Modeling the performance of accommodating intraocular lenses

Purpose. Pseudo-accommodating intra-ocular lenses (P-IOL) have been available for some time and the availability of accommodating IOL (A-IOL) is imminent. While these types of devices have been tested empirically, few studies have addressed the fundamental parameters governing their performance limits. We modelled the amplitude of accommodation of A-IOLs and P-IOLs to analyse parameters controlling their performance. Methods. Two types of two-element A-IOLs (those with a mobile anterior optical element, or a mobile posterior element) were modelled. Paraxial models were developed to identify key controlling parameters and potential optimal configurations, followed by finite modelling using computer assisted ray-tracing employing equi-convex/concave optical elements. A range of configurations representing varying focal lengths of front and back optical elements were tested. Degenerate cases representing P-IOLs were also tested. Results. P-IOLs have limited rate of pseudo-accommodation with axial shift (approximately 1.2D/mm). For A-IOLs, configurations with positive power front elements returned best rate of accommodation (up to approximately 3.0D/mm when the front element focal length is 25 mm). Conclusions. Considering the maximum potential amounts of axial shifts available, P-IOLs were predicted to provide less than 1D of accommodation whereas A-IOLs may provide up to 3-4D of accommodation, depending on design configuration.

[1]  Nhung X Nguyen,et al.  Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens , 2003, Journal of cataract and refractive surgery.

[2]  Faezeh Mona Sarfarazi Sarfarazi Elliptical Accommodative Intraocular Lens , 2005 .

[3]  Adrian Glasser,et al.  Sarfarazi Elliptical Accommodating IntraOcular Lens (EAIOL) in Rhesus Monkey Eyes In Vitro and In Vivo , 2003 .

[4]  Nhung X Nguyen,et al.  Implantation of a new accommodative posterior chamber intraocular lens. , 2002, Journal of refractive surgery.

[5]  J S Cumming,et al.  Clinical evaluation of the model AT-45 silicone accommodating intraocular lens: results of feasibility and the initial phase of a Food and Drug Administration clinical trial. , 2001, Ophthalmology.

[6]  F. Roy,et al.  Mechanism of accommodation in primates. , 2001, Ophthalmology.

[7]  E I Assia,et al.  Accommodative intraocular lens: A challenge for future development , 1997, Journal of cataract and refractive surgery.

[8]  Wolfgang Drexler,et al.  Intraocular lens movement caused by ciliary muscle contraction , 2003, Journal of cataract and refractive surgery.

[9]  Y. Yamada,et al.  Accommodative intraocular lens with spring action--Part 2. Fixation in the living rabbit. , 1992, Ophthalmic surgery.

[10]  H Lesiewska-Junk,et al.  Intraocular lens movement and accommodation in eyes of young patients , 2000, Journal of cataract and refractive surgery.

[11]  R. Navarro,et al.  Accommodation-dependent model of the human eye with aspherics. , 1985, Journal of the Optical Society of America. A, Optics and image science.

[12]  D. J. Apple,et al.  Miyake-Apple-Video-Analyse des Bewegungsmusters einer akkommodativen Intraokularlinse , 2002, Der Ophthalmologe.