A semianalytic model to investigate the potential applications of x-ray scatter imaging.

Although x-ray scatter is generally regarded as a nuisance that reduces radiographic contrast (C) and the signal-to-noise ratio (SNR) in conventional images, many technologies have been devised to extract useful information from the scattered x rays. A systematic approach, however, for analyzing the potential applications of x-ray scatter imaging has been lacking. Therefore, we have formulated a simple but useful semianalytic model to investigate C and SNR in scatter images. Our model considers the imaging of a target object against a background material of the same dimensions when both are situated within a water phantom. We have selected biological materials (liver, fat, bone, muscle, blood, and brain matter) for which intermolecular form factors for coherent scattering were available. Analytic relationships between C and SNR were derived, and evaluated numerically as the target object thickness (0.01-40 mm) and photon energy (10-200 keV) were systematically varied. The fundamental limits of scatter imaging were assessed via calculations that assumed that all first-order scatter exiting the phantom, over 4 pi steradians, formed the signal. Calculations for a restricted detector solid angle were then performed. For the task of imaging white brain matter versus blood in a 15 cm thick water phantom, the maximum SNR, over all energies, for images based on the detection of all forward scatter within the angular range 2 degrees-12 degrees is greater than that of primary images for target object thicknesses < or = 23 mm. Use of the backscattered x rays within the range 158 degrees-178 degrees to image objects 3 cm below the surface of a 25 cm thick water phantom allows the liver to be distinguished from fat with a SNR superior to that of primary imaging when the objects are < or = 22 mm thick. Our analysis confirms the usefulness of scattered x rays, and provides simple methods for determining the regimes of medical interest in which x-ray scatter imaging could outperform conventional imaging.

[1]  E. Alhava,et al.  A coherent/Compton scattering method employing an x-ray tube for measurement of trabecular bone mineral content. , 1982, Physics in medicine and biology.

[2]  A Fenster,et al.  Tomographic imaging of the angular-dependent coherent-scatter cross section. , 1997, Medical physics.

[3]  C. Constantinou Phantom materials for radiation dosimetry. I. Liquids and gels. , 1982, The British journal of radiology.

[4]  H Bernstein,et al.  On the significance of very small angle scattered radiation to radiographic imaging at low energies. , 1983, Medical physics.

[5]  R Tischler,et al.  Dual-energy Compton scatter tomography. , 1986, Physics in medicine and biology.

[6]  U Neitzel,et al.  Coherent scatter in radiographic imaging: a Monte Carlo simulation study. , 1985, Physics in medicine and biology.

[7]  M J Yaffe,et al.  Coherent scatter in diagnostic radiology. , 1983, Medical physics.

[8]  J. J. McInerney,et al.  A flying spot X-ray system for Compton backscatter imaging , 1994, IEEE Trans. Medical Imaging.

[9]  U Neitzel,et al.  X-ray diffraction measurements of some plastic materials and body tissues. , 1987, Medical physics.

[10]  L T Fitzgerald,et al.  Compton scatter axial tomography with x-rays: SCAT-CAT. , 1984, Physics in medicine and biology.

[11]  D. R. White,et al.  Tissue substitutes in experimental radiation physics. , 1978, Medical physics.

[12]  U Neitzel,et al.  Elastic scatter computed tomography. , 1985, Physics in medicine and biology.

[13]  J. H. Hubbell,et al.  Atomic form factors, incoherent scattering functions, and photon scattering cross sections , 1975 .

[14]  G. Harding,et al.  Elastic and Compton scattering with W Kα X-radiation , 1985 .

[15]  A. Berroir,et al.  Calculation of x-ray single scattering in diagnostic radiology. , 1983, Physics in medicine and biology.

[16]  Alan M. Jacobs,et al.  X-Ray Backscatter Imaging , 1981, IEEE Transactions on Biomedical Engineering.

[17]  M Danos,et al.  Image information content and patient exposure. , 1978, Medical physics.

[18]  A Karellas,et al.  Characterization of tissue via coherent-to-Compton scattering ratio: sensitivity considerations. , 1983, Medical physics.

[19]  A Fenster,et al.  Angular-dependent coherent scatter measured with a diagnostic x-ray image intensifier-based imaging system. , 1996, Medical physics.

[20]  J. H. Hubbell,et al.  Relativistic atomic form factors and photon coherent scattering cross sections , 1979 .

[21]  G. Harding,et al.  Status and outlook of coherent-x-ray scatter imaging. , 1987, Journal of the Optical Society of America. A, Optics and image science.

[22]  F T Farmer,et al.  A further appraisal of the Compton scattering method for determining anatomical cross-sections of the body. , 1974, Physics in medicine and biology.

[23]  Michael J. Bronskill,et al.  Compton scatter imaging of transverse sections: an overall appraisal and evaluation for radiotherapy planning , 1981 .

[24]  U Neitzel,et al.  X-ray diffraction computed tomography. , 1987, Medical physics.

[25]  D F Jackson,et al.  Assessment of gamma ray scattering for the characterisation of biological material. , 1983, Physics in medicine and biology.