Thermo-economic and environmental analyses based multi-objective optimization of vapor compression–absorption cascaded refrigeration system using NSGA-II technique

Abstract Present work optimizes the performance of 170 kW vapor compression–absorption cascaded refrigeration system (VCACRS) based on combined thermodynamic, economic and environmental parameters using Non-dominated Sort Genetic Algorithm-II (NSGA-II) technique. Two objective functions including the total irreversibility rate (as a thermodynamic criterion) and the total product cost (as an economic criterion) of the system are considered simultaneously for multi-objective optimization of VCACRS. The capital and maintenance costs of the system components, the operational cost, and the penalty cost due to CO 2 emission are included in the total product cost of the system. Three optimized systems including a single-objective thermodynamic optimized, a single-objective economic optimized and a multi-objective optimized are analyzed and compared. The results showed that the multi-objective design considers the combined thermodynamic and total product cost criteria better than the two individual single-objective thermodynamic and total product cost optimized designs.

[1]  Pekka Ruohonen,et al.  Determination of the Real Loss of Power for a Condensing and a Backpressure Turbine by Means of Second Law Analysis , 2009, Entropy.

[2]  Olcay Kincay,et al.  Thermoeconomic optimization of LiBr/H2O-R134a compression-absorption cascade refrigeration cycle , 2015 .

[3]  V. Gnielinski New equations for heat and mass transfer in turbulent pipe and channel flow , 1976 .

[4]  Sepehr Sanaye,et al.  Thermal and economical optimization of air conditioning units with vapor compression refrigeration system , 2004 .

[5]  Surendra Singh Kachhwaha,et al.  Thermodynamic performance analysis of a vapor compression–absorption cascaded refrigeration system , 2013 .

[6]  Yingying Tan,et al.  Study on Solar-Assisted Cascade Refrigeration System , 2012 .

[7]  J. Paris,et al.  A model for analysis and design of H2O–LiBr absorption heat pumps , 2011 .

[8]  Majid Amidpour,et al.  Thermoeconomic analysis and optimization of an ammonia–water power/cooling cogeneration cycle , 2012 .

[9]  Rabah Gomri,et al.  Second law analysis of double effect vapour absorption cooler system , 2008 .

[10]  Hongguang Jin,et al.  A New Absorption–compression Refrigeration System Using a Mid-temperature Heat Source for Freezing Application , 2015 .

[11]  Frank P. Incropera,et al.  Fundamentals of Heat and Mass Transfer , 1981 .

[12]  Fabio Rinaldi,et al.  Exergetic, economic and environmental (3E) analyses, and multi-objective optimization of a CO2/NH3 cascade refrigeration system , 2014 .

[13]  Ilhan Ozturk,et al.  Analysis of compression–absorption cascade refrigeration cycles , 2012 .

[14]  M. Ameri,et al.  Analysis of integrated compression–absorption refrigeration systems powered by a microturbine , 2012 .

[15]  V. Zare,et al.  Standard GAX versus hybrid GAX absorption refrigeration cycle: From the view point of thermoeconomics , 2013 .

[16]  R. D. Misra,et al.  Thermoeconomic Optimization of a LiBr/H2O Absorption Chiller Using Structural Method , 2005 .

[17]  Selahattin Göktun,et al.  The optimum performance of a solar-assisted combined absorption–vapor compression system for air conditioning and space heating , 2001 .

[18]  Suresh V. Garimella,et al.  Multi-objective optimization of sustainable single-effect water/Lithium Bromide absorption cycle , 2012 .

[19]  Georgios A. Florides,et al.  Design and construction of a LiBr–water absorption machine , 2003 .

[20]  Surendra Singh Kachhwaha,et al.  Performance analysis of a vapour compression-absorption cascaded refrigeration system with undersized evaporator and condenser , 2017 .

[21]  Srinivas Garimella,et al.  Waste heat driven absorption/vapor-compression cascade refrigeration system for megawatt scale, high-flux, low-temperature cooling , 2011 .

[22]  Pooya Hoseinpoori,et al.  Energy and cost optimization of a plate and fin heat exchanger using genetic algorithm , 2011 .

[23]  Mehran Ameri,et al.  Energy and exergy comparison of a cascade air conditioning system using different cooling strategies , 2014 .

[24]  Rabah Gomri,et al.  Simulation study on the performance of solar/natural gas absorption cooling chillers , 2013 .

[25]  S. C. Kaushik,et al.  Multi-objective and multi-parameter optimization of two-stage thermoelectric generator in electrically series and parallel configurations through NSGA-II , 2015 .

[26]  Yiping Dai,et al.  Multi-objective optimization of a combined cooling, heating and power system driven by solar energy , 2015 .

[27]  José Fernández-Seara,et al.  Compression–absorption cascade refrigeration system , 2006 .

[28]  Alberto Coronas,et al.  Integration of trigeneration in an indirect cascade refrigeration system in supermarkets , 2011 .

[29]  S.M.S. Mahmoudi,et al.  Exergoeconomic analysis and multi-objective optimization of an ejector refrigeration cycle powered by an internal combustion (HCCI) engine , 2015 .

[30]  G. Alefeld,et al.  Experimental investigation of heat transfer in a horizontal tube falling film absorber with aqueous solutions of LiBr with and without surfactants , 1996 .

[31]  Juan M. Belman-Flores,et al.  NLP model of a LiBr–H2O absorption refrigeration system for the minimization of the annual operating cost , 2012 .

[32]  S. S. Murthy,et al.  Solar-assisted vapor compression/absorption cascaded air-conditioning systems , 1993 .

[33]  Surendra Singh Kachhwaha,et al.  NLP model based thermoeconomic optimization of vapor compression–absorption cascaded refrigeration system , 2015 .

[34]  Thanarath Sriveerakul,et al.  Experimental studies of a single-effect absorption refrigerator using aqueous lithium–bromide: Effect of operating condition to system performance , 2007 .

[35]  Wilfrido Rivera,et al.  Performance comparison between a conventional vapor compression and compression-absorption single-stage and double-stage systems used for refrigeration , 2015 .

[36]  Yanbin Yuan,et al.  An extended NSGA-III for solution multi-objective hydro-thermal-wind scheduling considering wind power cost , 2015 .

[37]  Surendra Singh Kachhwaha,et al.  Exergy analysis of a vapour compression–absorption cascaded refrigeration system using modified Gouy–Stodola equation , 2014 .

[38]  Syed M. Zubair,et al.  Design and performance evaluation of reciprocating refrigeration systems , 1999 .

[39]  Gade Pandu Rangaiah,et al.  Design of shell-and-tube heat exchangers for multiple objectives using elitist non-dominated sorting genetic algorithm with termination criteria , 2016 .

[40]  Soteris A. Kalogirou,et al.  Thermoeconomic optimization of a LiBr absorption refrigeration system , 2007 .

[41]  Guangming Chen,et al.  Experimental study on HFC-161 mixture as an alternative refrigerant to R502 , 2005 .

[42]  E. Nehdi,et al.  Cooling performance and energy saving of a compression–absorption refrigeration system assisted by geothermal energy , 2006 .

[43]  D. Colorado,et al.  Exergy analysis of a compression–absorption cascade system for refrigeration , 2013 .

[44]  Surendra Singh Kachhwaha,et al.  Energy, exergy, economic and environmental (4E) analyses based comparative performance study and optimization of vapor compression-absorption integrated refrigeration system , 2015 .

[45]  Hoseyn Sayyaadi,et al.  Multi-objective optimization of a cooling tower assisted vapor compression refrigeration system , 2011 .

[46]  Surendra Singh Kachhwaha,et al.  Thermodynamic modelling and parametric study of a low temperature vapour compression-absorption system based on modified Gouy-Stodola equation , 2015 .

[47]  W. Rohsenow,et al.  Handbook of Heat Transfer , 1998 .

[48]  Berhane H. Gebreslassie,et al.  Design of environmentally conscious absorption cooling systems via multi-objective optimization and life cycle assessment , 2009 .