Ambient vibration test and finite element modeling of tall liquid storage tanks

This paper addresses the experimental and numerical investigations of the dynamic parameters, natural frequencies and mode shapes, of fixed roof, ground supported, steel storage tanks. Three tall liquid storage tanks with aspect ratios greater than unity are considered. The considered tanks have similar height of 12.190 m and different radius of 6.095, 8.00, and 9.144 m. The effect of the aspect ratio, along with the liquid level on dynamic parameters is discussed. Finite element models of tanks are constructed using the finite element package ANSYS. The fluid-structure interaction is governed in the models. Yet, before using numerical techniques for analyzing the tank-liquid systems, they should be validated by experimental results. For this purpose, a series of ambient vibration tests are carried out to determine the natural frequencies and, if possible, the modes of the vibration. Comparison between numerical and experimental values shows good agreement. The new feature considered in the paper is the influence of roof on the natural frequencies and the modes of vibration. It is found that the influence of roof on the natural frequency of vibration of the considered tanks is negligible, while it does restrain the tank top against radial deformations and has significant effect on the mode shapes of tank.

[1]  Luis A. Godoy,et al.  Fundamental modes of tank-liquid systems under horizontal motions , 2006 .

[2]  Medhat A. Haroun Dynamic analyses of liquid storage tanks , 1980 .

[3]  Ali M. Memari,et al.  Full-scale dynamic testing of a steel frame building during construction , 1999 .

[4]  Carlos E. Ventura,et al.  Damping estimation by frequency domain decomposition , 2001 .

[5]  Medhat A. Haroun,et al.  Seismic Design of Liquid Storage Tanks , 1981 .

[6]  Carmelo Gentile,et al.  Ambient vibration testing of historic masonry towers for structural identification and damage assessment , 2007 .

[7]  G. Housner The dynamic behavior of water tanks , 1963 .

[8]  Zuhal Ozdemir,et al.  Application of nonlinear fluid–structure interaction methods to seismic analysis of anchored and unanchored tanks , 2010 .

[9]  Maria I. Todorovska,et al.  Ambient vibration tests of a seven-story reinforced concrete building in Van Nuys, California, damaged by the 1994 Northridge earthquake , 2000 .

[10]  Carmelo Gentile,et al.  Ambient vibration testing and structural evaluation of an historic suspension footbridge , 2008, Adv. Eng. Softw..

[11]  B A Cunha,et al.  The atypical pneumonias: clinical diagnosis and importance , 2006, Clinical Microbiology and Infection.

[12]  Praveen K. Malhotra,et al.  Simple Procedure for Seismic Analysis of Liquid-Storage Tanks , 2000 .

[13]  Mohammad Ali Goudarzi,et al.  Evaluating 3D Earthquake Effects on Sloshing Wave Height of Liquid Storage Tanks Using Finite Element Method , 2008 .

[14]  Qiusheng Li,et al.  Finite element model updating for a high-rise structure based on ambient vibration measurements , 2004 .

[15]  John H G Macdonald,et al.  Variation of modal parameters of a cable-stayed bridge identified from ambient vibration measurements and FE modelling , 2005 .

[16]  Medhat A. Haroun,et al.  Complications in Free Vibration Analysis of Tanks , 1982 .

[17]  Carlos E. Ventura,et al.  Dynamic characteristics of a base isolated building from ambient vibration measurements and low level earthquake shaking , 2003 .

[18]  George W. Housner,et al.  AN ANALYSIS OF THE DYNAMIC CHARACTERISTICS OF A SUSPENSION BRIDGE BY AMBIENT VIBRATION MEASUREMENTS , 1977 .

[19]  Luis A. Godoy,et al.  Influence of the roof on the natural periods of empty steel tanks , 2003 .

[20]  J.W. LEE,et al.  HEALTH-MONITORING METHOD FOR BRIDGES UNDER ORDINARY TRAFFIC LOADINGS , 2002 .

[21]  Helmut Wenzel,et al.  Ambient Vibration Monitoring , 2005 .

[22]  Yozo Fujino,et al.  System identification of suspension bridge from ambient vibration response , 2008 .

[23]  Wei-Xin Ren,et al.  Dynamic and seismic performance of old multi-tiered temples in Nepal , 2003 .

[24]  D. P. Clough Experimental evaluation of seismic design methods for broad cylindrical tanks , 1977 .

[25]  M. Celebi,et al.  Before and after retrofit - response of a building during ambient and strong motions , 1998 .