Reproducibility of the external surface position in left‐breast DIBH radiotherapy with spirometer‐based monitoring

Deep inspiration breath hold (DIBH) in left‐sided breast cancer radiotherapy treatments allows for a reduction in cardiac and pulmonary doses without compromising target coverage. The selection of the most appropriate technology for DIBH monitoring is a crucial issue. We evaluated the stability and reproducibility of DIBHs controlled by a spirometric device, by assessing the variability of the external surface position within a single DIBH (intra‐DIBH) and between DIBHs performed in the same treatment session (intrafraction) or in different sessions (interfraction). The study included seven left‐breast cancer patients treated with spirometer‐based DIBH radiotherapy. Infrared optical tracking was used to record the 3D coordinates of seven to eleven passive markers placed on the patient's thoraco‐abdominal surface during 29‐43 DIBHs performed in six to eight treatment sessions. The obtained results showed displacements of the external surface between different sessions up to 6.3 mm along a single direction, even at constant inspired volumes. The median value of the interfraction variability in the position of breast passive markers was 2.9 mm (range 1.9‐4.8 mm) in the latero‐lateral direction, 3.6 mm (range 2.2‐4.6 mm) in the antero‐posterior direction, and 4.3 mm (range 2.8‐6.2 mm) in the cranio‐caudal direction. There were no significant dose distribution variations for target and organs at risk with respect to the treatment plan, confirming the adequacy of the applied clinical margins (15 mm) to compensate for the measured setup uncertainties. This study demonstrates that spirometer‐based control does not guarantee a stable and reproducible position of the external surface in left‐breast DIBH radiotherapy, suggesting the need for more robust DIBH monitoring techniques when reduced margins and setup uncertainties are required for improving normal tissue sparing and decreasing cardiac and pulmonary toxicity. PACS number: 87.55.Km

[1]  David Sarrut,et al.  Multi-dimensional respiratory motion tracking from markerless optical surface imaging based on deformable mesh registration , 2012, Physics in medicine and biology.

[2]  Marcel van Herk,et al.  Errors and margins in radiotherapy. , 2004, Seminars in radiation oncology.

[3]  Markus Stock,et al.  Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking. , 2006, Medical physics.

[4]  Victy Y W Wong,et al.  Real-time monitoring and control on deep inspiration breath-hold for lung cancer radiotherapy-Combination of ABC and external marker tracking. , 2010, Medical physics.

[5]  A. Pedotti,et al.  Compartmental Analysis of Breathing in the Supine and Prone Positions by Optoelectronic Plethysmography , 2004, Annals of Biomedical Engineering.

[6]  G Ferrigno,et al.  Self-marking of anatomical landmarks for on-orbit experimental motion analysis compared to expert direct-marking. , 2002, Human movement science.

[7]  G. Sharp,et al.  A voluntary breath-hold treatment technique for the left breast with unfavorable cardiac anatomy using surface imaging. , 2012, International journal of radiation oncology, biology, physics.

[8]  James M Balter,et al.  Respiratory motion of the heart and positional reproducibility under active breathing control. , 2007, International journal of radiation oncology, biology, physics.

[9]  Steve B. Jiang,et al.  Using surface imaging and visual coaching to improve the reproducibility and stability of deep-inspiration breath hold for left-breast-cancer radiotherapy , 2009, Physics in medicine and biology.

[10]  Cristina Garibaldi,et al.  Dosimetric effects within target and organs at risk of interfractional patient mispositioning in left breast cancer radiotherapy. , 2004, International journal of radiation oncology, biology, physics.

[11]  Jan-Jakob Sonke,et al.  Accuracy evaluation of a 3-dimensional surface imaging system for guidance in deep-inspiration breath-hold radiation therapy. , 2013, International journal of radiation oncology, biology, physics.

[12]  B. Poppe,et al.  Introduction of a Breath Gating System in a Clinical Environment , 2009 .

[13]  A. Recht Which breast cancer patients should really worry about radiation-induced heart disease--and how much? , 2006, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[14]  Hiroshi Honda,et al.  Reproducibility of the abdominal and chest wall position by voluntary breath-hold technique using a laser-based monitoring and visual feedback system. , 2007, International journal of radiation oncology, biology, physics.

[15]  H. Nawashiro,et al.  Light scattering signal as an indicator of loss of tissue viability in brains: Experiments using rat hypoxia models , 2009 .

[16]  VV, a 4D slicer , 2012 .

[17]  I. Mjaaland,et al.  Cardiac and pulmonary dose reduction for tangentially irradiated breast cancer, utilizing deep inspiration breath-hold with audio-visual guidance, without compromising target coverage , 2011, Acta oncologica.

[18]  James M Balter,et al.  Short-term displacement and reproducibility of the breast and nodal targets under active breathing control. , 2007, International journal of radiation oncology, biology, physics.

[19]  P. Remeijer,et al.  Estimation of heart-position variability in 3D-surface-image-guided deep-inspiration breath-hold radiation therapy for left-sided breast cancer. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[20]  Di Yan,et al.  Three-dimensional evaluation of intra- and interfraction immobilization of lung and chest wall using active breathing control: a reproducibility study with breast cancer patients. , 2003, International journal of radiation oncology, biology, physics.

[21]  C. Ling,et al.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. , 2000, International journal of radiation oncology, biology, physics.

[22]  Cristina Garibaldi,et al.  Integration of Enhanced Optical Tracking Techniques and Imaging in IGRT. , 2007, Journal of radiation research.

[23]  A. Appelt,et al.  Improved heart, lung and target dose with deep inspiration breath hold in a large clinical series of breast cancer patients. , 2012, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[24]  Michael B Sharpe,et al.  Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. , 2003, International journal of radiation oncology, biology, physics.

[25]  R. Collins,et al.  Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trials , 2005, The Lancet.

[26]  David Djajaputra,et al.  Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer. , 2004, Medical physics.

[27]  H. M. Karara,et al.  Direct Linear Transformation from Comparator Coordinates into Object Space Coordinates in Close-Range Photogrammetry , 2015 .

[28]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[29]  Cristina Garibaldi,et al.  Patient set-up verification by infrared optical localization and body surface sensing in breast radiation therapy. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[30]  Jan-Jakob Sonke,et al.  Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imaging. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[31]  W. Curran,et al.  OT2-06-02: A Randomized Phase III Study of Conventional Whole Breast Irradiation (WBI) vs Partial Breast Irradiation (PBI) for Women with Stage 0, 1, or 2 Breast Cancer: NSABP B-39/RTOG 0413. , 2011 .