Dual-frequency resonance-tracking atomic force microscopy

A dual-excitation method for resonant-frequency tracking in scanning probe microscopy based on amplitude detection is developed. This method allows the cantilever to be operated at or near resonance for techniques where standard phase locked loops are not possible. This includes techniques with non-acoustic driving where the phase of the driving force is frequency and/or position dependent. An example of the latter is piezoresponse force microscopy (PFM), where the resonant frequency of the cantilever is strongly dependent on the contact stiffness of the tip–surface junction and the local mechanical properties, but the spatial variability of the drive phase rules out the use of a phase locked loop. Combined with high-voltage switching and imaging, dual-frequency, resonance-tracking PFM allows reliable studies of electromechanical and elastic properties and polarization dynamics in a broad range of inorganic and biological systems, and is illustrated using lead zirconate–titanate, rat tail collagen, and native and switched ferroelectric domains in lithium niobate.

[1]  Stephen Jesse,et al.  Resonance enhancement in piezoresponse force microscopy: Mapping electromechanical activity, contact stiffness, and Q factor , 2006 .

[2]  K. Terabe,et al.  Surface potential imaging of nanoscale LiNbO3 domains investigated by electrostatic force microscopy , 2006 .

[3]  Roger Proksch,et al.  Multifrequency, repulsive-mode amplitude-modulated atomic force microscopy , 2006 .

[4]  Gil Rosenman,et al.  Piezoelectric Effect in Human Bones Studied in Nanometer Scale , 2004 .

[5]  Stephen Jesse,et al.  Dynamic behaviour in piezoresponse force microscopy. , 2006, Nanotechnology.

[6]  M. Alexe,et al.  Contact resonances in voltage-modulated force microscopy , 2003 .

[7]  Alexei Gruverman,et al.  Nanoscale ferroelectrics: processing, characterization and future trends , 2006 .

[8]  Ute Rabe,et al.  Influence of the cantilever holder on the vibrations of AFM cantilevers , 2007 .

[9]  David A. Scrymgeour,et al.  Nanoscale piezoelectric response across a single antiparallel ferroelectric domain wall , 2005, cond-mat/0503230.

[10]  Ute Rabe,et al.  Acoustic microscopy by atomic force microscopy , 1994 .

[11]  H. K. Wickramasinghe,et al.  Kelvin probe force microscopy , 1991 .

[12]  M. Allegrini,et al.  Domain pattern formation and kinetics on ferroelectric surfaces under thermal cycling using scanning force microscopy , 2002 .

[13]  D. Rugar,et al.  Frequency modulation detection using high‐Q cantilevers for enhanced force microscope sensitivity , 1991 .

[14]  Sergei V. Kalinin,et al.  Electromechanical imaging of biomaterials by scanning probe microscopy. , 2006, Journal of structural biology.

[15]  Ricardo Garcia,et al.  Compositional mapping of surfaces in atomic force microscopy by excitation of the second normal mode of the microcantilever , 2004 .