A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition

A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition. (May 2011) Reza Muhammad Abdullah, B.Sc., Kwame Nkrumah University of Science & Tech Chair of Advisory Committee: Dr. Edgar Sanchez-Sinencio Biopotential signals are important to physicians for diagnosing medical conditions in patients. Traditionally, biopotentials are acquired using contact electrodes together with instrumentation amplifiers (INAs). The biopotentials are generally weak and in the presence of stronger common mode signals. The INA thus needs to have very good Common Mode Rejection Ratio (CMRR) to amplify the weak biopotential while rejecting the stronger common mode interferers. Opamp based INAs with a resistorcapacitor feedback are suitable for acquiring biopotentials with low power and low noise performance. However, CMRR of such INA topologies is typically very poor. In the presented research, a technique is proposed for improving the CMRR of opamp based INAs in RC feedback configurations by dynamically matching input and feedback capacitor pairs. Two instrumentation amplifiers (one fully differential and the other fully balanced fully symmetric) are designed with the proposed dynamic element matching scheme. Post layout simulation results show that with 1% mismatch between the limiting capacitor pairs, CMRR is improved to above 150dB when the proposed dynamic element matching scheme is used. The INAs draw about 10uA of quiescent current from a 1.5 dual power supply source. The input referred noise of the INAs is less than 3uV/ Hz.

[1]  Reid R. Harrison,et al.  A Versatile Integrated Circuit for the Acquisition of Biopotentials , 2007, 2007 IEEE Custom Integrated Circuits Conference.

[2]  Pieter Rombouts,et al.  A study of dynamic element-matching techniques for 3-level unit elements , 2000 .

[3]  Tobi Delbrück,et al.  Adaptive photoreceptor with wide dynamic range , 1994, Proceedings of IEEE International Symposium on Circuits and Systems - ISCAS '94.

[4]  Kok Lim Chan,et al.  Dynamic Element Matching to Prevent Nonlinear Distortion From Pulse-Shape Mismatches in High-Resolution DACs , 2008, IEEE Journal of Solid-State Circuits.

[5]  Refet Firat Yazicioglu,et al.  A 60 $\mu$W 60 nV/$\surd$Hz Readout Front-End for Portable Biopotential Acquisition Systems , 2007, IEEE Journal of Solid-State Circuits.

[6]  R. R. Harrison,et al.  A low-power low-noise CMOS amplifier for neural recording applications , 2003, IEEE J. Solid State Circuits.

[7]  A. Bakker,et al.  A CMOS nested-chopper instrumentation amplifier with 100-nV offset , 2000, IEEE Journal of Solid-State Circuits.

[8]  Edgar Sanchez-Sinencio,et al.  High-PSRR low-power single supply OTA , 2010 .

[9]  Huikai Xie,et al.  A Low-Power Low-Noise Dual-Chopper Amplifier for Capacitive CMOS-MEMS Accelerometers , 2011, IEEE Sensors Journal.

[10]  W.M.C. Sansen,et al.  A micropower low-noise monolithic instrumentation amplifier for medical purposes , 1987 .

[11]  Refet Firat Yazicioglu,et al.  Biopotential Readout Circuits for Portable Acquisition Systems , 2008 .

[12]  E. Vittoz,et al.  A CMOS Chopper Amplifier , 1986, ESSCIRC '86: Twelfth European Solid-State Circuits Conference.