Mechanical performances of elastomers used in diffusers

The use of elastomeric diffusers (EDs) has grown together with the expansion of home care. In these devices, the fill volume of the drug reservoir and the flow rate are preset and cannot be modified. The elastomer, which makes up the reservoir walls, is what makes the infusate flow due to the pressure it exerts. The purpose of this work was to quantify, under standardized experimental conditions and following recommended conditions of use, the mechanical performances of the 2 commonly used elastomers (silicone and polyisoprene) and their impact on infusion flow rate consistency. Results show that they exhibit different mechanical performances which leads to concerns regarding the use of these devices for some intravenous (IV) therapies.

[1]  X. Capdevila,et al.  Continuous post-operative regional analgesia at home. , 2001, Minerva anestesiologica.

[2]  J. Heath,et al.  Utilization of an elastomeric continuous infusion device to maintain catheter patency. , 2001, Journal of intravenous nursing : the official publication of the Intravenous Nurses Society.

[3]  X. Capdevila,et al.  Patient-controlled perineural analgesia after ambulatory orthopedic surgery: a comparison of electronic versus elastomeric pumps. , 2003, Anesthesia and analgesia.

[4]  D. Crivellari,et al.  Fourteen-Day Infusion of Ifosfamide in the Management of Advanced Breast Cancer Refractory to Protracted Continuous Infusion of 5-Fluorouracil , 2001, Tumori.

[5]  F. Mccool,et al.  Global physiology and pathophysiology of cough: ACCP evidence-based clinical practice guidelines. , 2006, Chest.

[6]  D. Asiimwe,et al.  Performance of selected flow-restricting infusion devices. , 1998, American journal of health-system pharmacy : AJHP : official journal of the American Society of Health-System Pharmacists.

[7]  D. Crivellari,et al.  Combination chemotherapy with navelbine and continuous infusion of 5-fluorouracil in metastatic, chemotherapy refractory breast cancer. , 2000, Annals of oncology : official journal of the European Society for Medical Oncology.

[8]  P. Denormandie,et al.  Outpatient parenteral antimicrobial therapy (OPAT) for the treatment of osteomyelitis: evaluation of efficacy, tolerance and cost , 2001, Journal of clinical pharmacy and therapeutics.

[9]  P. Bonnabry,et al.  Evaluation of the design and reliability of three elastomeric and one mechanical infusers , 2007, Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners.

[10]  Francis Remerand,et al.  Elastomeric Pump Reliability in Postoperative Regional Anesthesia: A Survey of 430 Consecutive Devices , 2008, Anesthesia and analgesia.

[11]  Dominique Thiveaud,et al.  Industry Science Sponsored Section COMPARISON OF THE PERFORMANCE OF FOUR ELASTOMERIC DEVICES , 2005 .