Plastic Surgery.
[2] Takashi Sakai,et al. Biochemical compatibility of PZT piezoelectric ceramics covered with titanium thin film , 2006 .
[3] T. Ikeda. Fundamentals of piezoelectricity , 1990 .
[4] R Guidoin,et al. Polyvinylidene fluoride (PVDF) as a biomaterial: from polymeric raw material to monofilament vascular suture. , 1995, Journal of biomedical materials research.
[5] T. Keaveny,et al. Evolution of the biomechanical material properties of the femur , 2002, The Anatomical record.
[6] Suresh Bhalla,et al. Calibration of piezo-impedance transducers for strength prediction and damage assessment of concrete , 2005 .
[7] Suresh Bhalla,et al. A mechanical impedance approach for structural identification, health monitoring and non-destructive evaluation using piezo-impedance transducers. , 2004 .
[8] Victor Giurgiutiu,et al. Embedded Self-Sensing Piezoelectric Active Sensors for On-Line Structural Identification , 2002 .
[9] Suresh Bhalla,et al. Bone Characterization using Piezotransducers as Biomedical Sensors , 2008 .
[10] Balkrishna S. Annigeri,et al. Structural Health Monitoring With Piezoelectric Active Sensors , 2001 .
[11] Charles R. Farrar,et al. Performance assessment and validation of piezoelectric active-sensors in structural health monitoring , 2006 .
[12] Suresh Bhalla,et al. Structural impedance based damage diagnosis by piezo‐transducers , 2003 .
[13] Suresh Bhalla,et al. Bone Characterization Using Piezo-Transducers as Bio-Medical Sensors , 2012 .
[14] Eiichi Fukada,et al. On the Piezoelectric Effect of Bone , 1957 .
[15] Joel W. Ager,et al. Fracture and Ageing in Bone: Toughness and Structural Characterization , 2006 .
[16] G. Kawiecki. Modal damping measurement for damage detection , 2001 .
[17] Suresh Bhalla,et al. Structural identification and damage diagnosis using self-sensing piezo-impedance transducers , 2006 .
[18] E Panagiotopoulos,et al. Evaluation of modal damping factor as a diagnostic tool for osteoporosis and its relation with serum osteocalcin and collagen I N-telopeptide for monitoring the efficacy of alendronate in ovariectomized rats. , 2006, Journal of pharmaceutical and biomedical analysis.
[19] Yaowen Yang,et al. Practical issues related to the application of the electromechanical impedance technique in the structural health monitoring of civil structures: I. Experiment , 2008 .
[20] M. Grant,et al. In vitro biocompatibility testing of polymers for orthopaedic implants using cultured fibroblasts and osteoblasts. , 1995, Biomaterials.
[21] Karl-Hans Laermann. Assessment of structural integrity and durability—a task of experimental mechanics , 2010 .
[22] C. Kao,et al. The biocompatibility evaluation of epoxy resin-based root canal sealers in vitro. , 2002, Biomaterials.
[23] Craig A. Rogers,et al. Coupled Electro-Mechanical Analysis of Adaptive Material Systems — Determination of the Actuator Power Consumption and System Energy Transfer , 1994 .
[24] K. Dodou,et al. Rheological studies on pressure-sensitive silicone adhesives and drug-in-adhesive layers as a means to characterise adhesive performance. , 2007, International journal of pharmaceutics.
[25] Daniel J. Inman,et al. IMPEDANCE-BASED HEALTH MONITORING OF CIVIL STRUCTURAL COMPONENTS , 2000 .
[26] Suresh Bhalla,et al. Performance of smart piezoceramic patches in health monitoring of a RC bridge , 2000 .
[27] Piervincenzo Rizzo,et al. Assessment of dental implant stability by means of the electromechanical impedance method , 2011 .
[28] Suresh Bhalla,et al. Ultra Low-cost Adaptations of Electro-mechanical Impedance Technique for Structural Health Monitoring , 2009 .
[29] C A Bassett,et al. Biologic significance of piezoelectricity , 1967, Calcified tissue research.