Full-field transient vibrometry of the human tympanic membrane by local phase correlation and high-speed holography

Abstract. Understanding the human hearing process would be helped by quantification of the transient mechanical response of the human ear, including the human tympanic membrane (TM or eardrum). We propose a new hybrid high-speed holographic system (HHS) for acquisition and quantification of the full-field nanometer transient (i.e., >10  kHz) displacement of the human TM. We have optimized and implemented a 2+1 frame local correlation (LC) based phase sampling method in combination with a high-speed (i.e., >40  K fps) camera acquisition system. To our knowledge, there is currently no existing system that provides such capabilities for the study of the human TM. The LC sampling method has a displacement difference of <11  nm relative to measurements obtained by a four-phase step algorithm. Comparisons between our high-speed acquisition system and a laser Doppler vibrometer indicate differences of <10  μs. The high temporal (i.e., >40  kHz) and spatial (i.e., >100  k data points) resolution of our HHS enables parallel measurements of all points on the surface of the TM, which allows quantification of spatially dependent motion parameters, such as modal frequencies and acoustic delays. Such capabilities could allow inferring local material properties across the surface of the TM.

[1]  Jeffrey Cheng,et al.  Automatic Acquisition and Processing of Large Sets of Holographic Measurements in Medical Research , 2011 .

[2]  John J. Rosowski,et al.  Digital holographic measurements of shape and three-dimensional sound-induced displacements of tympanic membrane , 2013 .

[3]  John J. Rosowski,et al.  Measurements of three-dimensional shape and sound-induced motion of the chinchilla tympanic membrane , 2013, Hearing Research.

[4]  Yôiti Suzuki,et al.  Equal-loudness-level contours for pure tones. , 2004, The Journal of the Acoustical Society of America.

[5]  Giancarlo Pedrini,et al.  Transient vibration measurements using multi-pulse digital holography , 1998 .

[6]  Sunil Puria,et al.  Middle-ear circuit model parameters based on a population of human ears. , 2008, The Journal of the Acoustical Society of America.

[7]  J. Allen,et al.  Measurements and model of the cat middle ear: evidence of tympanic membrane acoustic delay. , 1998, The Journal of the Acoustical Society of America.

[8]  Wolfgang Osten,et al.  High-speed digital holographic interferometry for vibration measurement. , 2006, Applied optics.

[9]  Cosme Furlong,et al.  Digital holographic measurements of shape and 3D sound-induced displacements of Tympanic Membrane. , 2013, Optical engineering.

[10]  J. Rosowski,et al.  An Overview of Wideband Immittance Measurements Techniques and Terminology: You Say Absorbance, I Say Reflectance , 2013, Ear and hearing.

[11]  John J. Rosowski,et al.  Implementation and Evaluation of Single Frame Recording Techniques for Holographic Measurements of the Tympanic Membrane In-Vivo , 2014 .

[12]  K A Stetson,et al.  Fourier-transform evaluation of phase data in spatially phase-biased TV holograms. , 1996, Applied optics.

[13]  C. Wykes,et al.  Holographic and Speckle Interferometry: A Discussion of the Theory, Practice and Application of the Techniques , 1983 .

[14]  Cosme Furlong,et al.  Long-Term Effects of Cyclic Environmental Conditions on Paintings in Museum Exhibition by Laser Shearography , 2014 .

[15]  Terry Yuan-Fang Chen,et al.  An instantaneous phase shifting ESPI system for dynamic deformation measurement , 2011 .

[16]  Xiangming Zhang,et al.  Dynamic properties of human tympanic membrane – experimental measurement and modelling analysis , 2010 .

[17]  J R Johnstone,et al.  Basilar membrane and middle-ear vibration in guinea pig measured by capacitive probe. , 1975, The Journal of the Acoustical Society of America.

[18]  Cosme Furlong,et al.  HIGH-SPEED DIGITAL HOLOGRAPHIC METHODS TO CHARACTERIZE THE TRANSIENT ACOUSTO-MECHANICAL RESPONSE OF HUMAN TM , 2013 .

[19]  D. Schmitt,et al.  Optimization of fringe pattern calculation with direct correlations in speckle interferometry. , 1997, Applied optics.

[20]  Matt Novak,et al.  Analysis of a micropolarizer array-based simultaneous phase-shifting interferometer. , 2005, Applied optics.

[21]  John J. Rosowski,et al.  High-speed holographic system for full-field transient vibrometry of the human tympanic membrane , 2014, Optics & Photonics - Optical Engineering + Applications.

[22]  Gary S. Schajer,et al.  Modulo-2pi phase determination from individual ESPI images , 2012 .

[23]  D. Kemp Stimulated acoustic emissions from within the human auditory system. , 1978, The Journal of the Acoustical Society of America.

[24]  Sunil Puria,et al.  Measurements of human middle ear forward and reverse acoustics: implications for otoacoustic emissions. , 2003, The Journal of the Acoustical Society of America.

[25]  John J. Rosowski,et al.  Computer-assisted time-averaged holograms of the motion of the surface of the mammalian tympanic membrane with sound stimuli of 0.4–25kHz , 2009, Hearing Research.

[26]  S. Merchant,et al.  Motion of the surface of the human tympanic membrane measured with stroboscopic holography , 2010, Hearing Research.

[27]  S. Merchant,et al.  Wave motion on the surface of the human tympanic membrane: holographic measurement and modeling analysis. , 2013, The Journal of the Acoustical Society of America.

[28]  J. Buytaert,et al.  Full-Field Thickness Distribution of Human Tympanic Membrane Obtained with Optical Coherence Tomography , 2013, Journal of the Association for Research in Otolaryngology.

[29]  Nikhil D Bapat,et al.  Development of Sound Presentation System (SPS) for Characterization of Sound Induced Displacements in Tympanic Membranes , 2011 .

[30]  James L. Flanagan,et al.  Digital coding of speech in sub-bands , 1976, The Bell System Technical Journal.