Volume Dependence of High-Frequency Respiratory Mechanics in Healthy Adults

Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5–302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.

[1]  K. Lutchen,et al.  Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerations. , 1988, Journal of applied physiology.

[2]  M. Silverman,et al.  Differences in airway wall compliance as a possible mechanism for wheezing disorders in infants. , 1998, The European respiratory journal.

[3]  B Suki,et al.  Serial distribution of airway mechanical properties in dogs: effects of histamine. , 1994, Journal of applied physiology.

[4]  B Suki,et al.  Human respiratory impedance from 8 to 256 Hz corrected for upper airway shunt. , 1989, Journal of applied physiology.

[5]  C. Mackenzie,et al.  Effect of Lung Volume on Lung Resistance and Elastance in Awake Subjects Measured during Sinusoidal Forcing , 1993, Anesthesiology.

[6]  K. P. Van de Woestijne,et al.  Oscillating Flow of a Viscous Compressible Fluid Through a Rigid Tube: A Theoretical Model , 1981, IEEE Transactions on Biomedical Engineering.

[7]  K. P. Van de Woestijne,et al.  Variations of respiratory impedance with lung volume in bronchial hyperreactivity. , 1990, Chest.

[8]  K. Lutchen,et al.  Selected contribution: airway caliber in healthy and asthmatic subjects: effects of bronchial challenge and deep inspirations. , 2001, Journal of applied physiology.

[9]  A. Jackson,et al.  Deep breath reversal and exponential return of methacholine-induced obstruction in asthmatic and nonasthmatic subjects. , 2004, Journal of applied physiology.

[10]  R. Habib,et al.  Respiratory input impedance from 4 to 256 Hz in normals and chronic airflow obstruction: comparisons and correlations with spirometry. , 1992, The American review of respiratory disease.

[11]  J. Fredberg,et al.  Mechanical impedance of the lung periphery. , 1997, Journal of applied physiology.

[12]  T Kaneko,et al.  Input acoustic-impedance measurement of the subglottal system. , 1976, The Journal of the Acoustical Society of America.

[13]  Jeffrey J. Fredberg Acoustic determinants of respiratory system properties , 2006, Annals of Biomedical Engineering.

[14]  A MODIFICATION OF THE FORCED OSCILLATION TECHNIQUE , 1981 .

[15]  E. Oostveen,et al.  The forced oscillation technique in clinical practice: methodology, recommendations and future developments , 2003, European Respiratory Journal.

[16]  J. Bates,et al.  Time course of airway mechanics of the (+)insert myosin isoform knockout mouse. , 2004, American journal of respiratory cell and molecular biology.

[17]  A. B. Dubois,et al.  The relationship between airway resistance, airway conductance and lung volume in subjects of different age and body size. , 1958, The Journal of clinical investigation.

[18]  B. Suki,et al.  Airway geometry and wall mechanical properties estimated from subglottal input impedance in humans. , 1994, Journal of applied physiology.

[19]  Z Hantos,et al.  Volume dependence of respiratory impedance in infants. , 1997, American journal of respiratory and critical care medicine.

[20]  J. Bates,et al.  High-frequency characteristics of respiratory mechanics determined by flow interruption. , 1990, Journal of applied physiology.

[21]  G. R. Srinivasan,et al.  A microscopic model of energy deposition in silicon slabs exposed to high-energy protons , 1987 .

[22]  A. Jackson,et al.  Density dependence of respiratory system impedances between 5 and 320 Hz in humans. , 1989, Journal of applied physiology.

[23]  R Peslin,et al.  Within-breath variations of forced oscillation resistance in healthy subjects. , 1992, The European respiratory journal.

[24]  E BERGLUND,et al.  Spirometric studies in normal subjects. I. Forced expirograms in subjects between 7 and 70 years of age. , 2009, Acta medica Scandinavica.

[25]  Cindy Thamrin,et al.  Volume dependence of airway and tissue impedances in mice. , 2003, Journal of applied physiology.

[26]  E D Michaelson,et al.  Pulmonary mechanics by spectral analysis of forced random noise. , 1975, The Journal of clinical investigation.

[27]  D. Navajas,et al.  Respiratory input impedance up to 256 Hz in healthy humans breathing foreign gases. , 1993, Journal of applied physiology.

[28]  K. Lutchen,et al.  Modeling of respiratory system impedances in dogs. , 1987, Journal of applied physiology.

[29]  Z. Hantos,et al.  Tracking of airway and tissue mechanics during TLC maneuvers in mice. , 2003, Journal of applied physiology.

[30]  J L Hankinson,et al.  Spirometric reference values from a sample of the general U.S. population. , 1999, American journal of respiratory and critical care medicine.

[31]  John Everard Cotes,et al.  Handbook of Pulmonary Drug Therapy , 1993, Thorax.

[32]  G. Grimby,et al.  Spirometric Studies in Normal Subjects , 2009 .

[33]  A. W. Brody,et al.  Oscillation mechanics of lungs and chest in man. , 1956, Journal of applied physiology.