Digital image capture and automated analysis of posterior capsular opacification.

PURPOSE To develop and validate a digital imaging and analysis technique for assessing the extent of posterior capsular opacification after cataract surgery. METHODS Retroillumination images of the posterior capsule were obtained by using a digital camera mounted on a slit lamp. The images were analyzed using an available image analysis software program. The image acquisition and analysis techniques were tested for face validity, reproducibility, and the ability to detect progression of capsular opacity over time. RESULTS Digital retroillumination images were obtained without patient discomfort. Automated analysis of images correlated well with clinical grading both at slit lamp examination and when looking at the images themselves (Spearman's correlation coefficient >0.7). Analysis of images taken at different times showed high reproducibility (intraclass correlation >0.9), and the system was able to identify progression of capsular opacity over a 2-year period with a mean increase of 15.8% in progressors versus an increase of 0.6% in nonprogressors (P < 0.05). CONCLUSIONS Digital retroillumination images of the posterior capsule can be obtained reliably, and automated analyses correlate well with clinical assessment. The system presented here uses commercially available instruments and software, and it is practical for use in longitudinal studies of posterior capsule opacification. It is reliable, easy to use, and can detect small changes in the percentage area covered by posterior capsule opacification over time.

[1]  F Hayashi,et al.  In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery. , 1998, American journal of ophthalmology.

[2]  K Bandeen-Roche,et al.  Function and visual impairment in a population-based study of older adults. The SEE project. Salisbury Eye Evaluation. , 1997, Investigative ophthalmology & visual science.

[3]  N. Powe,et al.  National Outcomes of Cataract Extraction: Retinal Detachment and Endophthalmids after Outpatient Cataract Surgery , 1991 .

[4]  M. A. Vivino,et al.  Reproducibility study of posterior subcapsular opacities on the NEI retroillumination image analysis system , 1994, Eye.

[5]  McIntyre Dj,et al.  Posterior capsule opacification. , 1988 .

[6]  James F. Boyce,et al.  Segmentation of a class of ophthalmological images using a directional variance operator and co-occurrence arrays , 1997 .

[7]  M. Blum,et al.  Photographic image analysis system of posterior capsule opacification , 1997, Journal of cataract and refractive surgery.

[8]  H. Hayashi,et al.  Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. , 1998, Archives of ophthalmology.

[9]  A. Sommer,et al.  National outcomes of cataract extraction. Increased risk of retinal complications associated with Nd:YAG laser capsulotomy. The Cataract Patient Outcomes Research Team. , 1992, Ophthalmology.

[10]  J. Javitt,et al.  Geographic Variation in Utilization of Cataract Surgery , 1995, Medical care.

[11]  Reinhard Klette,et al.  Handbook of image processing operators , 1996 .

[12]  M S Lasa,et al.  Scheimpflug photography and postcataract surgery posterior capsule opacification. , 1995, Ophthalmic surgery.

[13]  Russell L. McCally,et al.  Light Scattering from Cornea and Corneal Transparency , 1990 .

[14]  Barry R. Masters,et al.  Noninvasive Diagnostic Techniques in Ophthalmology , 1990, Springer New York.

[15]  S. Barman,et al.  Relationship between intraocular lens biomaterials and posterior capsule opacification , 1998, Journal of cataract and refractive surgery.

[16]  E. Bass,et al.  Cataract surgical techniques. Preferences and underlying beliefs. , 1995, Archives of ophthalmology.

[17]  N. Powe,et al.  Synthesis of the literature on visual acuity and complications following cataract extraction with intraocular lens implantation. Cataract Patient Outcome Research Team. , 1994, Archives of ophthalmology.

[18]  David J. Spalton,et al.  High‐resolution digital retroillumination imaging of the posterior lens capsule after cataract surgery , 1997, Journal of cataract and refractive surgery.

[19]  John M Sparrow,et al.  The Oxford modular cataract image analysis system , 1990, Eye.

[20]  John C. Russ,et al.  The Image Processing Handbook , 2016, Microscopy and Microanalysis.