Multiple laboratory comparison of the doubly labeled water technique.

A double-blind study was conducted to determine between-laboratory variability in the doubly labeled water method for measurement of total energy expenditure in humans, and to compare the accuracy and precision of three widely-used procedures for calculating rates of carbon dioxide production from the original isotope data. Eighteen laboratories from five countries participated in the study. All laboratories were provided with five water standards containing varying amounts of 2H and 18O, and in addition 11 laboratories were provided with urine and dose specimens from one (six laboratories) or two (five laboratories) healthy elderly subjects of normal height and weight undergoing a calorimetric validation of the doubly labeled water method. The data from the five water standards were analyzed to predict between-laboratory variability in the doubly labeled water technique in all laboratories. In addition, data from the subjects were analyzed using the "slope-intercept", "2-point" and "modified" methods of calculation. The results confirm that the doubly labeled water method can be an accurate technique for the measurement of energy expenditure in adult human subjects in some laboratories. However, there was substantial between-laboratory variability in the results and some laboratories returned physiologically impossible results. There was no significant effect of calculation procedure on the accuracy of the technique in this limited comparison, although the slope-intercept procedure appeared to be more susceptible to analytical error than the other procedures. The isotope standards analyzed by participants in this study will be made available to other investigators on request.

[1]  G. Dallal,et al.  DLW: a computer program for the calculation of total energy expenditure in doubly labeled water (2H218O) studies. , 1991, Computers and biomedical research, an international journal.

[2]  W. Coward,et al.  Comparison of the doubly labeled water (2H2(18)O) method with indirect calorimetry and a nutrient-balance study for simultaneous determination of energy expenditure, water intake, and metabolizable energy intake in preterm infants. , 1986, The American journal of clinical nutrition.

[3]  M. Fiatarone,et al.  What are the dietary energy needs of elderly adults? , 1992, International journal of obesity and related metabolic disorders : journal of the International Association for the Study of Obesity.

[4]  S. Roberts,et al.  Use of the doubly labeled water method for measurement of energy expenditure, total body water, water intake, and metabolizable energy intake in humans and small animals. , 1989, Canadian journal of physiology and pharmacology.

[5]  E. Jéquier,et al.  Assessment of energy expenditure and fuel utilization in man. , 1987, Annual review of nutrition.

[6]  W. Rumpler,et al.  Comparison of doubly labeled water, intake-balance, and direct- and indirect-calorimetry methods for measuring energy expenditure in adult men. , 1990, The American journal of clinical nutrition.

[7]  D. Schoeller,et al.  Five-day comparison of the doubly labeled water method with respiratory gas exchange. , 1984, The American journal of clinical nutrition.

[8]  K R Westerterp,et al.  Comparison of doubly labeled water with respirometry at low- and high-activity levels. , 1988, Journal of applied physiology.

[9]  David G. Schlundt,et al.  Nutrient balance in humans: effects of diet composition. , 1991, The American journal of clinical nutrition.

[10]  D A Schoeller,et al.  Measurement of energy expenditure in humans by doubly labeled water method. , 1982, Journal of applied physiology: respiratory, environmental and exercise physiology.

[11]  A. Miller,et al.  Precise measurement of total body water using trace quantities of deuterium oxide. , 1977, Biomedical mass spectrometry.

[12]  D A Schoeller,et al.  Measurement of energy expenditure in free-living humans by using doubly labeled water. , 1988, The Journal of nutrition.