A prototype of a new noninvasive device to detect nocturnal hypoglycemia in adolescents with type 1 diabetes--a pilot study.

BACKGROUND Severe hypoglycemic events are a major consequence of tight diabetes control. Continuous glucose monitoring systems (CGMSs) were recently introduced in order to minimize the risk of hypoglycemia. However, the present CGMSs are invasive and costly and have been recently demonstrated to be intolerant for most children and adolescents. Hence there is a need for a simple, noninvasive, convenient, and inexpensive device to detect hypoglycemic events. The Gili Medical Hypoglycemia Non Invasive Monitoring System (GMHNIMS) (Gili Medical Ltd., Migdal HaEmek, Israel) has been currently developed for these purposes. SUBJECTS AND METHODS Ten patients 14-18 years old with type 1 diabetes for at least 1 year participated in a pilot study that was held at the Meyer Children's Hospital, Rambam Medical Center, Haifa, Israel. All patients were either treated by insulin pump or by multiple daily injections. The GMHNIMS was connected to the study subjects during three consecutive nights in an inpatient setting while they received their usual insulin regimen. The system is composed of four sensors (heart rate, perspiration, skin temperature, and tremor) that detect physiologic changes during hypoglycemia. In addition, each patient was connected to a real-time CGMS for 3 nights. When a hypoglycemic event was suspected clinically by the patient, a bedside capillary glucose was checked by a glucometer. RESULTS The system was found to be convenient without any disturbances to sleep quality. The sensitivity of the GMHNIMS for detection of true hypoglycemic events was 100% with specificity of 85.7%. CONCLUSIONS The new device showed high detection rates of nocturnal hypoglycemic events with an acceptable degree of false-positive readings. Being inexpensive and noninvasive, this device has the potential for routine use in insulin-treated patients.

[1]  S. Shalitin,et al.  Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs continuous subcutaneous insulin infusion. , 2004, Archives of pediatrics & adolescent medicine.

[2]  Sonia Caprio,et al.  Do sensor glucose levels accurately predict plasma glucose concentrations during hypoglycemia and hyperinsulinemia? , 2002, Diabetes care.

[3]  Michael O'Grady,et al.  Continuous glucose monitoring and intensive treatment of type 1 diabetes. , 2008, The New England journal of medicine.

[4]  D. Klonoff,et al.  Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline. , 2011, The Journal of clinical endocrinology and metabolism.

[5]  M. Liebert The accuracy of the Guardian RT continuous glucose monitor in children with type 1 diabetes. , 2008, Diabetes technology & therapeutics.

[6]  Nejhdeh Ghevondian,et al.  Clinical Evaluation of a Noninvasive Alarm System for Nocturnal Hypoglycemia , 2010, Journal of diabetes science and technology.

[7]  P. Cryer,et al.  Hypoglycemia in diabetes. , 2003, Diabetes care.

[8]  H. Chase,et al.  Use of the GlucoWatch biographer in children with type 1 diabetes. , 2003, Pediatrics.

[9]  Howard Zisser,et al.  Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. , 2006, Diabetes care.

[10]  H. Nguyen,et al.  Detection of nocturnal hypoglycemic episodes (natural occurrence) in children with Type 1 diabetes using an optimal Bayesian neural network algorithm , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[11]  Howard Wolpert,et al.  Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group. The effect of continuous glucose monitoring in well-controlled type 1 diabetes , 2009 .

[12]  W. Tamborlane,et al.  Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes. , 2001, Diabetes care.

[13]  F. Ovalle,et al.  Continuous Glucose Monitoring and Intensive Treatment of Type 1 Diabetes , 2009 .

[14]  J L Botha,et al.  The British Diabetic Association Cohort Study, I: all‐cause mortality in patients with insulin‐treated diabetes mellitus , 1999, Diabetic medicine : a journal of the British Diabetic Association.

[15]  M. Fisher,et al.  Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) , 2007 .

[16]  Epidemiology of severe hypoglycemia in the diabetes control and complications trial. The DCCT Research Group. , 1991, The American journal of medicine.

[17]  R. Newton,et al.  How Have Patients Reacted to the Implications of the DCCT? , 1996, Diabetes Care.

[18]  P. Czernichow,et al.  Nocturnal hypoglycemia in children and adolescents with insulin-dependent diabetes mellitus: prevalence and risk factors. , 1997, The Journal of pediatrics.

[19]  Satisfaction with continuous glucose monitoring in adults and youths with Type 1 diabetes , 2011, Diabetic medicine : a journal of the British Diabetic Association.

[20]  K. A. Hansen,et al.  Teledyne Sleep Sentry: Evaluation in Pediatric Patients for Detection of Nocturnal Hypoglycemia , 1983, Diabetes Care.

[21]  G. Moneta,et al.  Intensive Diabetes Treatment and Cardiovascular Disease in Patients with Type 1 Diabetes , 2007 .

[22]  R. Brazg,et al.  Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System , 2007, Diabetes Care.

[23]  Motor activity during asymptomatic nocturnal hypoglycemia in adolescents with type 1 diabetes mellitus , 2004, Acta Diabetologica.

[24]  R. Beck,et al.  Diabetes Research in Children Network: Availability of Protocol Data Sets , 2007, Journal of diabetes science and technology.

[25]  P. Cryer,et al.  Hypoglycemia in IDDM , 1989, Diabetes.