The Trade-off between Solar Reflectance and Above-Sheathing Ventilation for Metal Roofs on Residential and Commercial Buildings

An alternative to white and cool-color roofs that meets prescriptive requirements for steep-slope (residential and non-residential) and low-slope (non-residential) roofing has been documented. Roofs fitted with an inclined air space above the sheathing (herein termed above-sheathing ventilation, or ASV), performed as well as if not better than high-reflectance, high-emittance roofs fastened directly to the deck. Field measurements demonstrated the benefit of roofs designed with ASV. A computer tool was benchmarked against the field data. Testing and benchmarks were conducted at roofs inclined at 18.34 ; the roof span from soffit to ridge was 18.7 ft (5.7 m). The tool was then exercised to compute the solar reflectance needed by a roof equipped with ASV to exhibit the same annual cooling load as that for a direct-to-deck cool-color roof. A painted metal roof with an air space height of 0.75 in. (0.019 m) and spanning 18.7 ft (5.7 m) up the roof incline of 18.34 needed only a 0.10 solar reflectance to exhibit the same annual cooling load as a direct-to-deck cool-color metal roof (solar reflectance of 0.25). This held for all eight ASHRAE climate zones complying with ASHRAE 90.1 (2007a). A dark heat-absorbing roof fitted with 1.5 in. (0.038 m)more » air space spanning 18.7 ft (5.7 m) and inclined at 18.34 was shown to have a seasonal cooling load equivalent to that of a conventional direct-to-deck cool-color metal roof. Computations for retrofit application based on ASHRAE 90.1 (1980) showed that ASV air spaces of either 0.75 or 1.5 in. (0.019 and 0.038 m) would permit black roofs to have annual cooling loads equivalent to the direct-to-deck cool roof. Results are encouraging, and a parametric study of roof slope and ASV aspect ratio is needed for developing guidelines applicable to all steep- and low-slope roof applications.« less

[1]  Majid Keyhani,et al.  Natural Convection Heat Transfer in Roofs with Above-Sheathing Ventilation , 2007 .

[2]  William A Miller The Effects of Infrared-Blocking Pigments and Deck Venting on Stone-Coated Metal Residential Roofs , 2006 .

[3]  T. Unny,et al.  Free convective heat transfer across inclined air layers , 1976 .

[4]  D. Edwards,et al.  Experimental Investigation of Natural Convection in Inclined Rectangular Regions of Differing Aspect Ratios , 1976 .

[5]  J. B. Cummings,et al.  Duct Leakage Impacts on Airtightness, Infiltration, and Peak Electrical Demand in Florida Homes , 1990 .

[6]  William A. Miller,et al.  TASK 2.5.5 NATURAL EXPOSURE TESTING IN CALIFORNIA , 2010 .

[7]  Guk-Rwang Won American Society for Testing and Materials , 1987 .

[8]  T. W. Petrie,et al.  Comparison of Techniques for In Situ Nondamaging Measurement of Solar Reflectances of Low-Slope Roof Membranes , 2001 .

[9]  K. E. Wilkes Thermal model of attic systems with radiant barriers , 1991 .

[10]  B. J. Brinkworth,et al.  A procedure for the routine calculation of laminar free and mixed convection in inclined ducts , 2000 .

[11]  William A. Miller,et al.  Next-Generation Roofs and Attics for Homes , 2008 .

[12]  H. Akbari,et al.  Evolution of cool-roof standards in the United States , 2008 .

[13]  Danny S. Parker,et al.  Comparative Summer Attic Thermal Performance of Six Roof Constructions , 1998 .

[14]  Danny S. Parker,et al.  Comparative Evaluation of the Impact of Roofing Systems on Residential Cooling Energy Demand in Florida , 2002 .

[15]  T. G. Kollie,et al.  Evaluation of a commercial, portable, ambient‐temperature emissometer , 1990 .

[16]  Ronnen Levinson,et al.  Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements - eScholarship , 2002 .

[17]  H. Akbari,et al.  Weathering of Roofing Materials-An Overview , 2008 .

[18]  Vice President,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. , 2007 .

[19]  Frederick G. Hammitt,et al.  Proceedings of the 1966 Heat Transfer and Fluid Mechanics Institute , 1967 .

[20]  Thomas W. Petrie,et al.  Comparison of Cathedralized Attics to Conventional Attics : Where and When Do Cathedralized Attics Save Energy and Operating Costs ? , 1995 .

[21]  H. Akbari,et al.  Methods of creating solar-reflective nonwhite surfaces and their application to residential roofing materials , 2005 .

[22]  Jeffrey E. Christian,et al.  Effect of radiant barriers and attic ventilation on residential attics and attic duct systems: New tools for measuring and modeling , 1998 .

[23]  J. Wilson,et al.  THE IMPACT OF ABOVE-SHEATHING VENTILATION ON THE THERMAL AND MOISTURE PERFORMANCE OF STEEP-SLOPE RESIDENTIAL ROOFS AND ATTICS , 2006 .

[24]  Ephraim M Sparrow,et al.  Natural Convection in Open-Ended Inclined Channels , 1985 .