Analysis of shielding failure in transmission lines considering both first and subsequent strokes

This work asses the shielding failure of transmission lines by applying the Electrogeometric Model, notably considering the influence of both first and subsequent strokes and also channel angles different from 0° (vertical channel). Considering different tower geometries, it is shown that the shielding failure rate of transmission lines is much more significant for subsequent strokes than for first stroke currents. Furthermore, it is shown that considering channel angles different from 0° leads to an increase of the number of strokes hitting phase conductors. Such increase can be very significant depending on the tower geometry, for instance, in case of EHV double circuit lines.

[1]  Joao Clavio Salari A Methodology for Computing Transmission-Line Short Circuits Caused by Direct and Nearby Ground Lightning Incidence—Part I: Methodological Aspects , 2014, IEEE Transactions on Power Delivery.

[2]  Andre T. Lobato,et al.  Analysis of the cumulative probability distribution of the stroke angle in lightning incidence to three-phase overhead transmission lines , 2013, 2013 International Symposium on Lightning Protection (XII SIPDA).

[3]  E. R. Whitehead,et al.  Field and Analytical Studies of Transmission Line Shielding: Part , 1968 .

[4]  S. Visacro,et al.  Backflashovers of Transmission Lines Due to Subsequent Lightning Strokes , 2012, IEEE Transactions on Electromagnetic Compatibility.

[5]  Zhifeng Li,et al.  Comparison of numerical analysis models for shielding failure of transmission lines , 2013 .

[6]  S. Visacro,et al.  A Class of Hazardous Subsequent Lightning Strokes in Terms of Insulation Stress , 2012, IEEE Transactions on Electromagnetic Compatibility.

[7]  F. Rizk,et al.  Modeling of lightning incidence to tall structures. I. Theory , 1994 .

[8]  Marco Aurélio O. Schroeder,et al.  Statistical analysis of lightning current parameters: Measurements at Morro do Cachimbo Station , 2004 .

[9]  Rong Zeng,et al.  Analysing on characteristics of lightning shielding failure of UHVAC double circuit transmission line based on leader progression method , 2010, 2010 Asia-Pacific International Symposium on Electromagnetic Compatibility.

[10]  K. Berger Parameters of lightning flashes , 1975 .

[11]  E. Garbagnati,et al.  Lightning stroke simulation by means of the leader progression model. I. Description of the model and evaluation of exposure of free-standing structures , 1990 .

[12]  Zhifeng Li,et al.  Comparison of numerical analysis models for shielding failure of transmission lines , 2011, 2011 7th Asia-Pacific International Conference on Lightning.

[13]  Vladimir A. Rakov,et al.  Review of lightning properties from electric field and TV observations , 1994 .