Enhancement in sample collection for the detection of MDMA using a novel planar SPME (PSPME) device coupled to ion mobility spectrometry (IMS).

Trace detection of illicit drugs challenges the scientific community to develop improved sensitivity and selectivity in sampling and detection techniques. Ion mobility spectrometry (IMS) is one of the prominent trace detectors for illicit drugs and explosives, mostly due to its portability, high sensitivity and fast analysis. Current sampling methods for IMS rely on wiping suspected surfaces or withdrawing air through filters to collect particulates. These methods depend greatly on the particulates being bound onto surfaces or having sufficient vapour pressure to be airborne. Many of these compounds are not readily available in the headspace due to their low vapour pressure. This research presents a novel SPME device for enhanced air sampling and shows the use of optimized IMS by genetic algorithms to target volatile markers and/or odour signatures of illicit substances. The sampling method was based on unique static samplers, planar substrates coated with sol-gel polydimethyl siloxane (PDMS) nanoparticles, also known as planar solid-phase microextraction (PSPME). Due to its surface chemistry, high surface area and capacity, PSPME provides significant increases in sensitivity over conventional fibre SPME. The results show a 50-400 times increase in the detection capacity for piperonal, the odour signature of 3,4-methylenedioxymethamphetamine (MDMA). The PSPME-IMS technique was able to detect 600 ng of piperonal in a 30 s extraction from a quart-sized can containing 5 MDMA tablets, while detection using fibre SPME-IMS was not attainable. In a blind study of six cases suspected to contain varying amounts of MDMA in the tablets, PSPME-IMS successfully detected five positive cases and also produced no false positives or false negatives. One positive case had minimal amounts of MDMA resulting in a false negative response for fibre SPME-IMS.

[1]  M. Yonamine,et al.  Detection of cocaine and cocaethylene in sweat by solid-phase microextraction and gas chromatography/mass spectrometry. , 2004, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[2]  K. Furton,et al.  Identification of odor signature chemicals in cocaine using solid-phase microextraction-gas chromatography and detector-dog response to isolated compounds spiked on U.S. paper currency. , 2002, Journal of chromatographic science.

[3]  C. Koester,et al.  Optimum methamphetamine profiling with sample preparation by solid-phase microextraction. , 2002, Journal of forensic sciences.

[4]  J. Pawliszyn,et al.  Solid phase microextraction with thermal desorption using fused silica optical fibers , 1990 .

[5]  J R Almirall,et al.  Application of solid-phase microextraction to the recovery of explosives and ignitable liquid residues from forensic specimens. , 2000, Journal of chromatography. A.

[6]  M. Chiarotti,et al.  Simultaneous detection of some drugs of abuse in saliva samples by SPME technique. , 2003, Forensic science international.

[7]  Hanh Lai,et al.  Analysis of the volatile chemical markers of explosives using novel solid phase microextraction coupled to ion mobility spectrometry. , 2008, Journal of separation science.

[8]  F. Musshoff,et al.  Fully automated determination of amphetamines and synthetic designer drugs in hair samples using headspace solid-phase microextraction and gas chromatography-mass spectrometry. , 2002, Journal of Chromatographic Science.

[9]  M. Yonamine,et al.  Headspace solid-phase microextraction of cannabinoids in human head hair samples. , 2007, Journal of separation science.

[10]  A. Parrott Is ecstasy MDMA? A review of the proportion of ecstasy tablets containing MDMA, their dosage levels, and the changing perceptions of purity , 2004, Psychopharmacology.

[11]  W. Bertsch,et al.  A Comprehensive Sample Preparation Scheme for Accelerants in Suspect Arson Cases , 1999 .

[12]  Maurice Marshall,et al.  Aspects of Explosives Detection , 2011 .

[13]  Hanh Lai,et al.  Headspace sampling and detection of cocaine, MDMA, and marijuana via volatile markers in the presence of potential interferences by solid phase microextraction–ion mobility spectrometry (SPME-IMS) , 2008, Analytical and bioanalytical chemistry.

[14]  Z. Karpas,et al.  Ion mobility spectrometry , 1993, Breathborne Biomarkers and the Human Volatilome.

[15]  M. Yonamine,et al.  Solid-phase micro-extraction-gas chromatography-mass spectrometry and headspace-gas chromatography of tetrahydrocannabinol, amphetamine, methamphetamine, cocaine and ethanol in saliva samples. , 2003, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[16]  Kenneth G Furton,et al.  Solid phase microextraction ion mobility spectrometer interface for explosive and taggant detection. , 2005, Journal of separation science.

[17]  F. Musshoff,et al.  Fully automated determination of cannabinoids in hair samples using headspace solid-phase microextraction and gas chromatography-mass spectrometry. , 2002, Journal of analytical toxicology.

[18]  Kenneth G. Furton,et al.  Laboratory and field experiments used to identify Canis lupus var. familiaris active odor signature chemicals from drugs, explosives, and humans , 2003, Analytical and bioanalytical chemistry.

[19]  Gary A. Eiceman,et al.  Chemical class information in ion mobility spectra at low and elevated temperatures , 2001 .

[20]  Monica Joshi,et al.  Analysis of volatile components of drugs and explosives by solid phase microextraction-ion mobility spectrometry. , 2008, Journal of separation science.