Immunosensor for the Determination of Okadaic Acid Based on Screen-Printed Electrode

A disposable immunosensor for okadaic acid (OA), using a screen-printed electrode (SPE), was developed and characterised. Detection of the product, p-aminophenol, resulting from the reaction catalysed by alkaline phosphatase (AP), was carried out using an amperometric three-electrode system poised at a voltage of + 300 mV versus Ag/AgCl. Alkaline phosphatase was used as a label for the antigen, OA, and two kinds of alkaline phosphatase preparation were studied for the conjugation of okadaic acid. The calibration curve for okadaic acid obtained from the conjugate created from low-activity AP, 969 units/mg, was unsatisfactory in terms of sensitivity, but a high-activity conjugate delivered the required sensitivity and limit of detection. Studies on the stability of the sensor with α-OA antibody and OA-AP conjugate showed that the current response decreased drastically after one day. Stabilisation strategies have been formulated to overcome this problem. The calibration curve obtained with the high activity conjugate was linear up to 40 ng/ml of okadaic acid with a minimum concentration of analyte detected of 5 ng/ml and a detection limit of 2 ng/ml.

[1]  G. Guilbault,et al.  Development of an amperometric l-ascorbic acid (Vitamin C) sensor based on electropolymerised aniline for pharmaceutical and food analysis , 2001 .

[2]  Jean-Louis Marty,et al.  Disposable cholinesterase biosensor for the detection of pesticides in water-miscible organic solvents , 2001 .

[3]  Giovanna Marrazza,et al.  Electrochemical DNA biosensor for environmental monitoring , 2001 .

[4]  M. Hennion,et al.  Immunoaffinity extraction as a new approach for an improved liquid chromatography-mass spectrometric or fluorimetric determination of okadaic acid in shellfish and algae , 2000 .

[5]  P. Vale,et al.  Comparison between HPLC and a commercial immunoassay kit for detection of okadaic acid and esters in Portuguese bivalves. , 1999, Toxicon : official journal of the International Society on Toxinology.

[6]  Christophe A. Marquette,et al.  Semi-automated membrane based chemiluminescent immunosensor for flow injection analysis of okadaic acid in mussels , 1999 .

[7]  G. Guilbault,et al.  Development of an ultrasensitive immunoassay for rapid measurement of okadaic acid and its isomers. , 1999, Analytical chemistry.

[8]  U. Bilitewski,et al.  Investigations with respect to stabilization of screen-printed enzyme electrodes , 1999 .

[9]  J. Pingarrón,et al.  Graphite-Teflon composite bienzyme electrodes for the determination of L-lactate: application to food samples. , 1999, Biosensors & bioelectronics.

[10]  B. Danielsson,et al.  Polyethyleneimine-coated reticulated vitreous carbon electrode with immobilized enzymes as a substrate detector , 1998 .

[11]  G. Volpe,et al.  Amperometric detection of uric acid and hypoxanthine with Xanthine oxidase immobilized and carbon based screen-printed electrode. Application for fish freshness determination. , 1997, Talanta.

[12]  J. Crowther ELISA. Theory and practice. , 1995, Methods in molecular biology.

[13]  K. Alberti,et al.  The Diabetes Annual , 1993 .

[14]  R. Lathe Phd by thesis , 1988, Nature.

[15]  J. Pingarrón,et al.  Development of a bienzymic graphite–Teflon composite electrode for the determination of hypoxanthine in fish , 1998 .

[16]  G. Hermanson Homobifunctional Cross-linkers , 1996 .

[17]  John P. Hart,et al.  Development of a disposable amperometric sensor for reduced nicotinamide adenine dinucleotide based on a chemically modified screen-printed carbon electrode , 1994 .

[18]  E. Boyland,et al.  947. The oxidation of aromatic amines. Part V. Oxidation by perphosphoric acids , 1957 .