Inverse dynamics based on occlusion-resistant Kinect data: Is it usable for ergonomics?
暂无分享,去创建一个
Charles Pontonnier | Georges Dumont | Franck Multon | Hubert P. H. Shum | Antoine Muller | Pierre Plantard | F. Multon | A. Muller | C. Pontonnier | G. Dumont | P. Plantard | Pierre Plantard
[1] Stephen Bao,et al. Automation of Workplace Lifting Hazard Assessment for Musculoskeletal Injury Prevention , 2014, Annals of Occupational and Environmental Medicine.
[2] Ettore Pennestrì,et al. Comparison between low-cost marker-less and high-end marker-based motion capture systems for the computer-aided assessment of working ergonomics , 2016, Ergonomics.
[3] Ruzena Bajcsy,et al. Evaluation of upper extremity reachable workspace using Kinect camera. , 2013, Technology and health care : official journal of the European Society for Engineering and Medicine.
[4] J J O'Connor,et al. Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. , 1999, Journal of biomechanics.
[5] B Bonnechère,et al. Determination of the precision and accuracy of morphological measurements using the Kinect™ sensor: comparison with standard stereophotogrammetry , 2014, Ergonomics.
[6] Hartmut Witte,et al. ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion--part I: ankle, hip, and spine. International Society of Biomechanics. , 2002, Journal of biomechanics.
[7] Hartmut Witte,et al. ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion, I: ankle, hip, and spine , 2002 .
[8] Gabriele Bleser,et al. Innovative system for real-time ergonomic feedback in industrial manufacturing. , 2013, Applied ergonomics.
[9] Tilak Dutta,et al. Evaluation of the Kinect™ sensor for 3-D kinematic measurement in the workplace. , 2012, Applied ergonomics.
[10] I Kingma,et al. Force direction and physical load in dynamic pushing and pulling , 2000, Ergonomics.
[11] Jinxiang Chai,et al. Accurate realtime full-body motion capture using a single depth camera , 2012, ACM Trans. Graph..
[12] M. McCall,et al. Rigid Body Dynamics , 2008 .
[13] Hubert P. H. Shum,et al. Real-Time Posture Reconstruction for Microsoft Kinect , 2013, IEEE Transactions on Cybernetics.
[14] Fouad Bennis,et al. A new simple dynamic muscle fatigue model and its validation , 2022, ArXiv.
[15] Franck Multon,et al. Detection of gait cycles in treadmill walking using a Kinect. , 2015, Gait & posture.
[16] Franck Multon,et al. Filtered pose graph for efficient kinect pose reconstruction , 2016, Multimedia Tools and Applications.
[17] Georges Dumont,et al. Strengths and limitations of a musculoskeletal model for an analysis of simulated meat cutting tasks. , 2014, Applied ergonomics.
[18] R. Riemer,et al. Uncertainties in inverse dynamics solutions: a comprehensive analysis and an application to gait. , 2008, Gait & posture.
[19] L McAtamney,et al. RULA: a survey method for the investigation of work-related upper limb disorders. , 1993, Applied ergonomics.
[20] Franck Multon,et al. New Lower-Limb Gait Asymmetry Indices Based on a Depth Camera , 2015, Sensors.
[21] Bryan Buchholz,et al. ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand. , 2005, Journal of biomechanics.
[22] Charles Pontonnier,et al. Uncertainty propagation in multibody human model dynamics , 2017, Multibody System Dynamics.
[23] A. Muller,et al. A Simple Method to Calibrate Kinematical Invariants: Application to Overhead Throwing , 2015 .
[24] Shmuel Springer,et al. Validity of the Kinect for Gait Assessment: A Focused Review , 2016, Sensors.
[25] Andrew W. Fitzgibbon,et al. Real-time human pose recognition in parts from single depth images , 2011, CVPR 2011.
[26] Franck Multon,et al. Pose Estimation with a Kinect for Ergonomic Studies: Evaluation of the Accuracy Using a Virtual Mannequin , 2015, Sensors.
[27] Derek Nowrouzezahrai,et al. Learning hatching for pen-and-ink illustration of surfaces , 2012, TOGS.
[28] Franck Multon,et al. Validation of an ergonomic assessment method using Kinect data in real workplace conditions. , 2017, Applied ergonomics.
[29] Gentiane Venture,et al. Fast Determination of the Planar Body Segment Inertial Parameters Using Affordable Sensors , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.
[30] Michael Damsgaard,et al. AnyBody - a software system for ergonomic optimization , 2003 .
[31] Ruzena Bajcsy,et al. Evaluation of Pose Tracking Accuracy in the First and Second Generations of Microsoft Kinect , 2015, 2015 International Conference on Healthcare Informatics.
[32] L. Chèze,et al. Adjustments to McConville et al. and Young et al. body segment inertial parameters. , 2007, Journal of biomechanics.
[33] Roy Featherstone,et al. Rigid Body Dynamics Algorithms , 2007 .
[34] Jose Antonio Diego-Mas,et al. Using Kinect™ sensor in observational methods for assessing postures at work. , 2014, Applied ergonomics.
[35] Baining Guo,et al. Exemplar-Based Human Action Pose Correction , 2014, IEEE Transactions on Cybernetics.
[36] Marjorie Skubic,et al. Fall Detection in Homes of Older Adults Using the Microsoft Kinect , 2015, IEEE Journal of Biomedical and Health Informatics.
[37] A Muller,et al. Dealing with modularity of multibody models , 2015, Computer methods in biomechanics and biomedical engineering.
[38] M. Damsgaard,et al. Fifth World Congress on Structural and Multidisciplinary Optimization. Lido di Jesolo - Venice, Italy, May 19-23, 2003. , 2003 .
[39] John M. Hollerbach,et al. Dynamic interactions between limb segments during planar arm movement , 1982, Biological Cybernetics.
[40] Michael Damsgaard,et al. Analysis of musculoskeletal systems in the AnyBody Modeling System , 2006, Simul. Model. Pract. Theory.
[41] Shrawan Kumar,et al. Working Postures: A Literature Review , 2004, Journal of Occupational Rehabilitation.
[42] Stepán Obdrzálek,et al. Accuracy and robustness of Kinect pose estimation in the context of coaching of elderly population , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.
[43] Gentiane Venture,et al. An individual and dynamic Body Segment Inertial Parameter validation method using ground reaction forces. , 2014, Journal of biomechanics.
[44] C. C. Martin,et al. A real-time ergonomic monitoring system using the Microsoft Kinect , 2012, 2012 IEEE Systems and Information Engineering Design Symposium.
[45] Kelly J. Bower,et al. Concurrent validity of the Microsoft Kinect for assessment of spatiotemporal gait variables. , 2013, Journal of biomechanics.