Ion suppression effect in desorption electrospray ionization and electrospray ionization mass spectrometry.

RATIONALE Although it is claimed that desorption electrospray ionization (DESI) causes less ion suppression effects than electrospray ionization (ESI), a related investigation with quantification measurement of ion suppression effects is absent. Herein, a comparative analysis of ion suppression effects between DESI and ESI was conducted, with the aiming of quantitatively studying the ion suppression effect. METHODS CTVA mixtures, a constant concentration of tioconazole with varied concentrations of atenolol, were analyzed by ESI and DESI. The ion suppression effect was characterized by the signal loss of tioconazole in the mixture compared to the signal intensity of tioconazole without interference (denoted as (Isingle - Imixture )/Isingle ). According to the variations in the experimental conditions (such as flow rate, solvent composition, substrate material, capillary inner diameter, sheath gas velocity), ion suppression effects in DESI and ESI were compared. RESULTS With the increasing flow rate, the ion suppression effect in DESI became weaker, while the opposite trend was obtained for ESI. As for capillary inner diameter, a smaller inner diameter resulted in weaker ion suppression effects in DESI and ESI. The solvent composition affected the ion suppression effect, and the PTFE substrate presented the weakest ion suppression effect among the five substrate materials. CONCLUSIONS Though the ion suppression effect in DESI and ESI was shown to relate to experimental conditions, DESI had less effect than ESI under the same experimental conditions in most cases. Moreover, DESI displayed stronger matrix-tolerant ability than ESI which is also attributed to the weaker ion suppression effect.

[1]  R. Cooks,et al.  Internal energy distributions in desorption electrospray ionization (DESI) , 2008, Journal of the American Society for Mass Spectrometry.

[2]  P. Kebarle,et al.  Dependence of ion intensity in electrospray mass spectrometry on the concentration of the analytes in the electrosprayed solution , 1993 .

[3]  A. Furey,et al.  Ion suppression; a critical review on causes, evaluation, prevention and applications. , 2013, Talanta.

[4]  J. V. Iribarne,et al.  On the evaporation of small ions from charged droplets , 1976 .

[5]  T. Veenstra Electrospray ionization mass spectrometry in the study of biomolecular non-covalent interactions. , 1999, Biophysical chemistry.

[6]  N. Manicke,et al.  Ionization Suppression and Recovery in Direct Biofluid Analysis Using Paper Spray Mass Spectrometry , 2016, Journal of The American Society for Mass Spectrometry.

[7]  Quantitative measurements of small molecule mixtures using laser electrospray mass spectrometry. , 2013, Analytical chemistry.

[8]  C. Enke,et al.  A predictive model for matrix and analyte effects in electrospray ionization of singly-charged ionic analytes. , 1997, Analytical chemistry.

[9]  R. Cooks,et al.  Mass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization , 2004, Science.

[10]  C. Enke,et al.  Effects of salt concentration on analyte response using electrospray ionization mass spectrometry , 1999, Journal of the American Society for Mass Spectrometry.

[11]  Paul M. Flanigan,et al.  Laser electrospray mass spectrometry minimizes ion suppression facilitating quantitative mass spectral response for multicomponent mixtures of proteins. , 2013, Analytical chemistry.

[12]  F. Basile,et al.  Desorption electrospray ionization-mass spectrometry of proteins. , 2007, Analytical chemistry.

[13]  V. Havlíček,et al.  Ion internal energy, salt tolerance and a new technical improvement of desorption nanoelectrospray. , 2014, Journal of mass spectrometry : JMS.

[14]  R. Cooks,et al.  Rapid screening of anabolic steroids in urine by reactive desorption electrospray ionization. , 2007, Analytical chemistry.

[15]  Robert L. White,et al.  Improved partition equilibrium model for predicting analyte response in electrospray ionization mass spectrometry. , 2009, Journal of mass spectrometry : JMS.

[16]  R. Cooks,et al.  Salt tolerance of desorption electrospray ionization (DESI) , 2007, Journal of the American Society for Mass Spectrometry.

[17]  J. V. Iribarne,et al.  Field induced ion evaporation from liquid surfaces at atmospheric pressure , 1979 .

[18]  J. Fenn,et al.  Electrospray interface for liquid chromatographs and mass spectrometers. , 1985, Analytical chemistry.

[19]  J. V. Iribarne,et al.  Atmospheric pressure ion evaporation-mass spectrometry , 1983 .

[20]  Z. Takáts,et al.  Analysis of biological fluids by direct combination of solid phase extraction and desorption electrospray ionization mass spectrometry. , 2009, Analytical chemistry.

[21]  Jack D. Henion,et al.  Ion spray interface for combined liquid chromatography/atmospheric pressure ionization mass spectrometry , 1987 .

[22]  R. Cooks,et al.  Desorption electrospray ionization mass spectrometry for the analysis of pharmaceuticals and metabolites. , 2006, Rapid communications in mass spectrometry : RCM.

[23]  P. Kebarle,et al.  Effect of the conductivity of the electrosprayed solution on the electrospray current. Factors determining analyte sensitivity in electrospray mass spectrometry , 1991 .

[24]  J. Fenn,et al.  Electrospray ion source: another variation on the free-jet theme , 1984 .

[25]  R. Cody,et al.  Versatile new ion source for the analysis of materials in open air under ambient conditions. , 2005, Analytical chemistry.