Aspects of steady-state operation of the Wendelstein 7-X stellarator

The objective of Wendelstein 7-X is to demonstrate steady-state operation at β -values of up to 5%, at ion temperatures of several keV and plasma densities of up to 2 × 1020 m−3. The second operational phase foresees a fully steady-state high heat flux (HHF) divertor. Preparations are underway to cope with residual bootstrap currents, either by electron cyclotron current drive or by HHF protection elements. The main steady-state heating system is an electron cyclotron resonance heating facility. Various technical improvements of the gyrotrons have been implemented recently. They enable a reliable operation at the 1 MW power level. Some of the technical issues preparing plasma diagnostics for steady-state operation are exemplified. This includes the protection against non-absorbed microwave radiation.

[1]  C. D. Beidler,et al.  Current Control by ECCD for W7-X , 2006 .

[2]  G. Gantenbein,et al.  Electron Cyclotron Heating for W7-X: Physics and Technology , 2007 .

[3]  F L Tabarés,et al.  Tritium inventory control during ITER operation under carbon plasma-facing components by nitrogen-based plasma chemistry: a review , 2013 .

[4]  Stefan Illy,et al.  140 GHz, 1 MW CW Gyrotron Development for Fusion Applications—Progress and Recent Results , 2011 .

[5]  F. Sardei,et al.  Physics and Engineering Design for Wendelstein VII-X , 1990 .

[6]  H. P. Laqua,et al.  Distribution of the ECRH Stray Radiation in Fusion Devices , 2001 .

[7]  L. Giannone,et al.  Physics optimization of stellarators , 1992 .

[8]  C. D. Beidler,et al.  Effects of Net Currents on the Magnetic Configuration of W7‐X , 2010 .

[9]  R. C. Wolf,et al.  A stellarator reactor based on the optimization criteria of Wendelstein 7-X , 2008 .

[10]  A. Werner,et al.  W7-X Magnetic Diagnostics: Performance of the Digital Integrator , 2006 .

[11]  A. Loarte,et al.  Preliminary results of the experimental study of PFCs exposure to ELMs-like transient loads followed by high heat flux thermal fatigue , 2011 .

[12]  H.-S. Bosch,et al.  Physics Programme for Initial Operation of Wendelstein 7‐X , 2010 .

[13]  J. Boscary,et al.  A proposed scraper element to protect the end of the W7-X divertor target elements , 2011, 2011 IEEE/NPSS 24th Symposium on Fusion Engineering.

[14]  M. Hirsch,et al.  Problems with ECRH stray radiation in Wendelstein 7-X , 2003 .

[15]  W. Biel,et al.  First results from the modular multi-channel dispersion interferometer at the TEXTOR tokamak. , 2011, The Review of scientific instruments.

[16]  A. Werner,et al.  Diagnostics for steady state plasmas , 2006 .

[17]  M. Hirsch,et al.  Design criteria of the bolometer diagnostic for steady-state operation of the W7-X stellarator. , 2010, The Review of scientific instruments.

[18]  J. Svensson,et al.  Diagnostics design for steady-state operation of the Wendelstein 7-X stellarator. , 2010, The Review of scientific instruments.

[19]  J. Roth,et al.  Deuterium inventory in Tore Supra: reconciling particle balance and post-mortem analysis , 2009 .