Multiple reaction monitoring as a method for identifying protein posttranslational modifications.

The activity of many transcriptional regulators is significantly altered by posttranslational modifications of specific sites. For example, the activity of the muscle-restricted transcription factor family myocyte enhancer factor 2 (MEF2) is tightly controlled by phosphorylation. This modification is responsible for either an increase or a decrease in transcriptional activity, depending on the specific amino acid residues that are phosphorylated by signal-dependent kinases. Although mass spectrometry-based methods, such as precursor ion and neutral loss scans, are extremely useful for identifying unknown phosphopeptides from a complex mixture, they do not take advantage of any prior knowledge about the protein being investigated. Quite often a significant amount of information is available. This may include the primary sequence, type of phosphorylation (serine/threonine vs. tyrosine), or predicted phosphoacceptor sites (consensus peptide that is targeted by a kinase). This information can be used to predict precursor and fragment ion m/z values for a multiple reaction monitoring (MRM) experiment. By using these highly sensitive MRM experiments to trigger dependent product ion scans on a hybrid quadrupole linear ion-trap instrument, we were able to identify low levels of phosphorylation of MEF2A (a member of the MEF2 family), and alpha-casein. This method of monitoring protein phosphorylation at specific phosphoacceptor sites may prove useful in understanding the physiological regulation of protein function.

[1]  Jack D. Henion,et al.  Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometry , 1987 .

[2]  E. Olson,et al.  Phosphorylation of the MADS-Box Transcription Factor MEF2C Enhances Its DNA Binding Activity* , 1996, The Journal of Biological Chemistry.

[3]  F. Beaudry,et al.  In vivo pharmacokinetic screening in cassette dosing experiments; the use of on-line Pprospekt liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry technology in drug discovery. , 1998, Rapid communications in mass spectrometry : RCM.

[4]  B. Thomson,et al.  Analytical performance of a high-pressure radio frequency-only quadrupole collision cell with an axial field applied by using conical rods , 1998 .

[5]  Jiahuai Han,et al.  Regulation of the MEF2 Family of Transcription Factors by p38 , 1999, Molecular and Cellular Biology.

[6]  B. Séraphin,et al.  A generic protein purification method for protein complex characterization and proteome exploration , 1999, Nature Biotechnology.

[7]  E. Olson,et al.  MEF2: a transcriptional target for signaling pathways controlling skeletal muscle growth and differentiation. , 1999, Current opinion in cell biology.

[8]  S. Carr,et al.  Mapping phosphorylation sites in proteins by mass spectrometry. , 2002, Methods in enzymology.

[9]  James W. Hager,et al.  A new linear ion trap mass spectrometer , 2002 .

[10]  Hanno Steen,et al.  Analysis of protein phosphorylation using mass spectrometry: deciphering the phosphoproteome. , 2002, Trends in biotechnology.

[11]  J C McDermott,et al.  Tandem affinity purification of protein complexes from mammalian cells. , 2002, BioTechniques.

[12]  J. Lill,et al.  Proteomic tools for quantitation by mass spectrometry. , 2003, Mass spectrometry reviews.

[13]  J. Hager,et al.  Product ion scanning using a Q-q-Q linear ion trap (Q TRAP) mass spectrometer. , 2003, Rapid communications in mass spectrometry : RCM.

[14]  G. Impey,et al.  Impurity and Degradation Product Analysis: High Sensitivity Qualitative & Quantitative Analysis Using a Hybrid Triple-Quadrupole-Linear Ion Trap Mass Spectrometer , 2003 .

[15]  M. Mårback,et al.  Phosphorylation Motifs Regulating the Stability and Function of Myocyte Enhancer Factor 2A* , 2003, The Journal of Biological Chemistry.