Experimental and analytical studies on multiple tuned mass dampers for seismic protection of porcelain electrical equipment
暂无分享,去创建一个
Wen Bai | Yongqiang Yang | Junwu Dai | Huimeng Zhou | Xiaoqing Ning | J. Dai | X. Ning | Yongqiang Yang | Huimeng Zhou | W. Bai
[1] R. Mohammadi-Ghazi,et al. A novel semi-active TMD with folding variable stiffness spring , 2014, Earthquake Engineering and Engineering Vibration.
[2] Peter Hagedorn,et al. On the hysteresis of wire cables in Stockbridge dampers , 2002 .
[3] Takeru Igusa,et al. Vibration Control Using Multiple Tuned Mass Dampers , 1994 .
[4] Chi-Chang Lin,et al. Optimum design and experimental study of multiple tuned mass dampers with limited stroke , 2010 .
[5] Chi-Chang Lin,et al. Seismic performance of multiple tuned mass dampers for soil–irregular building interaction systems ☆ , 2005 .
[6] T. T. Soong,et al. Parametric study and simplified design of tuned mass dampers , 1998 .
[7] Matthew Lackner,et al. Offshore Wind Turbine Load Reduction Employing Optimal Passive Tuned Mass Damping Systems , 2013, IEEE Transactions on Control Systems Technology.
[8] M.Q. Feng,et al. Earthquake simulator testing of base-isolated power transformers , 2006, IEEE Transactions on Power Delivery.
[9] Jae-Sung Bae,et al. Vibration Suppression of a Large Beam Structure Using Tuned Mass Damper and Eddy Current Damping , 2014 .
[10] Samir A. Nayfeh,et al. Optimization of the individual stiffness and damping parameters in multiple-tuned-mass damper systems , 2003, SPIE Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.
[11] Q. Xie,et al. Earth, Wind, and Ice , 2011, IEEE Power and Energy Magazine.
[12] A. Filiatrault,et al. Estimation of displacement at interconnection points of substation equipment subjected to earthquakes , 2004, IEEE Transactions on Power Delivery.
[13] S. Okabe,et al. Evaluation of Breakdown Characteristics of Gas Insulated Switchgears for Non-Standard Lightning Impulse Waveforms - Breakdown Characteristics for Non-Standard Lightning Impulse Waveforms Associated with Lightning Surges , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.
[14] Gangbing Song,et al. Seismic Control of Power Transmission Tower Using Pounding TMD , 2013 .
[15] Ronghua Huan,et al. The Effect of High-Frequency Parametric Excitation on a Stochastically Driven Pantograph-Catenary System , 2014 .
[16] M. Ala Saadeghvaziri,et al. On Seismic Response of Substation Equipment and Application of Base Isolation to Transformers , 2010, IEEE Transactions on Power Delivery.
[17] Zheng Lu,et al. Comparison Study of Vibration Control Effects between Suspended Tuned Mass Damper and Particle Damper , 2014 .
[18] H. Rudnick,et al. Lessons from the 2010 Chilean earthquake and its impact on electricity supply , 2010, 2010 International Conference on Power System Technology.
[19] Tan Ping. Study of aseismic performance and damping effects of porcelain column circuit breaker SF6 , 2009 .
[20] Chunxiang Li. Performance of multiple tuned mass dampers for attenuating undesirable oscillations of structures under the ground acceleration , 2000 .
[21] Bo Chen,et al. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations , 2015 .
[22] ZhiQiang Chen,et al. Gearbox Fault Identification and Classification with Convolutional Neural Networks , 2015 .
[23] Guan Zhicheng,et al. Development of composite insulators in China , 1999, IEEE Transactions on Dielectrics and Electrical Insulation.
[24] S. Ersoy,et al. Seismic response of transformer-bushing systems , 2004, IEEE Transactions on Power Delivery.
[25] S. Okabe,et al. Evaluation of breakdown characteristics of gas insulated switchgears for non-standard lightning impulse waveforms - breakdown characteristics under non-uniform electric field , 2008, IEEE Transactions on Dielectrics and Electrical Insulation.
[26] Seth D. Guikema,et al. Post-Earthquake Restoration Planning for Los Angeles Electric Power , 2006 .