Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose.

Tear glucose sensing for diabetes management has long been sought as an alternative to more invasive self-monitoring of blood glucose (SMBG). However, tear glucose sensors were known to have limitations, including correlation issues with blood glucose due to low sample volume, low concentration of glucose in the tear fluid, and evaporation of the tear sample. An engineering design approach to solve these problems led to the development of an integrated device capable of collecting the tear sample from the ocular surface with little to no stress on the eye, with an extremely low limit of detection, broad dynamic range, and rapid detection and analysis of sample. Here we present the development of a prototypical self-monitoring of tear glucose (SMTG) sensor, summarizing bench studies on the enzymes and their specificity, the development of the fluid capture device and its manufacture and performance and results of system testing in an animal study where safety, lag time and tear glucose to blood glucose correlation were assessed.

[1]  Jeffrey T La Belle,et al.  A Disposable Tear Glucose Biosensor—Part 4 , 2014, Journal of diabetes science and technology.

[2]  L. C. Clark,et al.  ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY , 1962 .

[3]  G. Fulop,et al.  Tear urea nitrogen and creatinine levels in renal patients , 1988, Acta ophthalmologica.

[4]  Carlos Eduardo Ferrante do Amaral,et al.  Current development in non-invasive glucose monitoring. , 2008, Medical engineering & physics.

[5]  Igarashi,et al.  Increasing the thermal stability of the water-soluble pyrroloquinoline quinone glucose dehydrogenase by single amino acid replacement. , 2000, Enzyme and microbial technology.

[6]  Justin T. Baca,et al.  Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus. , 2007, The ocular surface.

[7]  A Disposable Tear Glucose Biosensor—Part 1: Design and Concept Testing , 2010, Journal of diabetes science and technology.

[8]  A. Turner,et al.  Glucose oxidase: an ideal enzyme , 1992 .

[9]  Yu-Te Liao,et al.  A 3-$\mu\hbox{W}$ CMOS Glucose Sensor for Wireless Contact-Lens Tear Glucose Monitoring , 2012, IEEE Journal of Solid-State Circuits.

[10]  G. Santhosh Kumar,et al.  Substrate specificity of glucose dehydrogenase (GDH) of Enterobacter asburiae PSI3 and rock phosphate solubilization with GDH substrates as C sources. , 2005, Canadian journal of microbiology.

[11]  Eun-Hyung Yoo,et al.  Glucose Biosensors: An Overview of Use in Clinical Practice , 2010, Sensors.

[12]  Koji Sode,et al.  Cloning and functional expression of glucose dehydrogenase complex of Burkholderia cepacia in Escherichia coli. , 2006, Journal of biotechnology.

[13]  Dharmendra R. Patel,et al.  A Disposable Tear Glucose Biosensor—Part 2: System Integration and Model Validation , 2010, Journal of diabetes science and technology.

[14]  S. McGuire,et al.  Centers for Disease Control and Prevention. State indicator report on Physical Activity, 2014. Atlanta, GA: U.S. Department of Health and Human Services; 2014. , 2014, Advances in nutrition.

[15]  Wenzhao Jia,et al.  Tattoo-based noninvasive glucose monitoring: a proof-of-concept study. , 2015, Analytical chemistry.

[16]  Josef Batík METHODISCHE BEMERKUNG ZUR BIOCHEMISCHEN TRÄNENUNTERSUCHUNG , 1965 .

[17]  N. J. Van Haeringen,et al.  Clinical biochemistry of tears , 1981 .

[18]  Justin T. Baca,et al.  Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers. , 2007, Clinical chemistry.

[19]  Jeffrey T La Belle,et al.  A Disposable Tear Glucose Biosensor—Part 3: Assessment of Enzymatic Specificity , 2011, Journal of diabetes science and technology.

[20]  J. Ellison,et al.  Review of Adverse Events Associated With False Glucose Readings Measured by GDH-PQQ–Based Glucose Test Strips in the Presence of Interfering Sugars , 2010, Diabetes Care.

[21]  D. Zoukhri Effect of inflammation on lacrimal gland function. , 2006, Experimental eye research.

[22]  H Salem,et al.  Riot control agents: pharmacology, toxicology, biochemistry and chemistry , 2001, Journal of applied toxicology : JAT.

[23]  Lutz Heinemann,et al.  Finger Pricking and Pain: A Never Ending Story , 2008, Journal of diabetes science and technology.

[24]  N. J. van Haeringen,et al.  Collection method dependant concentrations of some metabolites in human tear fluid, with special reference to glucose in hyperglycaemic conditions , 1977, Albrecht von Graefes Archiv für klinische und experimentelle Ophthalmologie.

[25]  A. Olokoba,et al.  Type 2 diabetes mellitus: a review of current trends. , 2012, Oman medical journal.

[26]  Koji Sode,et al.  Direct electron transfer type disposable sensor strip for glucose sensing employing an engineered FAD glucose dehydrogenase. , 2013, Enzyme and microbial technology.

[27]  Santhisagar Vaddiraju,et al.  Technologies for Continuous Glucose Monitoring: Current Problems and Future Promises , 2010, Journal of diabetes science and technology.

[28]  G J Kost,et al.  Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing , 2001, Critical care medicine.

[29]  R. Sack,et al.  Tear Glucose Dynamics in Diabetes Mellitus , 2006, Current eye research.

[30]  R M Hill,et al.  Human tear glucose. , 1982, Investigative ophthalmology & visual science.

[31]  Sang-Hoon Lee,et al.  A capacitive, biocompatible and adhesive electrode for long-term and cap-free monitoring of EEG signals. , 2013, Journal of neural engineering.

[32]  Adam Heller,et al.  Electrochemical glucose sensors and their applications in diabetes management. , 2008, Chemical reviews.

[33]  Hiroyuki Kudo,et al.  A flexible and wearable glucose sensor based on functional polymers with soft-MEMS techniques. , 2006, Biosensors & bioelectronics.

[34]  C. Ng,et al.  Barriers and facilitators to self-monitoring of blood glucose in people with type 2 diabetes using insulin: a qualitative study , 2014, Patient preference and adherence.

[35]  Motowo Nakajima,et al.  Modified substrate specificity of pyrroloquinoline quinone glucose dehydrogenase by biased mutation assembling with optimized amino acid substitution , 2006, Applied Microbiology and Biotechnology.

[36]  K. Sode,et al.  Review of Glucose Oxidases and Glucose Dehydrogenases: A Bird's Eye View of Glucose Sensing Enzymes , 2011, Journal of diabetes science and technology.

[37]  Huanfen Yao,et al.  A contact lens with embedded sensor for monitoring tear glucose level. , 2011, Biosensors & bioelectronics.

[38]  L. B. E. A. Hoeks,et al.  Real‐time continuous glucose monitoring system for treatment of diabetes: a systematic review , 2011, Diabetic medicine : a journal of the British Diabetic Association.

[39]  M. V. von Herrath,et al.  Type 1 diabetes: etiology, immunology, and therapeutic strategies. , 2011, Physiological reviews.