Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms.

PURPOSE To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. METHODS AND MATERIALS Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. RESULTS The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left-right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. CONCLUSIONS The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

[1]  J. Fowler,et al.  CyberKnife radiosurgery for stage I lung cancer: results at 36 months. , 2007, Clinical lung cancer.

[2]  Huanmei Wu,et al.  Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system. , 2011, Medical physics.

[3]  M. Lodge,et al.  Stereotactic radiotherapy (SABR) for the treatment of primary non-small cell lung cancer; systematic review and comparison with a surgical cohort. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  Steve Webb,et al.  Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: an experimental study. , 2008, Medical physics.

[5]  Byungchul Cho,et al.  Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT , 2014 .

[6]  F. Banovac,et al.  Radical stereotactic radiosurgery with real-time tumor motion tracking in the treatment of small peripheral lung tumors , 2007, Radiation oncology.

[7]  Koichi Yamazaki,et al.  Insertion and fixation of fiducial markers for setup and tracking of lung tumors in radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[8]  P C Levendag,et al.  Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results , 2006, Acta oncologica.

[9]  Achim Schweikard,et al.  Respiration tracking in radiosurgery. , 2004, Medical physics.

[10]  J. Adler,et al.  Robotic Motion Compensation for Respiratory Movement during Radiosurgery , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[11]  C. Maurer,et al.  Xsight Lung Tracking System: A Fiducial-Less Method for Respiratory Motion Tracking , 2007 .

[12]  M. Hoogeman,et al.  Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files. , 2009, International journal of radiation oncology, biology, physics.

[13]  M. Reiser,et al.  CT fluoroscopy-guided percutaneous fiducial marker placement for CyberKnife stereotactic radiosurgery: technical results and complications in 222 consecutive procedures. , 2014, Journal of vascular and interventional radiology : JVIR.

[14]  R. V. van Klaveren,et al.  Stereotactic radiotherapy with real-time tumor tracking for non-small cell lung cancer: clinical outcome. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[15]  Hiroki Shirato,et al.  Accuracy of tumor motion compensation algorithm from a robotic respiratory tracking system: a simulation study. , 2007, Medical physics.

[16]  Thomas Lacornerie,et al.  Image-Guided Robotic Stereotactic Radiation Therapy with Fiducial-Free Tumor Tracking for Lung Cancer , 2012, Radiation oncology.