Robustness of large-span timber roof structures — Structural aspects

Abstract Design rules for robustness require insensitivity to local failure and the prevention of progressive collapse. This is often verified by applying the load case “removal of a limited part of the structure”. This paper will evaluate typical structural systems for large-span timber roof structures against these requirements, comparing the results against typical reasons for damages and failures. Applying the finding that most failures of timber structures are not caused by random occurrences or local defects, but by global (repetitive) defects (e.g. from systematic mistakes), it is shown that the objective of load transfer–often mentioned as preferable–should be critically analysed for such structures. Based on these findings, proposals for structural systems and details towards a robust design of large-span timber roof structures are given.

[1]  Stefan Winter,et al.  Assessment of the Structural Reliability of all wide span Timber Structures under the Responsibility of the City of Munich , 2009 .

[2]  Bruce R. Ellingwood DESIGN AND CONSTRUCTION ERROR EFFECTS ON STRUCTURAL RELIABILITY , 1987 .

[3]  Stefan Winter,et al.  Robustness of Secondary Structures in wide-span Timber Structures. , 2010 .

[4]  Martin Hansson,et al.  Recent failures in glulam structures and their causes , 2005 .

[5]  Sven Thelandersson,et al.  Design of safe timber structures - How can we learn from structural failures in concrete, steel and timber? , 2007 .

[6]  H. J. Larsen Timber Engineering. STEP 2. Design - details and structural systems. , 1995 .

[7]  Philipp Dietsch,et al.  Robustness of large-span timber roof structures - Two examples. , 2011 .

[8]  H. J. Larsen,et al.  DS/ENV 1995-1-1 NAD National Application Document for Eurocode 5: Design of Timber Structures, Part 1-1: General Rules and Rules for Buildings , 1994 .

[9]  Uwe Starossek,et al.  Progressive Collapse of Structures: Nomenclature and Procedures , 2006 .

[10]  Stefan Winter,et al.  The Bad Reichenhall ice-arena collapse and the necessary consequences for wide span timber structures , 2008 .

[11]  Daniel Straub,et al.  Comparative risk assessment of secondary structures in wide-span timber structures , 2011 .

[12]  Hans Joachim Blaß,et al.  Statistics of damages to timber structures in Germany , 2011 .

[13]  Aitc Timber Construction Manual , 2004 .