Study on the Estimation of Utility Harmonic Impedance Based on Minimum Norm of Impedance Difference

The existing methods for estimating harmonic impedance usually assume that harmonic impedance is constant in a measurement period. However, for a variety of practical reasons, such as the load change of power grid, utility harmonic impedance may be changed. So a reasonable hypothesis is that utility harmonic impedance is time-varying, but the variation of the impedance is not large at adjacent sampling time. Thus, this paper proposes a novel method to estimate utility harmonic impedance by taking the criterion of minimum norm of impedance differences at adjacent sampling times with a measurement period. According to the proposed criterion, an objective function is built with the norm of the harmonic impedance differences and utility harmonic voltage differences of adjacent moments. And then, the utility harmonic impedance can be obtained by minimizing the objective function. The proposed method has high accuracy even while background harmonic emission level is high and harmonic impedance of customer side is not much larger than that of utility side. The effectiveness is verified by the simulation and field cases. In the simulation, the estimation errors of most cases are within 10% and the maximum error is not exceed 16%.

[1]  Carlo Muscas Power quality monitoring in modern electric distribution systems , 2010, IEEE Instrumentation & Measurement Magazine.

[2]  Li Yonggang,et al.  Research on the responsibility partition of harmonic pollution and harmonic impedance based on the total least-squares regression method , 2014, 2014 International Conference on Power System Technology.

[3]  Honggeng Yang,et al.  Assessing Utility Harmonic Impedance Based on the Covariance Characteristic of Random Vectors , 2010, IEEE Transactions on Power Delivery.

[4]  Kaveh Malekian,et al.  On the Dominant Harmonic Source Identification—Part II: Application and Interpretation of Methods , 2018, IEEE Transactions on Power Delivery.

[5]  Carlo Muscas,et al.  Investigation on the accuracy of harmonic pollution metering techniques , 2004, IEEE Transactions on Instrumentation and Measurement.

[6]  Seyed Hossein Hosseinian,et al.  A Novel Method for Noninvasive Estimation of Utility Harmonic Impedance Based on Complex Independent Component Analysis , 2015, IEEE Transactions on Power Delivery.

[7]  Wilsun Xu,et al.  Harmonic impedance measurement using a thyristor-controlled short circuit , 2007 .

[8]  Chen Yang,et al.  Quantifying Harmonic Responsibilities Based on Kurtosis Detection Principle of Amplitude Fluctuations , 2018, IEEE Access.

[9]  B. Blazic,et al.  Harmonic Contributions Evaluation With the Harmonic Current Vector Method , 2008, IEEE Transactions on Power Delivery.

[10]  Hualin Gong,et al.  A New Assessment Method of Customer Harmonic Emission Level , 2010, 2010 Asia-Pacific Power and Energy Engineering Conference.

[11]  Minhan Yoon,et al.  A Novel Method for Assessing the Contribution of Harmonic Sources to Voltage Distortion in Power Systems , 2020, IEEE Access.

[12]  Hasan Dirik,et al.  A Computation and Metering Method for Harmonic Emissions of Individual Consumers , 2019, IEEE Transactions on Instrumentation and Measurement.

[13]  Johan Rens,et al.  Continuous Event-Based Harmonic Impedance Assessment Using Online Measurements , 2016, IEEE Transactions on Instrumentation and Measurement.

[14]  Honggeng Yang,et al.  A New Method to Calculate the Utility Harmonic Impedance Based on FastICA , 2016, IEEE Transactions on Power Delivery.

[15]  W. Xu,et al.  Harmonic impedance measurement using three-phase transients , 1998 .

[16]  Zhengyou He,et al.  Adaptive method for harmonic contribution assessment based on hierarchical K -means clustering and Bayesian partial least squares regression , 2016 .

[17]  Johan Rens,et al.  Harmonic impedance assessment using prevailing phasors , 2018, 2018 18th International Conference on Harmonics and Quality of Power (ICHQP).

[18]  Yao Xiao,et al.  Harmonic impedance measurement using voltage and current increments from disturbing loads , 2000, Ninth International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.00EX441).

[19]  Edson Guedes da Costa,et al.  Estimation of the Utility's and Consumer's Contribution to Harmonic Distortion , 2007, 2007 IEEE Instrumentation & Measurement Technology Conference IMTC 2007.

[20]  Hossein Mokhtari,et al.  Technique for online tracking of a utility harmonic impedance using by synchronising the measured samples , 2016 .

[21]  Zhiqi Wang,et al.  Study on Constraints for Harmonic Source Determination Using Active Power Direction , 2018, IEEE Transactions on Power Delivery.

[22]  Yi Pan,et al.  Multi-Harmonic Sources Harmonic Contribution Determination Based on Data Filtering and Cluster Analysis , 2019, IEEE Access.

[23]  Liu Yingying,et al.  Partial Least-Squares Regression Based Harmonic Emission Level Assessing at the Point of Common Coupling , 2006, 2006 International Conference on Power System Technology.

[24]  Hossein Mokhtari,et al.  New method for assessing the utility harmonic impedance based on fuzzy logic , 2017 .

[25]  Kaveh Malekian,et al.  On the Dominant Harmonic Source Identification— Part I: Review of Methods , 2018, IEEE Transactions on Power Delivery.

[26]  Shun Tao,et al.  Study on Harmonic Impedance Estimation and Harmonic Contribution Evaluation Index , 2020, IEEE Access.

[27]  Wentao Lv,et al.  Study on the Verification of the Calculated Harmonic Impedance , 2020, IEEE Access.

[28]  Ross T. Whitaker,et al.  Curve Boxplot: Generalization of Boxplot for Ensembles of Curves , 2014, IEEE Transactions on Visualization and Computer Graphics.

[29]  Saeid Esmaeili,et al.  Method for determining utility and consumer harmonic contributions based on complex independent component analysis , 2016 .