Saturation of Current Transformers and its Impact on Digital Overcurrent Relays

Improper selections of current transformers will result in CT's saturation during fault conditions which can affect protection relays operations. With the absence of clear and practical guidelines for CT's selections, designers are facing great difficulties to ensure proper operations of digital relays. The impact of CT saturation is different for different protection devices and schemes. This paper investigates the influence of CT saturation on over-current digital relays, in distribution systems where loads are relatively small and connected to switch-gears with high short circuit levels. A research was performed to verify the operations of instantaneous and time-delayed over-current digital relays to ensure coordination with other devices and safe isolations of faults. It is shown that instantaneous digital relays will perform properly with a relatively small CT's. A criterion for selecting CT's for instantaneous digital over-current relays operations is presented. However, time-delayed over-current relays will be significantly impacted by CT's saturation and special care shall be taken to achieve coordination with other devices

[1]  Lj.A. Kojovic Guidelines for current transformers selection for protection systems , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[2]  S.E. Zocholl,et al.  Primary high-current testing of relays with low ratio current transformers , 2004, 57th Annual Conference for Protective Relay Engineers, 2004.

[3]  Arun G. Phadke,et al.  Protection system representation in the Electromagnetic Transients Program , 1994 .

[4]  F. de Leon,et al.  A simple representation of dynamic hysteresis losses in power transformers , 1995 .

[5]  S.E. Zocholl,et al.  Effect of waveform distortion on protective relays , 1991, Conference Record of the 1991 IEEE Industry Applications Society Annual Meeting.

[6]  Lj.A. Kojovic Comparison of different current transformer modeling techniques for protection system studies , 2002, IEEE Power Engineering Society Summer Meeting,.

[7]  Walter Elmore,et al.  Protective Relaying Theory And Applications , 1994 .

[8]  Norman T. Stringer The effect of DC offset on current operated relays , 1997, 1997 IEEE Industrial and Commercial Power Systems Technical Conference. Conference Record.

[9]  Peter Crossley,et al.  Compensation of the distortion in the secondary current caused by saturation and remanence in a CT , 2004 .

[10]  Chul-Hwan Kim,et al.  Educational use of EMTP MODELS for the study of a distance relaying algorithm for protecting transmission lines , 2000 .

[11]  Gilbert Sybille,et al.  Hysteresis modeling in the MATLAB/Power System Blockset , 2003, Math. Comput. Simul..

[12]  H. W. Dommel,et al.  On modelling iron core nonlinearities , 1993 .

[13]  Jiuping Pan,et al.  An efficient compensation algorithm for current transformer saturation effects , 2004 .

[14]  D. W. Ackermann Current transformer measurements of distorted current waveforms with secondary load impedance , 1999, 1999 IEEE Africon. 5th Africon Conference in Africa (Cat. No.99CH36342).

[15]  P. E. Sutherland Applying CTs with digital ground relays , 2001 .

[16]  S.E. Zocholl,et al.  Relay performance considerations with low ratio CTS and high fault currents , 1993, Conference Record Industrial and Commercial Power Systems Technical Conference 1993.

[17]  Baldwin Bridger,et al.  Operation of ground sensor relays under conditions of partial CT saturation , 1996, IAS '96. Conference Record of the 1996 IEEE Industry Applications Conference Thirty-First IAS Annual Meeting.

[18]  J. Lewis Blackburn,et al.  Protective Relaying: Principles And Applications , 2006 .

[19]  Cheng Li-jun The research of the sampling method for CT saturation for numerical busbar protection , 2004 .

[20]  Ali Abur,et al.  Experimental evaluation of EMTP-based current transformer models for protective relay transient study , 1994 .

[21]  J. Mati,et al.  Current Transformers and Coupling-Capacitor Voltage Transformers in Real-Time Simulations , 1997, IEEE Power Engineering Review.

[22]  Mladen Kezunovic,et al.  Mathematical models for current, voltage, and coupling capacitor voltage transformers , 2000 .

[23]  P. R. Drum,et al.  C37.110 guide for the application of current transformers used for protective relaying purposes , 1999 .

[24]  Sergio Bittanti,et al.  Compensation of nonlinearities in a current transformer for the reconstruction of the primary current , 2001, IEEE Trans. Control. Syst. Technol..

[25]  Zia A. Yamayee,et al.  Electromechanical Energy Devices and Power Systems , 1993 .

[26]  Peter Crossley,et al.  Design and evaluation of an algorithm for detecting current transformer saturation , 2004 .

[27]  Lj.A. Kojovic Impact of current transformer saturation on overcurrent protection operation , 2002, IEEE Power Engineering Society Summer Meeting,.