Photoacoustic tomography of monkey brain using virtual point ultrasonic transducers.

A photoacoustic tomography system (PAT) using virtual point ultrasonic transducers was developed and applied to image a monkey brain. The custom-built transducers provide a 10-fold greater field-of-view (FOV) than finite-aperture unfocused transducers as well as an improved signal-to-noise ratio (SNR) and reduced artifacts rather than negative-lens transducers. Their tangential resolution, radial resolution, and (SNR) improvements were quantified using tissue phantoms. Our PAT system can achieve high uniformity in both resolution (<1 mm) and SNR (>8) within a large FOV of 6 cm in diameter, even when the imaging objects are enclosed by a monkey skull. The cerebral cortex of a monkey brain was accurately mapped transcranially, through a skull ranging from 2 to 4 mm in thickness. This study demonstrates that PAT can overcome the optical and ultrasound attenuation of a relatively thick skull and can potentially be applied to human neonatal brain imaging.

[1]  Geng Ku,et al.  Negative lens concept for photoacoustic tomography. , 2008, Physical review. E, Statistical, nonlinear, and soft matter physics.

[2]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Da Xing,et al.  Functional imaging of cerebrovascular activities in small animals using high-resolution photoacoustic tomography. , 2007, Medical physics.

[4]  Manojit Pramanik,et al.  Tangential resolution improvement in thermoacoustic and photoacoustic tomography using a negative acoustic lens. , 2009, Journal of biomedical optics.

[5]  Lihong V. Wang,et al.  Microwave-induced acoustic imaging of biological tissues , 1999 .

[6]  Fred P. Seeber,et al.  OP-TEC national center for optics and photonics education and ANSI Z136.5 American National Standard for the safe use of lasers in educational institutions – How they will work together to improve laser safety in educational institutions , 2009 .

[7]  Lihong V. Wang,et al.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging , 2006, Nature Biotechnology.

[8]  Xinmai Yang,et al.  Monkey brain cortex imaging by photoacoustic tomography. , 2008, Journal of biomedical optics.

[9]  Valery V Tuchin,et al.  In vivo photoacoustic flow cytometry for monitoring of circulating single cancer cells and contrast agents. , 2006, Optics letters.

[10]  Lihong V. Wang,et al.  Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain , 2003, Nature Biotechnology.

[11]  Benjamin A. Rockwell,et al.  A procedure for multiple-pulse maximum permissible exposure determination under the Z136.1-2000 American National Standard for Safe Use of Lasers , 2001 .

[12]  G.E. Trahey,et al.  Real time 3D ultrasound imaging of the brain , 2004, IEEE Ultrasonics Symposium, 2004.

[13]  Vasilis Ntziachristos,et al.  Multispectral photoacoustic imaging of fluorochromes in small animals. , 2007, Optics letters.

[14]  Richard Su,et al.  Whole-body three-dimensional optoacoustic tomography system for small animals. , 2009, Journal of biomedical optics.

[15]  Yuan Xu,et al.  Rhesus monkey brain imaging through intact skull with thermoacoustic tomography , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Patrick D Wolf,et al.  Feasibility study: real-time 3-D ultrasound imaging of the brain. , 2004, Ultrasound in medicine & biology.

[17]  Jan Laufer,et al.  Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration , 2007, Physics in medicine and biology.