Top-orthogonal-to-bottom-electrode (TOBE) CMUT arrays for 3-D ultrasound imaging
暂无分享,去创建一个
Roger Zemp | Peiyu Zhang | Alex Sampaleanu | Abhijeet Kshirsagar | Walied Moussa | R. Zemp | W. Moussa | A. Kshirsagar | Peiyu Zhang | Alexander Sampaleanu | Abhijeet Kshirsagar
[1] A. Savoia,et al. P2B-4 Crisscross 2D cMUT Array: Beamforming Strategy and Synthetic 3D Imaging Results , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.
[2] S. Ergun,et al. Highly integrated 2-D capacitive micromachined ultrasonic transducers , 1999, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027).
[3] S.W. Smith,et al. High-speed ultrasound volumetric imaging system. I. Transducer design and beam steering , 1991, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[4] K. Thomenius,et al. Evolution of ultrasound beamformers , 1996, 1996 IEEE Ultrasonics Symposium. Proceedings.
[5] J. Jensen,et al. Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[6] I. Ladabaum,et al. Micromachined capacitive transducer arrays for medical ultrasound imaging , 1998, 1998 IEEE Ultrasonics Symposium. Proceedings (Cat. No. 98CH36102).
[7] S.W. Smith,et al. Sparse 2-D array design for real time rectilinear volumetric imaging , 2000, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[8] T. Harrison,et al. Double-SOI Wafer-Bonded CMUTs With Improved Electrical Safety and Minimal Roughness of Dielectric and Electrode Surfaces , 2012, Journal of Microelectromechanical Systems.
[9] O. Oralkan,et al. 3-D ultrasound imaging using a forward-looking CMUT ring array for intravascular/intracardiac applications , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[10] P. Wolf,et al. A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[11] J.T. Yen,et al. 2-D array for 3-D ultrasound imaging using synthetic aperture techniques , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[12] O. Oralkan,et al. Capacitive micromachined ultrasonic transducer design for high power transmission , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[13] P5J-4 256x256 2-D Array Transducer with Row-Column Addressing for 3-D Imaging , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.
[14] K. Boone,et al. Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study , 1996, Medical and Biological Engineering and Computing.
[15] O. V. von Ramm,et al. Theory and operation of 2-D array piezoelectric micromachined ultrasound transducers , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[16] J.T. Yen,et al. A dual-layer transducer array for 3-D rectilinear imaging , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[17] J. Arendt. Paper presented at the 10th Nordic-Baltic Conference on Biomedical Imaging: Field: A Program for Simulating Ultrasound Systems , 1996 .
[18] Jørgen Arendt Jensen,et al. Investigation of the feasibility of 3D synthetic aperture imaging , 2003, IEEE Symposium on Ultrasonics, 2003.
[19] O. Oralkan,et al. Integration of 2D CMUT arrays with front-end electronics for volumetric ultrasound imaging , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[20] G.R. Lockwood,et al. Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[21] O. Oralkan,et al. Volumetric ultrasound imaging using 2-D CMUT arrays , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[22] John T. W. Yeow,et al. 2-D CMUT wafer bonded imaging arrays with a row-column addressing scheme , 2009, 2009 IEEE International Ultrasonics Symposium.
[23] M. Pappalardo,et al. Element shape design of 2-D CMUT arrays for reducing grating lobes , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[24] B. Khuri-Yakub,et al. Characterization of one-dimensional capacitive micromachined ultrasonic immersion transducer arrays , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[25] T. Harrison,et al. The applicability of ultrasound dynamic receive beamformers to photoacoustic imaging , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[26] Feasibility of Top-Orthogonal-to-Bottom Electrode (TOBE) 2D CMUT arrays for low-channel-count 3D imaging , 2011 .
[27] B. Khuri-Yakub,et al. Finite element modeling and experimental characterization of crosstalk in 1-D CMUT arrays , 2007, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[28] J. Yeow,et al. A 32 x 32 element row-column addressed capacitive micromachined ultrasonic transducer , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.
[29] A. Fenster,et al. 3-D ultrasound imaging: a review , 1996 .