Abstract A pnCCD is a special type of charge-coupled device developed for spectroscopy and imaging of X-rays with high time resolution and quantum efficiency. Its most famous application is the operation on the XMM-Newton satellite, an X-ray astronomy mission that was launched by the European space agency in 1999. The excellent performance of the focal plane camera has been maintained for more than 6 years in orbit. The energy resolution in particular has shown hardly any degradation since launch. In order to satisfy the requirements of future X-ray astronomy missions as well as those of ground-based experiments, a new type of pnCCD has been developed. This ‘frame-store pnCCD’ shows an enhanced performance compared to the XMM-Newton type of pnCCD. Now, more options in device design and operation are available to tailor the detector to its respective application. Part of this concept is a programmable analog signal processor, which has been developed for the readout of the CCD signals. The electronic noise of the new detector has a value of only 2 electrons equivalent noise charge (ENC), which is less than half of the figure achieved for the XMM-Newton-type pnCCD. The energy resolution for the Mn-K α line at 5.9 keV is approximately 130 eV FWHM. We have close to 100% quantum efficiency for both low- and high-energy photon detection (e.g. the C-K line at 277 eV, and the Ge-K α line at 10 keV, respectively). Very high frame rates of 1000 images/s have been achieved due to the ultra-fast readout accomplished by the parallel architecture of the pnCCD and the analog signal processor. Excellent spectroscopic performance is shown even at the relatively high operating temperature of −25 °C that can be achieved by a Peltier cooler. The applications of the low-noise and fast pnCCD detector are not limited to the detection of X-rays. With an anti-reflective coating deposited on the photon entrance window, we achieve high quantum efficiency also for near-infrared and optical photons. A novel type of pnCCD is in preparation, which allows single optical photon counting. This feature is accomplished by implementation of an avalanche-type amplifier in the pnCCD concept.
[1]
Stefan Hofer,et al.
The x-ray telescope ROSITA on its way to orbit
,
2004,
SPIE Astronomical Telescopes + Instrumentation.
[2]
Elmar Pfeffermann,et al.
The European Photon Imaging Camera on XMM-Newton: The pn-CCD camera
,
2001
.
[3]
Peter Holl,et al.
High-speed frame store CCD for use in optical and near-infrared astronomy
,
2000,
Astronomical Telescopes and Instrumentation.
[4]
R. Hartmann,et al.
Electron emission channeling spectroscopy using X-ray CCD detectors
,
2003
.
[5]
Norbert Meidinger,et al.
A high-speed pnCCD detector system for optical applications
,
2006
.
[6]
Elmar Pfeffermann,et al.
CCD-detector development for the DUO and the ROSITA missions
,
2004,
SPIE Astronomical Telescopes + Instrumentation.
[7]
B. Niemann,et al.
The new scanning transmission X-ray microscope at BESSY II
,
2000
.
[8]
Norbert Meidinger,et al.
Radiation damage effects on the EPIC PN-CCD detector aboard XMM-Newton
,
2004
.
[9]
P. Holl,et al.
Novel digital K-edge imaging system with transition radiation from an 855-MeV electron beam
,
2000
.
[10]
Herbert Walther,et al.
High-order harmonic generation at a repetition rate of 100 kHz
,
2003
.
[11]
Lothar Strüder,et al.
An application of space technology to the terrestrial search for axions: the X-ray mirror telescope at CAST
,
2004
.
[12]
G. G. Stokes.
"J."
,
1890,
The New Yale Book of Quotations.