A facial wearable robot for supporting eye opening and closure movement

This study proposes a novel facial wearable robot for supporting eyelid movements. The robot is designed for people with facial paralysis, especially on one side of the face. People with facial paralysis are not able to blink, which leads to dry eyes and could cause permanent damage to the cornea. They are also prone to developing synkinesis during recovery, and a biofeedback-enabled rehabilitation is considered to prevent it. Based on these, we developed a robot system to support eyelid movements on the paralyzed side, based on the eye closure on the healthy side. The robot has a novel mechanism for supporting the eyelid control, made from soft material, which is called Eyelid Gating Mechanism (ELGM). ELGM deforms by simple rotational or linear actuation inputs and its deformation is customized to eyelid movements. Therefore, this robot can provide non-invasive and gentle support for eyelid movements. In this paper, we present the development and performance evaluation of the developed facial wearable robot.

[1]  C. Beurskens,et al.  Mime therapy improves facial symmetry in people with long-term facial nerve paresis: a randomised controlled trial. , 2006, The Australian journal of physiotherapy.

[2]  Xiaoxiao Li,et al.  The Proceeding of the Research on Human Exoskeleton , 2014 .

[3]  M. Aramideh,et al.  Eyelid movements: behavioral studies of blinking in humans under different stimulus conditions. , 2003, Journal of neurophysiology.

[4]  Paul Lukowicz,et al.  In the blink of an eye: combining head motion and eye blink frequency for activity recognition with Google Glass , 2014, AH.

[5]  Nigel H Lovell,et al.  Restoration of eye closure in facial paralysis using implantable electromagnetic actuator. , 2016, Journal of plastic, reconstructive & aesthetic surgery : JPRAS.

[6]  S. Kanoh,et al.  Development of an eyewear to measure eye and body movements , 2015, 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[7]  Restoration of Eyelid Closure in Facial Paralysis Using Artificial Muscle: Preliminary Cadaveric Analysis , 2008 .

[8]  Kenji Suzuki,et al.  A facial wearable robot with eyelid gating mechanism for supporting eye blink , 2016, 2016 International Symposium on Micro-NanoMechatronics and Human Science (MHS).

[9]  J. Finsterer Management of peripheral facial nerve palsy , 2008, European Archives of Oto-Rhino-Laryngology.

[10]  Yasuhisa Hasegawa,et al.  Intention-based walking support for paraplegia patients with Robot Suit HAL , 2007, Adv. Robotics.

[11]  Norihisa Miki,et al.  Wearable line-of-sight detection system using micro-fabricated transparent optical sensors on eyeglasses , 2014 .

[12]  Roger Stevens,et al.  Gray's Anatomy for Students. , 2015 .

[13]  A. Wong-Foy,et al.  Force requirements for artificial muscle to create an eyelid blink with eyelid sling. , 2010, Archives of facial plastic surgery.

[14]  James T Heaton,et al.  Infrared-based blink-detecting glasses for facial pacing: toward a bionic blink. , 2014, JAMA facial plastic surgery.

[15]  Kenji Suzuki,et al.  Robot Assisted Physiotherapy to Support Rehabilitation of Facial Paralysis , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[16]  N. Takeda,et al.  Biofeedback Rehabilitation for Prevention of Synkinesis after Facial Palsy , 2003 .

[17]  I G Williamson,et al.  The clinical problem of Bell's palsy: is treatment with steroids effective? , 1996, The British journal of general practice : the journal of the Royal College of General Practitioners.

[18]  N. Shimizu [Neurology of eye movements]. , 2000, Rinsho shinkeigaku = Clinical neurology.